Energy spectra in water for the 6 MV X-ray therapeutic beam generated by Clinac-2300 linac

被引:29
|
作者
Konefal, Adam [1 ]
Bakoniak, Marzena [1 ]
Orlef, Andrzej [2 ]
Maniakowski, Zbigniew [2 ]
Szewczuk, Marek [2 ]
机构
[1] Silesian Univ, Inst Phys, Dept Nucl Phys & its Applicat, PL-40007 Katowice, Poland
[2] Ctr Oncol, Dept Med Phys, Gliwice Branch, PL-44100 Gliwice, Poland
关键词
Energy spectra in water; 6 MV therapeutic X-rays; MEASURED TRANSMISSION DATA; MONTE-CARLO CALCULATION; PHOTON-BEAM; BREMSSTRAHLUNG SPECTRA; DOSE CALCULATION; STOPPING-POWER; ELECTRON-BEAM; DOSIMETRY; RECONSTRUCTION; DISTRIBUTIONS;
D O I
10.1016/j.radmeas.2014.11.008
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
There is a lack of extensive data comprising energy spectra of therapeutic beams used in tele-radiotherapy, generated by medical linear accelerators. In particular there is a lack of the data for energy spectra in water. However, the spectra in water differ from those in air significantly because of strong photon scattering processes. The aim of this paper was the presentation of the wide range of detailed data for the 6 MV X-ray therapeutic beams from a medical linear accelerator Clinac-2300 by Varian. The presented data were derived by the use of Monte Carlo computer simulations (GEANT4 code). The performed investigations indicate that shapes of the spectra, total number of photon registered in a bin as well as mean energy of the considered beam depend on a depth in water, on a distance from the central-axis of the beam and on a radiation field size. However, shapes of the spectra as well as the beam mean energy does not depend on a bin size, independently of a depth in water and a radiation field whereas total number of photon registered in a bin is related to a bin size. Majority of the presented results were obtained for a cylindrical 1.41 cm(3) bin with the radius of 1.5 cm. The obtained data are very useful for the accurate absorbed depth-dose determination particularly outside the reference conditions, for advanced treatment planning systems, for constructors of medical accelerators etc. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:12 / 22
页数:11
相关论文
共 9 条
  • [1] Influence of the Radiation Field Size and the Depth in Irradiated Medium on Energy Spectra of the 6 MV X-Ray Beams from Medical Linac
    Konefal, Adam
    Orlef, Andrzej
    Maniakowski, Zbigniew
    SOME ASPECTS OF MEDICAL PHYSICS - IN VIVO AND IN VITRO STUDIES, 2010, 1 : 115 - 118
  • [2] DETERMINATION OF ENERGY SPECTRA IN WATER FOR 6 MV X RAYS FROM A MEDICAL LINAC
    Pietrzak, Robert
    Konefal, Adam
    ACTA PHYSICA POLONICA B, 2016, 47 (03): : 783 - 788
  • [3] The influence of a novel transmission detector on 6 MV x-ray beam characteristics
    Venkataraman, Sankar
    Malkoske, Kyle E.
    Jensen, Martin
    Nakonechny, Keith D.
    Asuni, Ganiyu
    McCurdy, Boyd M. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (10) : 3173 - 3183
  • [4] A Study On the Influence of Photonuclear Reactions On the Biological Effectiveness of Therapeutic High Energy X-Ray Beam
    Wakita, A.
    Matsufuji, N.
    Kohno, T.
    Kodaira, S.
    Yokoyama, K.
    Suzuki, Y.
    Itami, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 227 - 227
  • [5] Dose Rate Influence on Deep Dose Deposition Using a 6 MV X-Ray Beam From a Linear Accelerator
    Sousa, R. V.
    BRAZILIAN JOURNAL OF PHYSICS, 2009, 39 (02) : 292 - 296
  • [6] Technical note: Energy dependence of the new Gafchromic EBT4 film: Dose-response curves for 70 kV, 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV x-ray beams
    Chan, Maria F.
    Park, Jeonghoon
    Aydin, Resat
    Lim, Seng-Boh
    MEDICAL PHYSICS, 2023, 50 (06) : 3738 - 3745
  • [7] A STUDY OF THE SHIELDING USED TO REDUCE LEAKAGE AND SCATTERED RADIATION TO THE FETUS IN A PREGNANT PATIENT TREATED WITH A 6-MV EXTERNAL X-RAY BEAM
    Han, Bin
    Bednarz, Bryan
    Xu, X. George
    HEALTH PHYSICS, 2009, 97 (06): : 581 - 589
  • [8] Characterization of a new transmission detector for patient individualized online plan verification and its influence on 6MV X-ray beam characteristics
    Thoelking, Johannes
    Sekar, Yuvaraj
    Fleckenstein, Jens
    Lohr, Frank
    Wenz, Frederik
    Wertz, Hansjoerg
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (03): : 200 - 208
  • [9] Fiber-coupled organic plastic scintillator for on-line dose rate monitoring in 6 MV X-ray beam for external radiotherapy
    Lindvold, Lars R.
    Beierholm, A. R.
    Andersen, C. E.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS X, 2010, 7559