Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma

被引:3
作者
Kampmeier, J [1 ]
Eisert, B [1 ]
Buchwald, HJ [1 ]
Lang, GK [1 ]
Lang, GE [1 ]
机构
[1] Univ Ulm, Augenklin Poliklin, D-89075 Ulm, Germany
关键词
glaucoma; perimetry; FDP; HFA;
D O I
10.1055/s-2001-13075
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To compare frequency doubling perimetry (FDP) versus standard automated perimetry in glaucoma. To evaluate the reproducibility of both methods. Patients and Methods: All the patients were tested (full threshold test) twice with both FDP (N-30) and Humphrey Field Analyzer II Model 750 (HFA) (30-2 procedures) in random sequence, within one day. The parameters mean deviation (MD), pattern standard deviation (PSD) and measured thresholds per quadrant and center areas were evaluated for FDP/HFA comparison in 45 glaucoma patients. The same parameters were used for testing the reproducibility of FDP (n = 46) and HFA (N = 39). Additionally, the center and each quadrant area were checked for any deviation in the total deviation probability plots. For statistical analysis Kappa coefficients and Bland/Altman plots were used. Results: An average MD (FDP vs HFA) of -7.3+/-5.8 dB vs -8.9 +/- 7.6 dB and PSD of 6.9 +/- 2.4 dB vs 6.5 +/- 3.6 dB were found. Kappa coefficients denote marginal accordance (kappa: 0.11-0.38) for area deviations. In a total of 225 areas HFA detected 191 deviations and FDP 165. HFA measured more negative deviation compared with FDP in the case of MD < -15 dB. The reproducibility was 0.98 (MD) and 0.92 (PSD) for FDP and 0.98 (MD) and 0.95 (PSD) for HFA (95% confidence interval). Conclusions: There was great conformity between FDP and HFA in glaucoma patients. HFA detected more deviations in the total deviation probability plots than FDP. There was a high reproducibility of both methods. FDP is an appropriate tool for detecting visual field loss in glaucoma patients.
引用
收藏
页码:157 / 167
页数:11
相关论文
共 50 条
  • [11] Glaucoma progression detection with frequency doubling technology (FDT) compared to standard automated perimetry (SAP) in the Groningen Longitudinal Glaucoma Study
    Wesselink, Christiaan
    Jansonius, Nomdo M.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2017, 37 (05) : 594 - 601
  • [12] Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients
    Hirasawa, Kazunori
    Takahashi, Natsumi
    Satou, Tsukasa
    Kasahara, Masayuki
    Matsumura, Kazuhiro
    Shoji, Nobuyuki
    CURRENT EYE RESEARCH, 2017, 42 (08) : 1160 - 1168
  • [13] Comparison of the Variability of Standard Automated Perimetry between Preperimetric Glaucoma Patients and Normal Controls
    Kim, Sung In
    Park, Hae-Young Lopilly
    Park, Chan Kee
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2018, 59 (01): : 44 - 49
  • [14] Relationship between indices of Humphrey perimetry and Frequency Doubling Technology perimetry in glaucoma
    Fukushima, A
    Shirakashi, M
    Yaoeda, K
    Funaki, S
    Funaki, H
    Ofuchi, N
    Abe, H
    JOURNAL OF GLAUCOMA, 2004, 13 (02) : 114 - 119
  • [15] Glaucoma detection with frequency doubling perimetry and short-wave length perimetry
    Horn, Folkert K.
    Brenning, Alexander
    Juenemann, Anselm G.
    Lausen, Berthold
    JOURNAL OF GLAUCOMA, 2007, 16 (04) : 363 - 371
  • [16] Prediction of visual field defects on standard automated perimetry by screening C-20-1 frequency doubling technology perimetry
    Kamantigue, MEG
    Joson, PJ
    Chen, PP
    JOURNAL OF GLAUCOMA, 2006, 15 (01) : 35 - 39
  • [17] Rarebit Perimetry for Bedside Testing: Comparison With Standard Automated Perimetry
    Houston, Samuel K. Steven
    Weber, Eric D.
    Koga, Sebastian F.
    Newman, Steven A.
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2010, 30 (03) : 243 - 247
  • [18] Comparison of Glaucoma Detection Performance of Binocular Perimetry Screening Program Using imo Perimetry With Frequency Doubling Technology
    Nishijima, Euido
    Hosaka, Daisuke
    Ogawa, Shumpei
    Itoh, Yoshinori
    Noro, Takahiko
    Okude, Sachiyo
    Sano, Kei
    Yoshikawa, Keiji
    Tatemichi, Masayuki
    Nakano, Tadashi
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (08):
  • [19] Effect of yellow-tinted intraocular lens on standard automated perimetry and short wavelength automated perimetry in patients with glaucoma
    Nilforushan, Naveed
    Parsamanesh, Mohammad
    Yu, Fei
    Nassiri, Nariman
    Miraftabi, Arezoo
    Coleman, Anne L.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2014, 21 (03) : 216 - 219
  • [20] Octopus 900 Automated Kinetic Perimetry versus Standard Automated Static Perimetry in Glaucoma Practice
    Rowe, Fiona J.
    Czanner, Gabriela
    Somerville, Tobi
    Sood, Ishaana
    Sood, Devindra
    CURRENT EYE RESEARCH, 2021, 46 (01) : 83 - 95