Containment versus impingement: finding a compromise for cup placement in total hip arthroplasty

被引:69
作者
Widmer, K.-H. [1 ]
机构
[1] Kantonsspital Schaffhausen, Dept Orthoped Surg & Traumatol, CH-8208 Schaffhausen, Switzerland
关键词
D O I
10.1007/s00264-007-0429-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recommendations for cup containment and impingement may provide conflicting directions for component orientation in total hip arthroplasty. For optimal containment, the cup is positioned with respect to the acetabular bone, resulting in coincidence of the rim of the cup and the acetabulum. This results in good coverage and symmetric load transfer, leading to good long-term stability, but occasionally necessitates more abduction of the cup than that recommended by the safe zone. On the other hand, placement of the cup for an optimal range of motion would lead to only partial containment, with a higher risk of component loosening and revision. The most effective compromise is to use a prosthesis that has a large safe zone, realised by a high head-to-neck ratio, and orienting the cup such that a good containment is achieved and the safe zone is respected. Computer navigation or smart aiming devices may help to find the best relative orientation.
引用
收藏
页码:S29 / S33
页数:5
相关论文
共 15 条
[1]  
ELKE R, 1992, ORTHOPADE, V21, P51
[2]  
Laursen JO, 1998, ORTHOPEDICS, V21, P277
[3]   DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220
[4]   The anatomic basis for the concept of lateralized femoral stems - A frontal plane radiographic study of the proximal femur [J].
Massin, P ;
Geais, L ;
Astoin, E ;
Simondi, M ;
Lavaste, F .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :93-101
[5]  
MORSCHER EW, 1992, CLIN ORTHOP RELAT R, P172
[6]  
NOBLE PC, 1988, CLIN ORTHOP RELAT R, P148
[7]  
Ranawac CS., 1991, TECH ORTHOP, V6, P17, DOI [10.1097/00013611-199109000-00004, DOI 10.1054/ARTH.2001.24442, DOI 10.1097/00013611-199109000-00004]
[8]   CUP CONTAINMENT AND ORIENTATION IN CEMENTED TOTAL HIP ARTHROPLASTIES [J].
SARMIENTO, A ;
EBRAMZADEH, E ;
GOGAN, WJ ;
MCKELLOP, HA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06) :996-1002
[9]   Change of CCD angle and femoral anteversion angle by total hip replacement [J].
Schidlo, C ;
Becker, C ;
Jansson, V ;
Refior, J .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1999, 137 (03) :259-264
[10]   EXPERIMENTAL-DETERMINATION OF FRICTION CHARACTERISTICS AT THE TRABECULAR BONE POROUS-COATED METAL INTERFACE IN CEMENTLESS IMPLANTS [J].
SHIRAZIADL, A ;
DAMMAK, M ;
PAIEMENT, G .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (02) :167-175