Differences in isometric neck muscle strength between healthy controls and women with chronic neck pain: The use of a reliable measurement

被引:83
作者
Cagnie, Barbara
Cools, Ann
De Loose, Veerle
Cambier, Dirk
Danneels, Lieven
机构
[1] Ghent Univ Hosp, Dept Rehabil Sci & Physiotherapy, B-9000 Ghent, Belgium
[2] Queen Astrid Mil Hosp, Ctr Phys Med & Rehabil, Dept Phys Therapy, Brussels, Belgium
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2007年 / 88卷 / 11期
关键词
neck pain; rehabilitation; reliability and; validity;
D O I
10.1016/j.apmr.2007.06.776
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Cagnie B, Cools A, De Loose V, Cambier D, Danneels L. Differences in isometric neck muscle strength between healthy controls and women with chronic neck pain: the use of a reliable measurement. Arch Phys Med Rehabil 2007;88:1441-5. Objectives: To determine the intra- and interrater reliability of the Biodex isokinetic dynamometer to measure the maximal isometric strength of the cervical flexors and extensors, to develop an age- and sex-based normative database in a healthy population, and to evaluate the differences in neck strength between women with chronic neck pain and healthy controls. Design: Cross-sectional. Setting: Physical and rehabilitation medicine department. Participants: Ninety-six healthy volunteers (4 age groups: 20-29, 30-39, 40-49, 50-59y; each consisting of 12 men and 12 women) and 30 women with chronic neck pain. Interventions: Not applicable. Main Outcome Measures: Peak isometric strength of the cervical muscles was tested for flexion and extension by using the Biodex isokinetic dynamometer. The intra- and interrater reliability of the protocol was evaluated in 12 volunteers. Results: The reliability for strength was high for both flexion and extension (intraclass correlation coefficient, .92-.96). The mean peak torque for flexion and extension was significantly higher in men (24Nm, 36.4Nm, respectively) compared with women (16.6Nm, 26.5Nm, respectively) (P<.001). Peak torque production for extension was significantly lower in the patient group (22.3Nm) compared with the healthy female control group (26.5Nm) (P=.003). No significant differences in flexion strength between patient and female control group were found. Conclusions: Results show a high degree of intra- and interrater reliability in measuring isometric neck muscle strength when using the Biodex isokinetic dynamometer. The use of normative data for neck strength when evaluating patients with neck disorders needs to take sex into account. The current study has shown that women with chronic neck pain have lower neck muscle strength in extension than the healthy female group.
引用
收藏
页码:1441 / 1445
页数:5
相关论文
共 24 条
  • [1] Neck flexor muscle strength, efficiency, and relaxation times in normal subjects and subjects with unilateral neck pain and headache
    Barton, PM
    Hayes, KC
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (07): : 680 - 687
  • [2] Individual and work related risk factors for neck pain among office workers: a cross sectional study
    Cagnie, B.
    Danneels, L.
    Van Tiggelen, D.
    De Loose, V.
    Cambier, D.
    [J]. EUROPEAN SPINE JOURNAL, 2007, 16 (05) : 679 - 686
  • [3] Evaluation of cervical range of motion and isometric neck muscle strength: reliability and validity
    Chiu, TTW
    Lo, SK
    [J]. CLINICAL REHABILITATION, 2002, 16 (08) : 851 - 858
  • [4] Maximal isometric muscle strength of the cervical spine in healthy volunteers
    Chiu, TTW
    Lam, TH
    Hedley, AJ
    [J]. CLINICAL REHABILITATION, 2002, 16 (07) : 772 - 779
  • [5] Normative database of isometric cervical strength in a healthy population
    Garcés, GL
    Medina, D
    Milutinovic, L
    Garavote, P
    Guerado, E
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (03) : 464 - 470
  • [6] Maximal isometric strength of the cervical musculature in 100 healthy volunteers
    Jordan, A
    Mehlsen, J
    Bülow, PM
    Ostergaard, K
    Danneskiold-Samsoe, B
    [J]. SPINE, 1999, 24 (13) : 1343 - 1348
  • [7] Assessment of published reliability studies for cervical spine range-of-motion measurement tools
    Jordan, K
    [J]. JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2000, 23 (03) : 180 - 195
  • [8] Cervical strength of young adults in sagittal, coronal, and intermediate planes
    Kumar, S
    Narayan, Y
    Amell, T
    [J]. CLINICAL BIOMECHANICS, 2001, 16 (05) : 380 - 388
  • [9] Peolsson A, 2001, Physiother Res Int, V6, P15, DOI 10.1002/pri.210
  • [10] Muscle force measured using "break" testing with a hand-held myometer in normal subjects aged 20 to 69 years
    Phillips, BA
    Lo, SK
    Mastaglia, FL
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2000, 81 (05): : 653 - 661