Measurement of myocardial blood flow with oxygen-15 labelled water: comparison of different administration protocols

被引:94
作者
Hermansen, F
Rosen, SD
Fath-Ordoubadi, F
Kooner, JS
Clark, JC
Camici, PG
Lammertsma, AA
机构
[1] Hammersmith Hosp, Imperial Coll Sch Med, MRC, Cyclotron Unit,PET Methodol Grp, London, England
[2] Hammersmith Hosp, Imperial Coll Sch Med, MRC, Cyclotron Unit,PET Cardiol Grp, London, England
[3] Hammersmith Hosp, Imperial Coll Sch Med, Dept Cardiol, London, England
关键词
positron emission tomography; myocardial blood flow; oxygen-15 labelled water; tracer kinetic modelling;
D O I
10.1007/s002590050279
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron emission tomography (PET) in conjunction with (CO2)-O-15 or (H2O)-O-15 can be used to measure myocardial blood flow (MBF) and tissue fraction (TF), i.e, the fraction of the tissue mass in the volume of the region of interest. However, with (CO2)-O-15 inhalation, the tissue fraction in the septum is overestimated. Bolus injection of (H2O)-O-15 together with arterial cannulation gives very precise results but is invasive. The purpose of this study was to develop a method which circumvents these problems. A four-parameter model with parameters for MBF, TF and spill-over fractions from both left and right ventricular cavities was developed. This method was compared with a three-parameter model (no right ventricular cavity spill-over) in both septal and non-septal regions of interest for three different administration protocols: bolus injection of (H2O)-O-15, infusion of (H2O)-O-15 and inhalation of (CO2)-O-15. It was found that MBF can be measured with intravenous administration of (H2O)-O-15 without the requirement for arterial cannulation. The four-parameter protocol with bolus injection was stable in clinical studies. The four-parameter model proved essential for the septum, where it gave highly significantly better fits than did the three-parameter model (P<0.00003 in each of 15 subjects). Administration of (H2O)-O-15 together with this four-parameter model also circumvented the problem of overestimation of TF in the septum seen with (CO2)-O-15 inhalation. In addition, the radiation dose of (H2O)-O-15 protocols is lower than that of (CO2)-O-15 inhalation. Using a left atrial input curve instead of a left ventricular cavity input curve gave the same mean MBF and TF.
引用
收藏
页码:751 / 759
页数:9
相关论文
共 36 条
  • [1] [Anonymous], 1960, METHODS MED RES
  • [2] NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW IN CORONARY-ARTERY DISEASE WITH OXYGEN-15-LABELED CARBON-DIOXIDE INHALATION AND POSITRON EMISSION TOMOGRAPHY
    ARAUJO, LI
    LAMMERTSMA, AA
    RHODES, CG
    MCFALLS, EO
    IIDA, H
    RECHAVIA, E
    GALASSI, A
    DESILVA, R
    JONES, T
    MASERI, A
    [J]. CIRCULATION, 1991, 83 (03) : 875 - 885
  • [3] NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY
    BERGMANN, SR
    HERRERO, P
    MARKHAM, J
    WEINHEIMER, CJ
    WALSH, MN
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) : 639 - 652
  • [4] QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW INVIVO WITH (H2O)-O-15
    BERGMANN, SR
    FOX, KAA
    RAND, AL
    MCELVANY, KD
    WELCH, MJ
    MARKHAM, J
    SOBEL, BE
    [J]. CIRCULATION, 1984, 70 (04) : 724 - 733
  • [5] BONOW RO, 1989, J NUCL MED, V30, P420
  • [6] PREOPERATIVE PREDICTION OF THE OUTCOME OF CORONARY REVASCULARIZATION USING POSITRON EMISSION TOMOGRAPHY
    DESILVA, R
    YAMAMOTO, Y
    RHODES, CG
    IIDA, H
    NIHOYANNOPOULOS, P
    DAVIES, GJ
    LAMMERTSMA, AA
    JONES, T
    MASERI, A
    [J]. CIRCULATION, 1992, 86 (06) : 1738 - 1742
  • [7] Calculation of single detector efficiencies and extension of the normalization sinogram in PET
    Hermansen, F
    Spinks, TJ
    Camici, PG
    Lammertsma, AA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06) : 1143 - 1154
  • [8] HERMANSEN F, 1996, EUR J NUCL MED, V23, P1235
  • [9] HERRERO P, 1995, J NUCL MED, V36, P320
  • [10] QUANTITATION OF MYOCARDIAL BLOOD-FLOW WITH (H2O)-O-15 AND POSITRON EMISSION TOMOGRAPHY - ASSESSMENT AND ERROR ANALYSIS OF A MATHEMATICAL APPROACH
    HERRERO, P
    MARKHAM, J
    BERGMANN, SR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (05) : 862 - 873