A state-of-the-art seismic source model for the United Arab Emirates

被引:22
作者
Sawires, Rashad [1 ,2 ]
Pelaez, Jose A. [3 ]
AlHamaydeh, Mohammad [4 ]
Henares, Jesus [5 ]
机构
[1] Assiut Univ, Fac Sci, Dept Geol, Assiut 71516, Egypt
[2] Natl Autonomous Univ Mexico UNAM, Inst Geophys, Morelia Campus, Morelia 58190, Michoacan, Mexico
[3] Univ Jaen, Dept Phys, Jaen 23071, Spain
[4] Amer Univ Sharjah, Civil Engn Dept, POB 26666, Sharjah, U Arab Emirates
[5] Int Univ La Rioja, Logrono 26006, Spain
关键词
Seismic source model; Zagros-Biltis Fold Thrust Belt; Makran subduction zone; Focal mechanism; Seismic hazard; United Arab Emirates; SANANDAJ-SIRJAN ZONE; MAKRAN TRANSFER ZONE; FOCAL MECHANISM; STRIKE-SLIP; HAZARD ASSESSMENT; ZAGROS MOUNTAINS; FAULT SYSTEM; EURASIA CONVERGENCE; ACTIVE DEFORMATION; STRESS PATTERN;
D O I
10.1016/j.jseaes.2019.104063
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Despite the United Arab Emirates (UAE) is characterized by low to moderate local seismicity, the country is within close proximity to be affected by the surrounding seismically-active regions, mainly, the Zagros and the Makran regions. Appreciable ground shaking levels were felt in many parts of UAE during the past 15 years. A new seismic source model for UAE was specifically developed herein, as a first and significant step towards a critical re-evaluation of the seismic hazard in the UAE. Updated earthquake and focal mechanism catalogs have been incorporated in the definition and characterization of the seismic sources. This was done after unifying magnitudes, seismicity declustering, as well as performing completeness checks. Geological, tectonic, active faults, and crustal thickness information were considered in the delimitation of the source's boundaries. The proposed seismic source model consists of a total of 12 area seismic sources, i.e., 10 shallow-depth (h <= 35 km) and 2 intermediate-depth zones (35 < h <= 70 km) spanning the potential seismic regions which may contribute to the UAE seismic hazard. This work is the first in which intermediate-depth seismicity is included in a zoning model for the region. Separate earthquake and focal mechanism sub-catalogs were generated after the delimitation of each defined seismic source. The seismicity occurrence parameters (b-value, annual rate of earthquakes above Mw 4.0, and the maximum possible magnitude) were computed individually for each source. A predominant stress regime was also assigned to each seismic source based on the inversion of the available focal-mechanism data.
引用
收藏
页数:21
相关论文
共 140 条
  • [1] Seismic hazard assessment of United Arab emirates and its surroundings
    Abdalla, JA
    Al-Homoud, AS
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2004, 8 (06) : 817 - 837
  • [2] Crustal structure of Northwest Zagros (Kermanshah) and Central Iran (Yazd and Isfahan) using teleseismic Ps converted phases
    Afsari, Narges
    Sodoudi, Forogh
    Farahmand, Fataneh Taghizadeh
    Ghassemi, Mohammad Reza
    [J]. JOURNAL OF SEISMOLOGY, 2011, 15 (02) : 341 - 353
  • [3] Al Satari MH, 2005, Estimation of seismic response demands for RC framed structures
  • [4] Al-Haddad M., 1994, Earthq. Spectra, V10, P231, DOI [10.1193/1.1585773, DOI 10.1193/1.1585773]
  • [5] Probabilistic seismic hazard analysis for rock sites in the cities of Abu Dhabi, Dubai and Ra's Al Khaymah, United Arab Emirates
    Aldama-Bustos, G.
    Bommer, J. J.
    Fenton, C. H.
    Stafford, P. J.
    [J]. GEORISK-ASSESSMENT AND MANAGEMENT OF RISK FOR ENGINEERED SYSTEMS AND GEOHAZARDS, 2009, 3 (01) : 1 - 29
  • [6] AlHamaydeh M., 2012, INT J CIV ENV ENG, V6, P185
  • [7] Impact of Seismicity on Performance and Cost of RC Shear Wall Buildings in Dubai, United Arab Emirates
    AlHamaydeh, Mohammad
    Aly, Nader
    Galal, Khaled
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2017, 31 (05)
  • [8] Impact of lateral force-resisting system and design/construction practices on seismic performance and cost of tall buildings in Dubai, UAE
    AlHamaydeh, Mohammad
    Galal, Khaled
    Yehia, Sherif
    [J]. EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2013, 12 (03) : 385 - 397
  • [9] Seismic design factors for RC special moment resisting frames in Dubai, UAE
    AlHamaydeh, Mohammad
    Abdullah, Sulayman
    Hamid, Ahmed
    Mustapha, Abdilwahhab
    [J]. EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2011, 10 (04) : 495 - 506
  • [10] Optimized frequency-based foundation design for wind turbine towers utilizing soil-structure interaction
    AlHamaydeh, Mohammad
    Hussain, Saif
    [J]. JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2011, 348 (07): : 1470 - 1487