Impact of blood pressure on the Doppler echocardiographic assessment of severity of aortic stenosis

被引:77
作者
Little, Stephen H. [1 ]
Chan, Kwan-Leung [1 ]
Burwash, Ian G. [1 ]
机构
[1] Univ Ottawa, Inst Heart, Dept Med, Div Cardiol, Ottawa, ON K1Y 4W7, Canada
关键词
STROKE WORK LOSS; EQUATION VALVE AREAS; CONTINUITY EQUATION; ORIFICE AREA; FLOW-RATE; GORLIN FORMULA; SYSTEMIC HYPERTENSION; VOLUME FLOW; IN-VITRO; RESISTANCE;
D O I
10.1136/hrt.2006.098392
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To investigate the impact of blood pressure (BP) on the Doppler echocardiographic (Doppler-echo) evaluation of severity of aortic stenosis (AS). Methods: Handgrip exercise or phenylephrine infusion was used to increase BP in 22 patients with AS. Indices of AS severity (mean pressure gradient (Delta P-mean), aortic valve area (AVA), valve resistance, percentage left ventricular stroke work loss (% LVSW loss) and the energy loss coefficient (ELCo)) were measured at baseline, peak BP intervention and recovery. Results: From baseline to peak intervention, mean (SD) BP increased (99 (8) vs 121 (10) mm Hg, p<0.001), systemic vascular resistance (SVR) increased (1294 (264) vs 1552 (372) dynexs/cm(5), p<0.001) and mean (SD) transvalvular flow rate (Q(mean)) decreased (323 (67) vs 306 (66) ml/s, p = 0.02). There was no change in DPmean (36 (13) vs 36 (14) mm Hg, p = NS). However, there was a decrease in AVA (1.15 (0.32) vs 1.09 (0.33) cm(2), p = 0.02) and ELCo (1.32 (0.40) vs 1.24 (0.42) cm2, p = 0.04), and an increase in valve resistance (153 (63) vs 164 (74) dynexs/cm(5), p = 0.02), suggesting a more severe valve stenosis. In contrast, % LVSW loss decreased (19.8 (6) vs 16.5 (6)%, p<0.001), suggesting a less severe valve stenosis. There was an inverse relationship between the change in mean BP and AVA (r = -0.34, p = 0.02); however, only the change in Qmean was an independent predictor of the change in AVA (r = 0.81, p<0.001). Conclusions: Acute BP elevation due to increased SVR can affect the Doppler-echo evaluation of AS severity. However, the impact of BP on the assessment of AS severity depends primarily on the associated change in Q(mean), rather than on an independent effect of SVR or arterial compliance, and can result in a valve appearing either more or less stenotic depending on the direction and magnitude of the change in Q(mean).
引用
收藏
页码:848 / 855
页数:8
相关论文
共 46 条
[11]   DEPENDENCE OF GORLIN FORMULA AND CONTINUITY EQUATION VALVE AREAS ON TRANSVALVULAR VOLUME FLOW-RATE IN VALVULAR AORTIC-STENOSIS [J].
BURWASH, IG ;
THOMAS, DD ;
SADAHIRO, M ;
PEARLMAN, AS ;
VERRIER, ED ;
THOMAS, R ;
KRAFT, CD ;
OTTO, CM .
CIRCULATION, 1994, 89 (02) :827-835
[12]   ECHOCARDIOGRAPHIC VOLUME FLOW AND STENOSIS SEVERITY MEASURES WITH CHANGING FLOW-RATE IN AORTIC-STENOSIS [J].
BURWASH, IG ;
FORBES, AD ;
SADAHIRO, M ;
VERRIER, ED ;
PEARLMAN, AS ;
THOMAS, R ;
KRAFT, C ;
OTTO, CM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (05) :H1734-H1743
[13]   EFFECTS OF DOBUTAMINE ON GORLIN AND CONTINUITY EQUATION VALVE AREAS AND VALVE RESISTANCE IN VALVULAR AORTIC-STENOSIS [J].
CASALE, PN ;
PALACIOS, IF ;
ABASCAL, VM ;
HARRELL, L ;
DAVIDOFF, R ;
WEYMAN, AE ;
FIFER, MA .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (13) :1175-1179
[14]  
CHAMBERS J, 1998, J HEART VALVE DIS, V7, P277
[15]  
CHAMBERS JB, 1992, BRIT HEART J, V67, P193
[16]   Case-controlled study to assess risk factors for aortic stenosis in congenitally bicuspid aortic valve [J].
Chan, KL ;
Ghani, M ;
Woodend, K ;
Burwash, IG .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (06) :690-693
[17]   Total arterial compliance estimated by stroke volume to aortic pulse pressure ratio in humans [J].
Chemla, D ;
Hébert, JL ;
Coirault, C ;
Zamani, K ;
Suard, I ;
Colin, P ;
Lecarpentier, Y .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (02) :H500-H505
[18]   The patient with a systolic murmur: severe aortic stenosis may be missed during cardiovascular examination [J].
Das, P ;
Pocock, C ;
Chambers, J .
QJM-MONTHLY JOURNAL OF THE ASSOCIATION OF PHYSICIANS, 2000, 93 (10) :685-688
[19]   Analysis of the effect of flow rate on the Doppler continuity equation for stenotic orifice area calculations - A numerical study [J].
DeGroff, CG ;
Shandas, R ;
Valdes-Cruz, L .
CIRCULATION, 1998, 97 (16) :1597-1605
[20]   VALVE RESISTANCE [J].
FORD, LE ;
FELDMAN, T ;
CARROLL, JD .
CIRCULATION, 1994, 89 (02) :893-895