Validation of fast Monte Carlo dose calculation in small animal radiotherapy with EBT3 radiochromic films

被引:14
作者
Noblet, C. [1 ]
Chiavassa, S. [1 ,2 ]
Smekens, F. [3 ]
Sarrut, D. [3 ]
Passal, V. [2 ]
Suhard, J. [1 ]
Lisbona, A. [1 ,2 ]
Paris, F. [1 ]
Delpon, G. [1 ,2 ]
机构
[1] IRT UN, INSERM UMR 892, 8 Quai Moncousu, F-44007 Nantes, France
[2] Ctr Rene Gauducheau, Inst Cancerol Ouest, F-44805 St Herblain, France
[3] Univ Lyon 1, Ctr Leon Berard, INSA Lyon, CREATIS,CNRS,UMR5220,Inserm,U1044, F-69622 Villeurbanne, France
关键词
Monte Carlo simulation; dosimetry; small animal radiotherapy; seTLE; LNE-LNHB; PHOTON; BEAM; DOSIMETRY; SYSTEM; WATER; ELECTRON; GATE;
D O I
10.1088/0031-9155/61/9/3521
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In preclinical studies, the absorbed dose calculation accuracy in small animals is fundamental to reliably investigate and understand observed biological effects. This work investigated the use of the split exponential track length estimator (seTLE), a new kerma based Monte Carlo dose calculation method for preclinical radiotherapy using a small animal precision micro irradiator, the X-RAD 225Cx. Monte Carlo modelling of the irradiator with GATE/GEANT4 was extensively evaluated by comparing measurements and simulations for half-value layer, percent depth dose, off-axis profiles and output factors in water and water-equivalent material for seven circular fields, from 20 mm down to 1 mm in diameter. Simulated and measured dose distributions in cylinders of water obtained for a 360 degrees arc were also compared using dose, distance-to-agreement and gamma-index maps. Simulations and measurements agreed within 3% for all static beam configurations, with uncertainties estimated to 1% for the simulation and 3% for the measurements. Distance-to-agreement accuracy was better to 0.14 mm. For the arc irradiations, gamma-index maps of 2D dose distributions showed that the success rate was higher than 98%, except for the 0.1 cm collimator (92%). Using the seTLE method, MC simulations compute 3D dose distributions within minutes for realistic beam configurations with a clinically acceptable accuracy for beam diameter as small as 1 mm.
引用
收藏
页码:3521 / +
页数:15
相关论文
共 30 条
  • [1] Andreo PBD., 2000, TECHNICAL REPORT SER, V18, P35
  • [2] Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies
    Arjomandy, Bijan
    Tailor, Ramesh
    Anand, Aman
    Sahoo, Narayan
    Gillin, Michael
    Prado, Karl
    Vicic, Milos
    [J]. MEDICAL PHYSICS, 2010, 37 (05) : 1942 - 1947
  • [3] The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy
    Bazalova, Magdalena
    Graves, Edward E.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3039 - 3049
  • [4] Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification
    Borca, Valeria Casanova
    Pasquino, Massimo
    Russo, Giuliana
    Grosso, Pierangelo
    Cante, Domenico
    Sciacero, Piera
    Girelli, Giuseppe
    La Porta, Maria Rosa
    Tofani, Santi
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02): : 158 - 171
  • [5] CHIAVASSA S, 2013, PHYS MEDICA, V29, pE9, DOI DOI 10.1016/j.ejmp.2013.08.033
  • [6] Characterization of image quality and image-guidance performance of a preclinical microirradiator
    Clarkson, R.
    Lindsay, P. E.
    Ansell, S.
    Wilson, G.
    Jelveh, S.
    Hill, R. P.
    Jaffray, D. A.
    [J]. MEDICAL PHYSICS, 2011, 38 (02) : 845 - 856
  • [7] On the use of an analytic source model for dose calculations in precision image-guided small animal radiotherapy
    Granton, Patrick V.
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (10) : 3377 - 3395
  • [8] A combined dose calculation and verification method for a small animal precision irradiator based on onboard imaging
    Granton, Patrick V.
    Podesta, Mark
    Landry, Guillaume
    Nijsten, Sebastiaan
    Bootsma, Gregory
    Verhaegen, Frank
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4155 - 4166
  • [9] Advances in kilovoltage x-ray beam dosimetry
    Hill, Robin
    Healy, Brendan
    Holloway, Lois
    Kuncic, Zdenka
    Thwaites, David
    Baldock, Clive
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (06) : R183 - R231
  • [10] GATE:: a simulation toolkit for PET and SPECT
    Jan, S
    Santin, G
    Strul, D
    Staelens, S
    Assié, K
    Autret, D
    Avner, S
    Barbier, R
    Bardiès, M
    Bloomfield, PM
    Brasse, D
    Breton, V
    Bruyndonckx, P
    Buvat, I
    Chatziioannou, AF
    Choi, Y
    Chung, YH
    Comtat, C
    Donnarieix, D
    Ferrer, L
    Glick, SJ
    Groiselle, CJ
    Guez, D
    Honore, PF
    Kerhoas-Cavata, S
    Kirov, AS
    Kohli, V
    Koole, M
    Krieguer, M
    van der Laan, DJ
    Lamare, F
    Largeron, G
    Lartizien, C
    Lazaro, D
    Maas, MC
    Maigne, L
    Mayet, F
    Melot, F
    Merheb, C
    Pennacchio, E
    Perez, J
    Pietrzyk, U
    Rannou, FR
    Rey, M
    Schaart, DR
    Schmidtlein, CR
    Simon, L
    Song, TY
    Vieira, JM
    Visvikis, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19) : 4543 - 4561