Isotope Dilution Mass Spectrometry - A Primary Method of Measurement and Its Role for RM Certification

被引:108
作者
Vogl, Jochen [1 ]
Pritzkow, Wolfgang [1 ]
机构
[1] BAM, Fed Inst Mat Res & Testing, D-12205 Berlin, Germany
来源
MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA | 2010年 / 25卷 / 03期
关键词
HIGH-ACCURACY METHOD; ICP-MS; PROTEIN-METABOLISM; ELEMENTAL SPECIATION; UNCERTAINTY BUDGET; GEOLOGICAL SAMPLES; RATIO MEASUREMENTS; NITROGEN ISOTOPES; TRACE ANALYSIS; POTABLE WATER;
D O I
10.1007/s12647-010-0017-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article describes the application of isotope dilution mass spectrometry (IDMS) to the field of reference material (RM) characterisation focusing on the approach, which is applied by the IDMS group at BAM. Emphasis is placed on IDMS measurements of highest analytical quality. Basic principles as well as the equation system are being recalled. Different calibration strategies, such as single, double or triple IDMS, are critically reviewed and the achievable uncertainties are discussed. Differences in the application of thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICPMS) are discussed as well as differences between different types of mass spectrometers such as single collector versus multi-collector or quadrupole versus magnetic sector instruments. Possible sources of errors and bias are mentioned and correction models introduced and applied within the past years are discussed. Several examples for RM characterisations in the field of elemental analysis are shown, each demonstrating excellent analytical quality. In general it can be stated that IDMS is the most important reference method for elemental analysis, offering highest accuracy and precision or smallest measurement uncertainties, when properly applied. Thus IDMS represents by far the best suited reference met hod for RM characterisation. Due to its universal applicability IDMS offers sufficient potential to follow future needs in analytical chemistry as well as in the RM sector.
引用
收藏
页码:135 / 164
页数:30
相关论文
共 113 条
  • [1] PROPAGATION OF UNCERTAINTIES IN ISOTOPE-DILUTION MASS-SPECTROMETRY USING PULSE COUNTING DETECTION
    ADRIAENS, AG
    KELLY, WR
    ADAMS, FC
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (05) : 660 - 663
  • [2] Spatial location of the space charge effect in individual ion clouds using monodisperse dried microparticulate injection with a twin quadrupole inductively coupled plasma mass spectrometer
    Allen, LA
    Leach, JJ
    Houk, RS
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (13) : 2384 - 2391
  • [3] Determination of mercury in potable water by ICP-MS using gold as a stabilising agent
    Allibone, J
    Fatemian, E
    Walker, PJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (02) : 235 - 239
  • [4] DETERMINATION OF FISSION-PRODUCTS AND ACTINIDES IN SPENT NUCLEAR-FUELS BY ISOTOPE-DILUTION ION CHROMATOGRAPHY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    ALONSO, JIG
    SENA, F
    ARBORE, P
    BETTI, M
    KOCH, L
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (05) : 381 - 393
  • [5] Determination of butyltin compounds in environmental samples by isotope-dilution GC-ICP-MS
    Alonso, JIG
    Encinar, JR
    Gonzalez, PR
    Sanz-Medel, A
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) : 432 - 440
  • [6] [Anonymous], 2008, International vocabulary of metrology-Basic and general concepts and associated terms (VIM), JCGM 2008
  • [7] [Anonymous], INT SYST UN SI
  • [8] *ASTM, D262205 ASTM
  • [9] A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes
    Belshaw, NS
    Freedman, PA
    O'Nions, RK
    Frank, M
    Guo, Y
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 : 51 - 58
  • [10] Berglund M., 2004, HDB STABLE ISOTOPE A, V1, P820