Validation of the simulation of solar air collector prototypes

被引:0
|
作者
Villanueva Vega, E. [1 ]
Noh-Pat, F. [1 ]
机构
[1] Univ Autonoma Baja California, Tijuana 21500, Mexico
来源
2013 ISES SOLAR WORLD CONGRESS | 2014年 / 57卷
关键词
Solar air collector; prototype; mathematical model; collector block; transient; heat flux; implementation; simulation; software; Matlab; Simulink; validation;
D O I
10.1016/j.egypro.2014.10.237
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The solar air systems can be appropriated into constructions due to the easy integration of air collectors in building facades, either into walls and roofs or by replacing one of them. There are several types of solar air collectors, which differ from each other on how the cover, absorber and airflow pattern are laid out in the collector. It is important to know the collector performance in order to design other system elements. Designs of solar air collectors and their respective models can be found in some solar engineering books. The model equations allow measuring the collector performance at a particular time. However, it is necessary to know some state variables of the collector such as the collector element temperatures, and heat transfer coefficients. It is important to emphasize that the collector state variables are changing with time due to the environmental effects. This study deals with the mathematical models, the implementations and the validations of numerical simulation for three experimental prototypes of solar air collector. The Solar-Institute Julich of Germany developed the prototypes. In a general form the mathematical one-dimensional transient model of heat flux of each solar air collector is presented. Besides, the implementation of the collector models in the MATLAB-Simulink software is described. As a result of the validation of experimental data, the mathematical models and numerical implementations are able to estimate the air temperature inside of the collector. Average absolute error between integrals of simulated and measured temperatures reached hardly 1.2 degrees C. In general, the three solar air collector models had a very good performance. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:2295 / 2304
页数:10
相关论文
共 50 条
  • [1] Validation of unglazed transpired solar collector assisted air source heat pump simulation model
    Janusevicius, Karolis
    Streckiene, Giedre
    Bielskus, Juozas
    Martinaitis, Vytautas
    INTERNATIONAL SCIENTIFIC CONFERENCE - ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, CONECT 2015, 2016, 95 : 167 - 174
  • [2] Performance analysis and comparison of glazed and unglazed solar air collector
    Dabra, Vishal
    Yadav, Avadhesh
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2020, 22 (02) : 863 - 881
  • [3] Uncertainty analysis and experimental validation of solar parabolic trough collector simulation model
    Akello, Philip O. O.
    Saoke, Churchil O.
    Kamau, Joseph N.
    Ndeda, Jared O. H.
    CLEAN ENERGY, 2025, 9 (02): : 161 - 176
  • [4] The Effect of Shielding Barriers on Solar Air Collector Gains
    Sikula, Ondrej
    Plasek, Josef
    Hirs, Jiri
    TERRAGREEN 13 INTERNATIONAL CONFERENCE 2013 - ADVANCEMENTS IN RENEWABLE ENERGY AND CLEAN ENVIRONMENT, 2013, 36 : 1070 - 1075
  • [5] Numerical Simulation and Experimental Study for Solar Air Collector with Hemispherical Protrusions on the Absorption Plate
    Li Shuilian
    Zeng F.
    Wei X.
    Applied Solar Energy, 2024, 60 (1) : 9 - 19
  • [6] Covered profiled steel cladding as an air heating solar collector: laboratory testing, modelling and validation
    Ho, KTK
    Loveday, DL
    ENERGY AND BUILDINGS, 1997, 26 (03) : 293 - 301
  • [7] Design and simulation of air-solar-finned reheating unit: An innovative design of a parabolic trough solar collector
    Nnamchi, S. N.
    Nnamchi, O. A.
    Onuorah, M. O.
    Nkurunziza, K. O.
    Ismael, S. A.
    COGENT ENGINEERING, 2020, 7 (01):
  • [8] Performance of a double pass solar air collector
    Ramani, B. M.
    Gupta, Akhilesh
    Kumar, Ravi
    SOLAR ENERGY, 2010, 84 (11) : 1929 - 1937
  • [9] Performance study of a novel solar air collector
    Peng, Donggen
    Zhang, Xiaosong
    Dong, Hua
    Lv, Kun
    APPLIED THERMAL ENGINEERING, 2010, 30 (16) : 2594 - 2601
  • [10] Numerical and experimental investigation of solar air collector with internal swirling flow
    Hu, Jianjun
    Guo, Meng
    Guo, Jinyong
    Zhang, Guangqiu
    Zhang, Yuwen
    RENEWABLE ENERGY, 2020, 162 (162) : 2259 - 2271