Is Long-Axis View Superior to Short-Axis View in Ultrasound-Guided Central Venous Catheterization?

被引:69
作者
Vogel, Jody A. [1 ,2 ]
Haukoos, Jason S. [1 ,2 ,3 ]
Erickson, Catherine L. [4 ]
Liao, Michael M. [5 ]
Theoret, Jonathan [6 ]
Sanz, Geoffrey E. [7 ]
Kendall, John [1 ,2 ]
机构
[1] Denver Hlth Med Ctr, Dept Emergency Med, Denver, CO 80204 USA
[2] Univ Colorado, Sch Med, Dept Emergency Med, Aurora, CO USA
[3] Colorado Sch Publ Hlth, Dept Epidemiol, Aurora, CO USA
[4] Oregon Hlth & Sci Univ, Dept Emergency Med, Portland, OR 97201 USA
[5] North Suburban Med Ctr, Dept Emergency Med, Thornton, CO USA
[6] Univ Alberta, Dept Emergency Med, Edmonton, AB, Canada
[7] Queens Univ, Dept Emergency Med, Kingston, ON, Canada
基金
美国医疗保健研究与质量局; 美国国家卫生研究院;
关键词
central venous access; central venous catheter; internal jugular vein; subclavian vein; ultrasonography; ultrasound; INTERNAL JUGULAR-VEIN; LANDMARK TECHNIQUE; VASCULAR ACCESS; CANNULATION; GUIDANCE; PLACEMENT; COMPLICATIONS; TRIAL; METAANALYSIS; INFECTIONS;
D O I
10.1097/CCM.0000000000000823
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate whether using long-axis or short-axis view during ultrasound-guided internal jugular and subclavian central venous catheterization results in fewer skin breaks, decreased time to cannulation, and fewer posterior wall penetrations. Design: Prospective, randomized crossover study. Setting: Urban emergency department with approximate annual census of 60,000. Subjects: Emergency medicine resident physicians at the Denver Health Residency in Emergency Medicine, a postgraduate year 1-4 training program. Interventions: Resident physicians blinded to the study hypothesis used ultrasound guidance to cannulate the internal jugular and subclavian of a human torso mannequin using the long-axis and short-axis views at each site. Measurements and Main Results: An ultrasound fellow recorded skin breaks, redirections, and time to cannulation. An experienced ultrasound fellow or attending used a convex 8-4 MHz transducer during cannulation to monitor the needle path and determine posterior wall penetration. Generalized linear mixed models with a random subject effect were used to compare time to cannulation, number of skin breaks and redirections, and posterior wall penetration of the long axis and short axis at each cannulation site. Twenty-eight resident physicians participated: eight postgraduate year 1, eight postgraduate year 2, five postgraduate year 3, and seven postgraduate year 4. The median (interquartile range) number of total internal jugular central venous catheters placed was 27 (interquartile range, 9-42) and subclavian was six catheters (interquartile range, 2-20). The median number of previous ultrasound-guided internal jugular catheters was 25 (interquartile range, 9-40), and ultrasound-guided subclavian catheters were three (interquartile range, 0-5). The long-axis view was associated with a significant decrease in the number of redirections at the internal jugular and subclavian sites, relative risk 0.4 (95% CI, 0.2-0.9) and relative risk 0.5 (95% CI, 0.3-0.7), respectively. There was no significant difference in the number of skin breaks between the long axis and short axis at the subclavian and internal jugular sites. The long-axis view for subclavian was associated with decreased time to cannulation; there was no significant difference in time between the short-axis and long-axis views at the internal jugular site. The prevalence of posterior wall penetration was internal jugular short axis 25%, internal jugular long axis 21%, subclavian short axis 64%, and subclavian long axis 39%. The odds of posterior wall penetration were significantly less in the subclavian long axis (odds ratio, 0.3; 95% CI, 0.1-0.9). Conclusions: The long-axis view for the internal jugular was more efficient than the short-axis view with fewer redirections. The long-axis view for subclavian central venous catheterization was also more efficient with decreased time to cannulation and fewer redirections. The long-axis approach to subclavian central venous catheterization is also associated with fewer posterior wall penetrations. Using the long-axis view for subclavian central venous catheterization and avoiding posterior wall penetrations may result in fewer central venous catheter-related complications.
引用
收藏
页码:832 / 839
页数:8
相关论文
共 50 条
[21]   Ultrasound-guided short-axis out-of-plane vs. long-axis in-plane technique for radial artery catheterization: an updated meta-analysis of randomized controlled trials [J].
Wang, H-H ;
Wang, J-J ;
Chen, W-T .
EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2022, 26 (06) :1914-1922
[22]   A randomized clinical trial of ultrasound-guided infra-clavicular cannulation of the subclavian vein in cardiac surgical patients: short-axis versus long-axis approach [J].
Antonella Vezzani ;
Tullio Manca ;
Claudia Brusasco ;
Gregorio Santori ;
Luca Cantadori ;
Andrea Ramelli ;
Gianluca Gonzi ;
Francesco Nicolini ;
Tiziano Gherli ;
Francesco Corradi .
Intensive Care Medicine, 2017, 43 :1594-1601
[23]   Ultrasound-guided central venous catheterization: A review of the relevant anatomy, technique, complications, and anatomical variations [J].
Hoffman, Taryn ;
Du Plessis, Maira ;
Prekupec, Matthew P. ;
Gielecki, Jerzy ;
Zurada, Anna ;
Tubbs, R. Shane ;
Loukas, Marios .
CLINICAL ANATOMY, 2017, 30 (02) :237-250
[24]   Syringe-Free, Long-Axis in-Plane Versus Short-Axis Classic out-of-Plane Approach for Ultrasound-Guided Internal Jugular Vein Catheter Placement in Critically Ill Children: A Prospective Randomized Study [J].
Keskin, Halil ;
Keskin, Filiz ;
Aydin, Pelin ;
Guler, Muhammet Akif ;
Ahiskalioglu, Ali .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (07) :2094-2099
[25]   Comparison of short-axis out-of-plane versus long-axis in-plane ultrasound-guided radial arterial cannulation in adult patients: a randomized controlled trial [J].
Sameer Sethi ;
Souvik Maitra ;
Vikas Saini ;
Tanvir Samra ;
S. K. Malhotra .
Journal of Anesthesia, 2017, 31 :89-94
[26]   Comparison of dynamic needle tip positioning versus conventional long-axis in-plane techniques for ultrasound-guided internal jugular venous catheterization: a randomized controlled trial [J].
Lee, Seohee ;
Chang, Jee-Eun ;
Oh, Yoomin ;
Yang, Hyo-Jun ;
Bae, Jinyoung ;
Cho, Youn-Joung ;
Jeon, Yunseok ;
Nam, Karam ;
Kim, Tae-Kyong .
MINERVA ANESTESIOLOGICA, 2021, 87 (03) :294-301
[27]   Comparison between the long-axis in-plane and short-axis out-of-plane approaches for ultrasound-guided arterial cannulation: a meta-analysis and systematic review [J].
Cao, Lei ;
Tan, Yu-ting ;
Wei, Ting ;
Li, Hong .
BMC ANESTHESIOLOGY, 2023, 23 (01)
[28]   Comparison of Success Rates of Different Methods of Ultrasound-Guided Radial Artery Cannulation (Short-Axis and Long-Axis Methods) Against the Traditional Palpatory Method: A Prospective Randomized Study [J].
Rajasekar, Mounica ;
Sukumar, Senthilkumar ;
Selvaraj, Venkatesh .
TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2022, 50 (01) :52-58
[29]   Comparison of short and long axis ultrasound-guided approaches to internal jugular vein puncture: a meta-analysis [J].
Zhang, Jian ;
Wang, Xiaohan ;
Miao, Shuai ;
Shi, Mengzhu ;
Wang, Guanglei ;
Tu, Qing .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (09) :4069-4082
[30]   Combined Approach Versus 2 Conventional Approaches in Ultrasound-Guided Central Venous Catheterization: A Randomized Controlled Trial [J].
Takeshita, Jun ;
Nishiyama, Kei ;
Fukumoto, Atsushi ;
Shime, Nobuaki .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (11) :2979-2984