Deep learning-based attenuation correction in the absence of structural information for whole-body positron emission tomography imaging

被引:107
|
作者
Dong, Xue [1 ]
Lei, Yang [1 ]
Wang, Tonghe [1 ]
Higgins, Kristin [1 ,2 ]
Liu, Tian [1 ,2 ]
Curran, Walter J. [1 ,2 ]
Mao, Hui [2 ,3 ]
Nye, Jonathon A. [3 ]
Yang, Xiaofeng [1 ,2 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
[3] Emory Univ, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 05期
基金
美国国家卫生研究院;
关键词
PET; attenuation correction; deep learning; QUANTITATIVE-EVALUATION; GUIDED ATTENUATION; PEDIATRIC CT; PET/MRI; PET; ATLAS; QUANTIFICATION; RECONSTRUCTION; SEGMENTATION; IMPACT;
D O I
10.1088/1361-6560/ab652c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Deriving accurate structural maps for attenuation correction (AC) of whole-body positron emission tomography (PET) remains challenging. Common problems include truncation, inter-scan motion, and erroneous transformation of structural voxel-intensities to PET mu-map values (e.g. modality artifacts, implanted devices, or contrast agents). This work presents a deep learning-based attenuation correction (DL-AC) method to generate attenuation corrected PET (AC PET) from non-attenuation corrected PET (NAC PET) images for whole-body PET imaging, without the use of structural information. 3D patch-based cycle-consistent generative adversarial networks (CycleGAN) is introduced to include NAC-PET-to-AC-PET mapping and inverse mapping from AC PET to NAC PET, which constrains NAC-PET-to-AC-PET mapping to be closer to one-to-one mapping. Since NAC PET images share similar anatomical structures to the AC PET image but lack contrast information, residual blocks, which aim to learn the differences between NAC PET and AC PET, are used to construct generators of CycleGAN. After training, patches from NAC PET images were fed into NAC-PET-to-AC-PET mapping to generate DL-AC PET patches. DL-AC PET image was then reconstructed through patch fusion. We conducted a retrospective study on 55 datasets of whole-body PET/CT scans to evaluate the proposed method. In comparing DL-AC PET with original AC PET, average mean error (ME) and normalized mean square error (NMSE) of the whole-body were 0.62% +/- 1.26% and 0.72% +/- 0.34%. The average intensity changes measured on sequential PET images with AC and DL-AC on both normal tissues and lesions differ less than 3%. There was no significant difference of the intensity changes between AC and DL-AC PET, which demonstrate DL-AC PET images generated by the proposed DL-AC method can reach a same level to that of original AC PET images. The method demonstrates excellent quantification accuracy and reliability and is applicable to PET data collected on a single PET scanner or hybrid platform with computed tomography (PET/CT) or magnetic resonance imaging (PET/MRI).
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Feasibility of Deep Learning-Guided Attenuation and Scatter Correction of Whole-Body 68Ga-PSMA PET Studies in the Image Domain
    Mostafapour, Samaneh
    Gholamiankhah, Faeze
    Dadgar, Habibollah
    Arabi, Hossein
    Zaidi, Habib
    CLINICAL NUCLEAR MEDICINE, 2021, 46 (08) : 609 - 615
  • [22] Deep Learning-Based Positron Emission Tomography Molecular Imaging in the Assessment of Cognitive Dysfunction in Patients with Epilepsy
    Tuerxun, Mayila
    Yin, Lixin
    Chen, Huiqun
    Lin, Jingqian
    SCIENTIFIC PROGRAMMING, 2021, 2021 (2021)
  • [23] SIMULTANEOUS EMISSION AND TRANSMISSION MEASUREMENTS FOR ATTENUATION CORRECTION IN WHOLE-BODY PET
    MEIKLE, SR
    BAILEY, DL
    HOOPER, PK
    EBERL, S
    HUTTON, BF
    JONES, WF
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (09) : 1680 - 1688
  • [24] Whole-body positron emission tomography in clinical oncology: comparison between attenuation-corrected and uncorrected images
    Bengel, FM
    Ziegler, SI
    Avril, N
    Weber, W
    Laubenbacher, C
    Schwaiger, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (09): : 1091 - 1098
  • [25] Whole-body positron emission tomography in clinical oncology: Comparison between attenuation-corrected and uncorrected images
    Frank M. Bengel
    Sibylle I. Ziegler
    Norbert Avril
    Wolfgang Weber
    Christian Laubenbacher
    Markus Schwaiger
    European Journal of Nuclear Medicine, 1997, 24 (9) : 1091 - 1098
  • [26] Deep learning-based image reconstruction and post-processing methods in positron emission tomography for low-dose imaging and resolution enhancement
    Pain, Cameron Dennis
    Egan, Gary F.
    Chen, Zhaolin
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (09) : 3098 - 3118
  • [27] Magnetic resonance imaging-guided attenuation correction in whole-body PET/MRI using a sorted atlas approach
    Arabi, Hossein
    Zaidi, Habib
    MEDICAL IMAGE ANALYSIS, 2016, 31 : 1 - 15
  • [28] Deep learning-based attenuation correction for whole-body PET - a multi-tracer study with 18F-FDG, 68 Ga-DOTATATE, and 18F-Fluciclovine
    Toyonaga, Takuya
    Shao, Dan
    Shi, Luyao
    Zhang, Jiazhen
    Revilla, Enette Mae
    Menard, David
    Ankrah, Joseph
    Hirata, Kenji
    Chen, Ming-Kai
    Onofrey, John A.
    Lu, Yihuan
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (09) : 3086 - 3097
  • [29] Magnetic Resonance-Based Motion Correction for Positron Emission Tomography Imaging
    Ouyang, Jinsong
    Li, Quanzheng
    El Fakhri, Georges
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 60 - 67
  • [30] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    David Izquierdo-Garcia
    Stephen J. Sawiak
    Karin Knesaurek
    Jagat Narula
    Valentin Fuster
    Joseph Machac
    Zahi A. Fayad
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1574 - 1584