Measurement of the 3D arterial wall strain tensor using intravascular B-mode ultrasound images: a feasibility study

被引:8
作者
Liang, Yun [1 ]
Zhu, Hui [1 ]
Friedman, Morton H. [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
CORONARY-ARTERIES; IN-VIVO; ELASTOGRAPHY; REDUCTION;
D O I
10.1088/0031-9155/55/21/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intravascular ultrasound (IVUS) elastography is a promising tool for studying atherosclerotic plaque composition and assessing plaque vulnerability. Current IVUS elastography techniques can measure the 1D or 2D strain of the vessel wall using various motion tracking algorithms. Since biological soft tissue tends to deform non-uniformly in 3D, measurement of the complete 3D strain tensor is desirable for more rigorous analysis of arterial wall mechanics. In this paper, we extend our previously developed method of 2D arterial wall strain measurement based on non-rigid image registration into 3D strain measurement. The new technique registers two image volumes acquired from the same vessel segment under different levels of luminal pressure and longitudinal stress. The 3D displacement field obtained from the image registration is used to calculate the local 3D strain tensor. From the 3D strain tensor, radial, circumferential and longitudinal strain distributions can be obtained and displayed. This strain tensor measurement method is validated and evaluated using IVUS images of healthy porcine carotid arteries subjected to a luminal pressure increase and longitudinal stretch. The ability of the algorithm to overcome systematic noise was tested, as well as the consistency of the results under different longitudinal frame resolutions.
引用
收藏
页码:6377 / 6394
页数:18
相关论文
共 13 条
[1]  
[Anonymous], 2002, CARDIOVASCULAR SOLID, DOI DOI 10.1007/978-0-387-21576-1
[2]   Axial movement of the intravascular ultrasound probe during the cardiac cycle: Implications for three-dimensional reconstruction and measurements of coronary dimensions [J].
Arbab-Zadeh, A ;
DeMaria, AN ;
Penny, WF ;
Russo, RJ ;
Kimura, BJ ;
Bhargava, V .
AMERICAN HEART JOURNAL, 1999, 138 (05) :865-872
[3]   Morphological and mechanical information of coronary arteries obtained with intravascular elastography - Feasibility study in vivo [J].
de Korte, CL ;
Carlier, SG ;
Mastik, F ;
Doyley, MM ;
van der Steen, AFW ;
Serruys, PW ;
Bom, N .
EUROPEAN HEART JOURNAL, 2002, 23 (05) :405-413
[4]   Pathogenesis of atherosclerosis [J].
Falk, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (08) :C7-C12
[5]   Angle matching in intravascular elastography [J].
Janssen, CRM ;
de Korte, CL ;
van der Heiden, MS ;
Wapenaar, CP ;
van der Steen, AFW .
ULTRASONICS, 2000, 38 (1-8) :417-423
[6]  
LEER T, 1991, CIRCULATION, V83, P1764
[7]  
LEUNG KYE, CONTROL */* FERROELE, V53, P1269
[8]  
SAIJO Y, 2005, VASCULAR ULTRASOUND
[9]   Systolic axial artery length reduction: an overlooked phenomenon in vivo [J].
Tozzi, P ;
Hayoz, D ;
Oedman, C ;
Mallabiabarrena, I ;
Von Segesser, LK .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 280 (05) :H2300-H2305
[10]   Noise reduction in elastograms using temporal stretching with multicompression averaging [J].
Varghese, T ;
Ophir, J ;
Cespedes, I .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (08) :1043-1052