2D measurements of cup orientation are less reliable than 3D measurements

被引:0
作者
Davda, Kinner [1 ]
Smyth, Niall [2 ]
Cobb, Justin P. [1 ]
Hart, Alister J. [3 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Charing Cross Hosp, London, England
[2] Hosp Special Serv, New York, NY USA
[3] Royal Natl Orthopaed Hosp, Stanmore HA7 4LP, Middx, England
关键词
ACETABULAR COMPONENT POSITION; TOTAL HIP-REPLACEMENT; NAVIGATION; VERSION; TILT;
D O I
10.3109/17453674.2016.1156932
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
[No abstract available]
引用
收藏
页码:314 / 317
页数:4
相关论文
共 18 条
  • [1] The rationale for tilt-adjusted acetabular cup navigation
    Babisch, Juergen W.
    Layher, Frank
    Amiot, Louis-Philippe
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (02) : 357 - 365
  • [2] 2D measurements of cup orientation are less reliable than 3D measurements A retrospective study of 87 metal-on-metal hips
    Davda, Kinner
    Smyth, Niall
    Cobb, Justin P.
    Hart, Alister J.
    [J]. ACTA ORTHOPAEDICA, 2015, 86 (04) : 485 - 490
  • [3] A New Technique for Radiographic Measurement of Acetabular Cup Orientation
    Derbyshire, Brian
    Diggle, Peter J.
    Ingham, Christopher J.
    Macnair, Rory
    Wimhurst, James
    Jones, Henry Wynn
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (02) : 369 - 372
  • [4] Correction of acetabular cup orientation measurements for X-ray beam offset
    Derbyshire, Brian
    [J]. MEDICAL ENGINEERING & PHYSICS, 2008, 30 (09) : 1119 - 1126
  • [5] Functional acetabular component position with supine total hip replacement
    Eilander, W.
    Harris, S. J.
    Henkus, H. E.
    Cobb, J. P.
    Hogervorst, T.
    [J]. BONE & JOINT JOURNAL, 2013, 95B (10) : 1326 - 1331
  • [6] Optimal acetabular orientation for hip resurfacing
    Grammatopoulos, G.
    Pandit, H.
    Glyn-Jones, S.
    McLardy-Smith, P.
    Gundle, R.
    Whitwell, D.
    Gill, H. S.
    Murray, D. W.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08): : 1072 - 1078
  • [7] Insufficient Acetabular Version Increases Blood Metal Ion Levels after Metal-on-metal Hip Resurfacing
    Hart, Alister J.
    Skinner, John A.
    Henckel, Johann
    Sampson, Barry
    Gordon, Fabiana
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (09) : 2590 - 2597
  • [8] Cup Anteversion in Hip Resurfacing: Validation of EBRA and the Presentation of a Simple Clinical Grading System
    Langton, David J.
    Sprowson, Andrew P.
    Mahadeva, Dhirendra
    Bhatnagar, Sharad
    Holland, James P.
    Nargol, Antoni V. F.
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (04) : 607 - 613
  • [9] Pelvis and total hip arthroplasty acetabular component orientations in sitting and standing positions: Measurements reproductibility with EOS imaging system versus conventional radiographies
    Lazennec, J. Y.
    Rousseau, M. A.
    Rangel, A.
    Gorin, M.
    Belicourt, C.
    Brusson, A.
    Catonne, Y.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (04) : 373 - 380
  • [10] Influence of the sagittal balance of the spine on the anterior pelvic plane and on the acetabular orientation
    Legaye, Jean