Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma

被引:3
作者
Kampmeier, J [1 ]
Eisert, B [1 ]
Buchwald, HJ [1 ]
Lang, GK [1 ]
Lang, GE [1 ]
机构
[1] Univ Ulm, Augenklin Poliklin, D-89075 Ulm, Germany
关键词
glaucoma; perimetry; FDP; HFA;
D O I
10.1055/s-2001-13075
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To compare frequency doubling perimetry (FDP) versus standard automated perimetry in glaucoma. To evaluate the reproducibility of both methods. Patients and Methods: All the patients were tested (full threshold test) twice with both FDP (N-30) and Humphrey Field Analyzer II Model 750 (HFA) (30-2 procedures) in random sequence, within one day. The parameters mean deviation (MD), pattern standard deviation (PSD) and measured thresholds per quadrant and center areas were evaluated for FDP/HFA comparison in 45 glaucoma patients. The same parameters were used for testing the reproducibility of FDP (n = 46) and HFA (N = 39). Additionally, the center and each quadrant area were checked for any deviation in the total deviation probability plots. For statistical analysis Kappa coefficients and Bland/Altman plots were used. Results: An average MD (FDP vs HFA) of -7.3+/-5.8 dB vs -8.9 +/- 7.6 dB and PSD of 6.9 +/- 2.4 dB vs 6.5 +/- 3.6 dB were found. Kappa coefficients denote marginal accordance (kappa: 0.11-0.38) for area deviations. In a total of 225 areas HFA detected 191 deviations and FDP 165. HFA measured more negative deviation compared with FDP in the case of MD < -15 dB. The reproducibility was 0.98 (MD) and 0.92 (PSD) for FDP and 0.98 (MD) and 0.95 (PSD) for HFA (95% confidence interval). Conclusions: There was great conformity between FDP and HFA in glaucoma patients. HFA detected more deviations in the total deviation probability plots than FDP. There was a high reproducibility of both methods. FDP is an appropriate tool for detecting visual field loss in glaucoma patients.
引用
收藏
页码:157 / 167
页数:11
相关论文
共 50 条
  • [1] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Stefan Serguhn
    Detlev Spiegel
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 351 - 355
  • [2] The Groningen Longitudinal Glaucoma Study. II. A prospective comparison of frequency doubling perimetry, the GDx nerve fibre analyser and standard automated perimetry in glaucoma suspect patients
    Jansonius, Nomdo M.
    Heeg, Govert P.
    ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 429 - 432
  • [3] Frequency Doubling Technology perimetry and standard automated perimetry in migraine
    Harle, DE
    Evans, BJW
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (03) : 233 - 239
  • [4] Relationship between second-generation frequency doubling technology and standard automated perimetry in patients with glaucoma
    Zarkovic, Andrea
    Mora, Justin
    McKelvie, James
    Gamble, Greg
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (09) : 808 - 811
  • [5] Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology
    Genichiro Takahashi
    Shaban Demirel
    Chris A. Johnson
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 797 - 803
  • [6] Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology
    Takahashi, Genichiro
    Demirel, Shaban
    Johnson, Chris A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (04) : 797 - 803
  • [7] Frequency doubling perimetry in glaucoma
    Thomas, R
    Bhat, S
    Muliyil, JP
    Parikh, R
    George, R
    JOURNAL OF GLAUCOMA, 2002, 11 (01) : 46 - 50
  • [8] Short-wavelength automated perimetry and frequency-doubling technology perimetry in glaucoma
    Fogagnolo, Paolo
    Rossetti, Luca
    Ranno, Stefano
    Ferreras, Antonio
    Orzalesi, Nicola
    GLAUCOMA: AN OPEN WINDOW TO NEURODEGENERATION AND NEUROPROTECTION, 2008, 173 : 101 - 124
  • [9] A Comparison of Catch Trial Methods Used in Standard Automated Perimetry in Glaucoma Patients
    Wall, Michael
    Doyle, Carrie K.
    Brito, Caridad F.
    Woodward, Kimberly R.
    Johnson, Chris A.
    JOURNAL OF GLAUCOMA, 2008, 17 (08) : 626 - 630
  • [10] Online Circular Contrast Perimetry: A Comparison to Standard Automated Perimetry
    Meyerov, Joshua
    Deng, Yuanchen
    Busija, Lazar
    Bigirimana, Deus
    Skalicky, Simon E.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2023, 12 (01): : 4 - 15