Adaptive-Harmonic Compensation in Residential Distribution Grid by Roof-Top PV Systems

被引:29
|
作者
Bighash, Esmaeil Zangeneh [1 ]
Sadeghzadeh, Seyed Mohammad [1 ]
Ebrahimzadeh, Esmaeil [2 ]
Blaabjerg, Frede [2 ]
机构
[1] Shahed Univ, Fac Engn, Tehran 3319118651, Iran
[2] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Highly efficient and reliable inverter concept (HERIC); model predictive current controller (MPCC); sliding discrete Fourier transform (SDFT); SHUNT ACTIVE-FILTER; POWER DISTRIBUTION-SYSTEM; VOLTAGE DETECTION; REACTIVE POWER; GENERATION; INVERTER; IMPLEMENTATION; PERFORMANCE; MITIGATION;
D O I
10.1109/JESTPE.2018.2792303
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The single-phase nonlinear loads are going to increase in the future and power quality concerns in the residential distribution grid. Since most of nonlinear loads have a dispersed nature, compensating these phenomena may be complicated. On the other hand, the increased capacity of single-phase grid-connected roof-top PV inverters in residential distribution grid can be an opportunity to engage these systems in the power quality issues as custom power devices. By implementing a proper control for roof-top PV inverters, these systems may in addition to inject the fundamental current, additionally act like a virtual harmonic resistance, and dedicate their additional current capacity to compensate the harmonics of residential distribution grid. In this paper, each roof-top PV system is a grid-harmonic supervisor, where it continually measures the PCC voltage harmonics by the sliding discrete Fourier transform algorithm and then individually compensates the measured harmonics by the proposed adaptive-harmonic compensator. In the proposed approach, a current reference is separately determined for compensating each harmonic component. Then, a specific amount of additional current capacity will be dedicated for each component to compensate by using adaptive gain. Finally, the current reference is controlled by a model predictive current controller. It has been tested in a single-phase transformerless inverter (highly efficient and reliable inverter concept) with an LCL filter at the output. Also, the effectiveness of the control scheme has been verified by MATLAB Simulink and experimental tests.
引用
收藏
页码:2098 / 2108
页数:11
相关论文
共 50 条
  • [41] Expansion of the residential photovoltaic systems and its harmonic impact on the distribution grid
    Fekete, Kresimir
    Klaic, Zvonimir
    Majdandzic, Ljubomir
    RENEWABLE ENERGY, 2012, 43 : 140 - 148
  • [42] Roof-top Modeling of Building for Microcellular Systems Using Double Diffraction Coefficient
    Soni, Sanjay
    Bhattacharya, Amitabha
    2009 4TH INTERNATIONAL CONFERENCE ON COMPUTERS AND DEVICES FOR COMMUNICATION (CODEC 2009), 2009, : 394 - 397
  • [43] Optimal planning and modelling of the solar roof-top PV system with different incentive policy schemes for residential prosumers: a real-time case study
    Nishanthy, J.
    Raja, S. Charles
    Priya, D. Bharathy
    ELECTRICAL ENGINEERING, 2025, 107 (02) : 1617 - 1641
  • [44] Impact of Uneven Shading by Neighboring Buildings and Clouds on the Conventional and Hybrid Configurations of Roof-Top PV Arrays
    Satpathy, Priya Ranjan
    Babu, Thanikanti Sudhakar
    Shanmugam, Sathish Kumar
    Popavath, Lakshman Naik
    Alhelou, Hassan Haes
    IEEE ACCESS, 2021, 9 (09): : 139059 - 139073
  • [45] Performance Analysis of 81.6 kWp Roof-top Solar PV Installed on Canopy Structure at WRLDC, Mumbai
    Prajapati, Pramod Kumar
    Pandey, Vivek
    Ahmad, Absar
    Chitturi, Srinivas
    Patil, Sunil K.
    Usha, S.
    2022 22ND NATIONAL POWER SYSTEMS CONFERENCE, NPSC, 2022,
  • [46] Design And Installation Of Grid Connected Roof Top Solar Pv System
    Mishra, Satya Sundar
    2018 INTERNATIONAL CONFERENCE ON RECENT INNOVATIONS IN ELECTRICAL, ELECTRONICS & COMMUNICATION ENGINEERING (ICRIEECE 2018), 2018, : 49 - 51
  • [47] Statistically adjusted engineering (SAE) modeling of metered roof-top photovoltaic (PV) output: California evidence
    DeBenedictis, A.
    Hoff, T. E.
    Price, S.
    Woo, C. K.
    ENERGY, 2010, 35 (10) : 4178 - 4183
  • [48] Evaluating the effects of high penetrations of roof-top wind turbines on secondary distribution circuits
    Kritharas, Petros P.
    Ochoa, Luis F.
    Papastergiou, Konstantinos D.
    Harrison, Gareth P.
    2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, VOLS 1-3, 2006, : 1295 - +
  • [49] Customer-driven demand response model for facilitating roof-top PV and wind power integration
    Mahmoudi, Nadali
    Shafie-khah, Miadreza
    Saha, Tapan K.
    Catalao, Joao P. S.
    IET RENEWABLE POWER GENERATION, 2017, 11 (09) : 1200 - 1210
  • [50] Control strategy for improving voltage quality in residential power distribution network consisting of roof-top photovoltaic-wind hybrid systems, battery storage and electric vehicles
    Behravesh, Vahid
    Keypour, Reza
    Foroud, Asghar Akbari
    SOLAR ENERGY, 2019, 182 : 80 - 95