Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma

被引:3
作者
Kampmeier, J [1 ]
Eisert, B [1 ]
Buchwald, HJ [1 ]
Lang, GK [1 ]
Lang, GE [1 ]
机构
[1] Univ Ulm, Augenklin Poliklin, D-89075 Ulm, Germany
关键词
glaucoma; perimetry; FDP; HFA;
D O I
10.1055/s-2001-13075
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To compare frequency doubling perimetry (FDP) versus standard automated perimetry in glaucoma. To evaluate the reproducibility of both methods. Patients and Methods: All the patients were tested (full threshold test) twice with both FDP (N-30) and Humphrey Field Analyzer II Model 750 (HFA) (30-2 procedures) in random sequence, within one day. The parameters mean deviation (MD), pattern standard deviation (PSD) and measured thresholds per quadrant and center areas were evaluated for FDP/HFA comparison in 45 glaucoma patients. The same parameters were used for testing the reproducibility of FDP (n = 46) and HFA (N = 39). Additionally, the center and each quadrant area were checked for any deviation in the total deviation probability plots. For statistical analysis Kappa coefficients and Bland/Altman plots were used. Results: An average MD (FDP vs HFA) of -7.3+/-5.8 dB vs -8.9 +/- 7.6 dB and PSD of 6.9 +/- 2.4 dB vs 6.5 +/- 3.6 dB were found. Kappa coefficients denote marginal accordance (kappa: 0.11-0.38) for area deviations. In a total of 225 areas HFA detected 191 deviations and FDP 165. HFA measured more negative deviation compared with FDP in the case of MD < -15 dB. The reproducibility was 0.98 (MD) and 0.92 (PSD) for FDP and 0.98 (MD) and 0.95 (PSD) for HFA (95% confidence interval). Conclusions: There was great conformity between FDP and HFA in glaucoma patients. HFA detected more deviations in the total deviation probability plots than FDP. There was a high reproducibility of both methods. FDP is an appropriate tool for detecting visual field loss in glaucoma patients.
引用
收藏
页码:157 / 167
页数:11
相关论文
共 50 条
  • [21] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Folkert K. Horn
    Nina Wakili
    Anselm M. Jünemann
    Matthias Korth
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 658 - 665
  • [22] A comparison of diagnostic protocols for interpretation of frequency doubling perimetry visual fields in glaucoma
    Landers, John
    Sharma, Alok
    Goldberg, Ivan
    Graham, Stuart
    JOURNAL OF GLAUCOMA, 2006, 15 (04) : 310 - 314
  • [23] Long-term fluctuation of standard automatic perimetry, pulsar Perimetry and frequency-doubling technology in early glaucoma diagnosis
    Gonzalez-Hernandez, M.
    de la Rosa, M. Gonzalez
    de la Vega, R. Rodriguez
    Hernandez-Vidal, A.
    OPHTHALMIC RESEARCH, 2007, 39 (06) : 338 - 343
  • [24] Glaucoma Monitoring with Frequency Doubling Perimetry in the Groningen Longitudinal Glaucoma Study
    Wesselink, Christiaan
    Jansonius, Nomdo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [25] New perimetric techniques - A comparison between rarebit and frequency doubling technology perimetry in normal subjects and glaucoma patients
    Martin, L
    Wanger, P
    JOURNAL OF GLAUCOMA, 2004, 13 (04) : 268 - 272
  • [26] A comparison of short wavelength automated perimetry with frequency doubling perimetry for the early detection of visual field loss in ocular hypertension
    Landers, J
    Goldberg, I
    Graham, S
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 28 (04) : 248 - 252
  • [27] Standard automated perimetry and algorithms for monitoring glaucoma progression
    Scuderi, G. L.
    Cesareo, M.
    Perdicchi, A.
    Recupero, S. M.
    GLAUCOMA: AN OPEN WINDOW TO NEURODEGENERATION AND NEUROPROTECTION, 2008, 173 : 77 - 99
  • [28] Repeatability of Automated Perimetry: A Comparison between Standard Automated Perimetry with Stimulus Size III and V, Matrix, and Motion Perimetry
    Wall, Michael
    Woodward, Kimberly R.
    Doyle, Carrie K.
    Artes, Paul H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (02) : 974 - 979
  • [29] Circular Contrast Perimetry via Web Application A Patient Appraisal and Comparison to Standard Automated Perimetry
    Meyerov, Joshua
    Deng, Yuanchen
    Busija, Lazar
    Skalicky, Simon E.
    OPHTHALMOLOGY SCIENCE, 2022, 2 (03):
  • [30] Eye Movement Perimetry and Frequency Doubling Perimetry: clinical performance and patient preference during glaucoma screening
    Meethal, Najiya Sundus Kadavath
    Pel, Johan J. M.
    Mazumdar, Deepmala
    Asokan, Rashima
    Panday, Manish
    van der Steen, Johannes
    George, Ronnie
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (06) : 1277 - 1287