Con: The FloTrac Device Should Not Be Used to Follow Cardiac Output in Cardiac Surgical Patients

被引:4
|
作者
Singh, Saket [1 ]
Taylor, Mark A. [1 ]
机构
[1] Temple Univ, Western Penn Hosp, Dept Anesthesiol, Sch Med, Pittsburgh, PA 15224 USA
关键词
cardiac output; cardiac surgery; FloTrac; pulmonary artery catheterization; WAVE-FORM ANALYSIS; PULSE CONTOUR ANALYSIS; THERMODILUTION TECHNIQUE; MONITORING-SYSTEM; CATHETERIZATION; VALIDATION;
D O I
10.1053/j.jvca.2010.04.023
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页码:709 / 711
页数:3
相关论文
共 50 条
  • [1] Pro: The FloTrac Device Should Be Used to Follow Cardiac Output in Cardiac Surgical Patients
    Manecke, Gerard R., Jr.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (04) : 706 - 708
  • [2] Comparison of cardiac output measurements in critically ill patients: Flotrac/Vigileo vs transthoracic Doppler echocardiography
    McLean, A. S.
    Huang, S. J.
    Kot, M.
    Rajamani, A.
    Hoyling, L.
    ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (04) : 590 - 598
  • [3] Evaluation of a modified FloTrac™ algorithm for cardiac output measurement in cardiac surgery patients
    A Senn
    A Zollinger
    C Hofer
    Critical Care, 12 (Suppl 2):
  • [4] Continuous Arterial Pressure Waveform-Based Cardiac Output Using the FloTrac/Vigileo: A Review and Meta-analysis
    Mayer, Jochen
    Boldt, Joachim
    Poland, Reagan
    Peterson, Amanda
    Manecke, Gerard R.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 23 (03) : 401 - 406
  • [5] Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes
    Suehiro, K.
    Tanaka, K.
    Funao, T.
    Matsuura, T.
    Mori, T.
    Nishikawa, K.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (02) : 170 - 177
  • [6] Assessment of cardiac output changes using a modified FloTrac/Vigileo™ algorithm in cardiac surgery patients
    Senn, Alban
    Button, Danny
    Zollinger, Andreas
    Hofer, Christoph K.
    CRITICAL CARE, 2009, 13 (02):
  • [7] The accuracy of the Vigileo/FloTrac continuous cardiac output monitor
    Zimmermann, Andreas
    Kufner, Christine
    Hofbauer, Stephan
    Steinwendner, Joachim
    Hitzl, Wolfgang
    Fritsch, Gerhard
    Schistek, Roland
    Kirnbauer, Michael
    Pauser, Gernot
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (03) : 388 - 393
  • [8] Pulse contour cardiac output: an evaluation of the FloTrac method
    Ostergaard, Morten
    Nielsen, Jonas
    Nygaard, Eigil
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (06) : 484 - 489
  • [9] Con: Metabolic Acidosis Should Not Be Corrected With Sodium Bicarbonate in Cardiac Surgical Patients
    Jia, Shawn
    Kumar, Priya
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (02) : 619 - 621
  • [10] Con: Aprotinin should not be used in cardiac surgery with cardiopulmonary bypass
    Augoustides, John G. T.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (02) : 302 - 304