A Hybrid Method for Prediction of Ash Fouling on Heat Transfer Surfaces

被引:0
作者
Cui, Fangshu [1 ]
Qin, Sheng [1 ]
Zhang, Jing [1 ]
Li, Mengwei [2 ]
Shi, Yuanhao [2 ,3 ]
机构
[1] North Univ China, Sch Data Sci & Technol, Taiyuan 030051, Peoples R China
[2] North Univ China, Sch Elect & Control Engn, Taiyuan 030051, Peoples R China
[3] Shanghai Jiao Tong Univ, Dept Automat, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
coal-fired power plant boiler; ash fouling prediction; cleanliness factor; machine-learning technique; SOOT-BLOWING OPTIMIZATION; DEPOSITION; REGRESSION; STATE;
D O I
10.3390/en15134658
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Soot blowing optimization is a key, but challenging question in the health management of coal-fired power plant boiler. The monitoring and prediction of ash fouling for heat transfer surfaces is an important way to solve this problem. This study provides a hybrid data-driven model based on advanced machine-learning techniques for ash fouling prediction. First, the cleanliness factor is utilized to represent the level of ash fouling, which is the original data from the distributed control system. The wavelet threshold denoising algorithm is employed as the data preprocessing approach. Based on the empirical mode decomposition (EMD), the denoised cleanliness factor data is decoupled into a series of intrinsic mode functions (IMFs) and a residual component. Second, the support vector regression (SVR) model is used to fit the residual, and the Gaussian process regression (GPR) model is applied to estimate the IMFs. The cleanliness factor data of ash accumulation on the heat transfer surface of diverse devices are deployed to appraise the performance of the proposed SVR + GPR model in comparison with the sole SVR, sole GPR, SVR + EDM and GPR + EDM models. The illustrative results prove that the hybrid SVR + GPR model is superior to other models and can obtain satisfactory effects both in one-step- and the multistep-ahead cleanliness factor predictions.
引用
收藏
页数:15
相关论文
共 35 条
  • [31] Optimization of Boiler Soot Blowing Based on Hamilton-Jacobi-Bellman Equation
    Wen, Jie
    Shi, Yuanhao
    Pang, Xiaoqiong
    Jia, Jianfang
    Zeng, Jianchao
    [J]. IEEE ACCESS, 2019, 7 : 20850 - 20862
  • [32] Energy-Related CO2 Emission in China's Provincial Thermal Electricity Generation: Driving Factors and Possibilities for Abatement
    Yan, Qingyou
    Wang, Yaxian
    Balezentis, Tomas
    Sun, Yikai
    Streimikiene, Dalia
    [J]. ENERGIES, 2018, 11 (05)
  • [33] Mathematical modeling and experimental validation of ash deposition in a pulverized-coal boiler
    Zheng, Shu
    Zeng, Xiongwei
    Qi, Chaobo
    Zhou, Huaichun
    [J]. APPLIED THERMAL ENGINEERING, 2017, 110 : 720 - 729
  • [34] Energy conservation and emission reduction of China's electric power industry
    Zhou, Kaile
    Yang, Shanlin
    Shen, Chao
    Ding, Shuai
    Sun, Chaoping
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 45 : 10 - 19
  • [35] A review on fly ash from coal-fired power plants: chemical composition, regulations, and health evidence
    Zierold, Kristina M.
    Odoh, Chisom
    [J]. REVIEWS ON ENVIRONMENTAL HEALTH, 2020, 35 (04) : 401 - 418