Serial Doppler echocardiographic evaluation of small-sized Sorin Bicarbon prostheses

被引:13
作者
De Carlo, M [1 ]
Milano, AD [1 ]
Nardi, C [1 ]
Mecozzi, G [1 ]
Bortolotti, U [1 ]
机构
[1] Univ Pisa, Sch Med, Cardiothorac Dept, I-56100 Pisa, Italy
关键词
D O I
10.1016/S0022-5223(02)73395-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The Sorin Bicarbon prosthesis (Sorin Biomedica, Saluggia, Italy) is a bileaflet valve with curved-profile leaflets, a rolling hinge mechanism, and a pyrolytic carbon-coated titanium alloy housing and sewing ring. Although the Sorin Bicarbon prosthesis has been implanted in greater than 80,000 patients, and reference values on the hemodynamic performance of valve prostheses are needed to avoid patient-prosthesis mismatch, few Doppler echocardiographic data are available on the prosthesis in the aortic position. The aim of this study is to provide a detailed echocardiographic evaluation of the hemodynamic performance and regression of left ventricular hypertrophy after aortic valve replacement with the Sorin Bicarbon prosthesis. Methods: The study included 182 patients who received a 21-mm (n = 61) or 23-mm (n = 121) Sorin Bicarbon prosthesis for pure or prevalent aortic stenosis who underwent serial echocardiograms at 3, 6, and 12 months after aortic. valve replacement. Results: Mean and peak gradients significantly decreased (P < .001) during follow-up to values of 12 +/- 3 and 22 +/- 6 mm Hg for the 21-mm prosthesis and values of 11 +/- 4 and 19 +/- 6 mm Hg for the 23-mm prosthesis at I year. Left ventricular mass index showed a 17% decrease to 120 +/- 27 g/m(2) in recipients of the 21-mm prosthesis (P < .001),and a 21% decrease to 123 +/- 29 g/m(2) in recipients of the 23-mm prosthesis (P < .001). A larger prosthesis size was the only predictor of a higher left ventricular mass index regression. Among recipients of the 21-mm prosthesis, body surface area of greater than 1.85 m(2) was,associated with a lower regression of left ventricular mass index. The effective orifice area index was 1.00 +/- 0.11 and 1.08 +/- 0.14 cm(2)/m(2) in recipients of the 21-mm and 23-mm prostheses, respectively. Conclusions: Size 21 mm and 23 mm Sorin Bicarbon prostheses show low transprosthetic gradients, with significant reduction of left ventricular mass index during the first postoperative year. The reported effective orifice areas might be useful for aortic valve replacement in patients with a small aortic annulus to avoid patient-prosthesis mismatch.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 27 条
  • [11] Flameng W, 1997, J HEART VALVE DIS, V6, P269
  • [12] Evaluation of the Sorin bicarbon bileaflet valve in 488 patients (519 prostheses)
    Goldsmith, I
    Lip, GYH
    Patel, RL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (07) : 1069 - 1074
  • [13] Influence of the size of aortic valve prostheses on hemodynamics and change in left ventricular mass: Implications for the surgical management of aortic stenosis
    GonzalezJuanatey, JR
    GarciaAcuna, JM
    Fernandez, MV
    Cendon, AA
    Fuentes, VC
    GarciaBengoechea, JB
    delaPena, MG
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (02) : 273 - 280
  • [14] Hemodynamic performance of small-size bileaflet valves: Pressure drop and laser Doppler anemometry study comparison of three prostheses
    Grigioni, M
    Daniele, C
    D'Avenio, G
    Barbaro, V
    [J]. ARTIFICIAL ORGANS, 2000, 24 (12) : 959 - 965
  • [15] Hemodynamic performance of the 21-mm Sorin Bicarbon mechanical aortic prostheses using dobutamine Doppler echocardiography
    Kadir, I
    Wan, IYP
    Walsh, C
    Wilde, P
    Bryan, AJ
    Angelini, GD
    [J]. ANNALS OF THORACIC SURGERY, 2001, 72 (01) : 49 - 53
  • [16] Karpuz H, 1996, Am J Card Imaging, V10, P254
  • [17] Assessment of small-diameter aortic mechanical prostheses - Physiological relevance of the Doppler gradient, utility of flow augmentation, and limitations of orifice area estimation
    Marcus, RH
    Heinrich, RS
    Bednarz, J
    Lupovitch, S
    Abruzzo, J
    Borok, R
    Vandenberg, B
    Kerber, RE
    Piccione, W
    Yoganathan, AP
    Lang, RM
    [J]. CIRCULATION, 1998, 98 (09) : 866 - 872
  • [18] Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
    Pibarot, P
    Dumesnil, JG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) : 1131 - 1141
  • [19] PROBLEM OF VALVE PROSTHESIS PATIENT MISMATCH
    RAHIMTOOLA, SH
    [J]. CIRCULATION, 1978, 58 (01) : 20 - 24
  • [20] REUL H, 1993, J THORAC CARDIOV SUR, V106, P412