Deep learning-based attenuation correction in the absence of structural information for whole-body positron emission tomography imaging

被引:108
作者
Dong, Xue [1 ]
Lei, Yang [1 ]
Wang, Tonghe [1 ]
Higgins, Kristin [1 ,2 ]
Liu, Tian [1 ,2 ]
Curran, Walter J. [1 ,2 ]
Mao, Hui [2 ,3 ]
Nye, Jonathon A. [3 ]
Yang, Xiaofeng [1 ,2 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
[3] Emory Univ, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
基金
美国国家卫生研究院;
关键词
PET; attenuation correction; deep learning; QUANTITATIVE-EVALUATION; GUIDED ATTENUATION; PEDIATRIC CT; PET/MRI; PET; ATLAS; QUANTIFICATION; RECONSTRUCTION; SEGMENTATION; IMPACT;
D O I
10.1088/1361-6560/ab652c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Deriving accurate structural maps for attenuation correction (AC) of whole-body positron emission tomography (PET) remains challenging. Common problems include truncation, inter-scan motion, and erroneous transformation of structural voxel-intensities to PET mu-map values (e.g. modality artifacts, implanted devices, or contrast agents). This work presents a deep learning-based attenuation correction (DL-AC) method to generate attenuation corrected PET (AC PET) from non-attenuation corrected PET (NAC PET) images for whole-body PET imaging, without the use of structural information. 3D patch-based cycle-consistent generative adversarial networks (CycleGAN) is introduced to include NAC-PET-to-AC-PET mapping and inverse mapping from AC PET to NAC PET, which constrains NAC-PET-to-AC-PET mapping to be closer to one-to-one mapping. Since NAC PET images share similar anatomical structures to the AC PET image but lack contrast information, residual blocks, which aim to learn the differences between NAC PET and AC PET, are used to construct generators of CycleGAN. After training, patches from NAC PET images were fed into NAC-PET-to-AC-PET mapping to generate DL-AC PET patches. DL-AC PET image was then reconstructed through patch fusion. We conducted a retrospective study on 55 datasets of whole-body PET/CT scans to evaluate the proposed method. In comparing DL-AC PET with original AC PET, average mean error (ME) and normalized mean square error (NMSE) of the whole-body were 0.62% +/- 1.26% and 0.72% +/- 0.34%. The average intensity changes measured on sequential PET images with AC and DL-AC on both normal tissues and lesions differ less than 3%. There was no significant difference of the intensity changes between AC and DL-AC PET, which demonstrate DL-AC PET images generated by the proposed DL-AC method can reach a same level to that of original AC PET images. The method demonstrates excellent quantification accuracy and reliability and is applicable to PET data collected on a single PET scanner or hybrid platform with computed tomography (PET/CT) or magnetic resonance imaging (PET/MRI).
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Bone Metastases Are Measurable: The Role of Whole-Body MRI and Positron Emission Tomography
    Oprea-Lager, Daniela E.
    Cysouw, Matthijs C. F.
    Boellaard, Ronald
    Deroose, Christophe M.
    de Geus-Oei, Lioe-Fee
    Lopci, Egesta
    Bidaut, Luc
    Herrmann, Ken
    Fournier, Laure S.
    Baeuerle, Tobias
    deSouza, Nandita M.
    Lecouvet, Frederic E.
    [J]. FRONTIERS IN ONCOLOGY, 2021, 11
  • [42] Whole-Body Positron Emission Tomography-Magnetic Resonance in Breast Cancer
    Sher, Andrew
    Valls, Laia
    Muzic, Raymond F., Jr.
    Plecha, Donna
    Avril, Norbert
    [J]. SEMINARS IN ROENTGENOLOGY, 2014, 49 (04) : 313 - 320
  • [43] Verification of image quality and quantification in whole-body positron emission tomography with continuous bed motion
    Yamamoto, Hideo
    Takemoto, Shota
    Maebatake, Akira
    Karube, Shuhei
    Yamashiro, Yuki
    Nakanishi, Atsushi
    Murakami, Koji
    [J]. ANNALS OF NUCLEAR MEDICINE, 2019, 33 (04) : 288 - 294
  • [44] A deep learning-based auto-segmentation system for organs-at-risk on whole-body computed tomography images for radiation therapy
    Chen, Xuming
    Sun, Shanlin
    Bai, Narisu
    Han, Kun
    Liu, Qianqian
    Yao, Shengyu
    Tang, Hao
    Zhang, Chupeng
    Lu, Zhipeng
    Huang, Qian
    Zhao, Guoqi
    Xu, Yi
    Chen, Tingfeng
    Xie, Xiaohui
    Liu, Yong
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 160 : 175 - 184
  • [45] Simultaneous Positron Emission Tomography/Magnetic Resonance Imaging for Whole-Body Staging in Patients With Recurrent Gynecological Malignancies of the Pelvis A Comparison to Whole-Body Magnetic Resonance Imaging Alone
    Grueneisen, Johannes
    Beiderwellen, Karsten
    Heusch, Philipp
    Gratz, Marcel
    Schulze-Hagen, Antonia
    Heubner, Martin
    Kinner, Sonja
    Forsting, Michael
    Lauenstein, Thomas
    Ruhlmann, Verena
    Umutlu, Lale
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (12) : 808 - 815
  • [46] Hidden Markov model based attenuation correction for positron emission tomography
    Anderson, JMM
    Srinivasan, R
    Mair, BA
    Votaw, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2103 - 2111
  • [47] Informativeness of whole-body diffusion-weighted magnetic resonance imaging and positron emission tomography with computed tomography in follicular lymphoma
    Nesterova, E. S.
    Yatsyk, G. A.
    Lutsik, N. S.
    Kravchenko, S. K.
    Sudarikov, A. B.
    Krasilonikova, I., V
    Gemdzhian, E. G.
    Kovrigina, A. M.
    [J]. TERAPEVTICHESKII ARKHIV, 2020, 92 (07) : 55 - 62
  • [48] Deep learning-based attenuation correction for brain PET with various radiotracers
    Fumio Hashimoto
    Masanori Ito
    Kibo Ote
    Takashi Isobe
    Hiroyuki Okada
    Yasuomi Ouchi
    [J]. Annals of Nuclear Medicine, 2021, 35 : 691 - 701
  • [49] Deep learning-based attenuation correction for brain PET with various radiotracers
    Hashimoto, Fumio
    Ito, Masanori
    Ote, Kibo
    Isobe, Takashi
    Okada, Hiroyuki
    Ouchi, Yasuomi
    [J]. ANNALS OF NUCLEAR MEDICINE, 2021, 35 (06) : 691 - 701
  • [50] MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods
    Hofmann, Matthias
    Bezrukov, Ilja
    Mantlik, Frederic
    Aschoff, Philip
    Steinke, Florian
    Beyer, Thomas
    Pichler, Bernd J.
    Schoelkopf, Bernhard
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (09) : 1392 - 1399