Diagnostic accuracy and associated complications of percutaneous computed tomography guided core needle biopsy of pulmonary lesions using coaxial technique

被引:2
作者
Sattar, Amjad [1 ]
Khan, Sohail Ahmed [1 ]
Al-Qamari, Nauman [1 ]
Adel, Hatem [1 ]
Adil, Syed Omair [2 ]
机构
[1] Dow Univ Hlth Sci, Dow Inst Radiol, Karachi, Pakistan
[2] Dow Univ Hlth Sci, Dept Res, Karachi, Pakistan
关键词
Spiral Computed Tomography; Core Needle Biopsy; Lung; Metastasis; LUNG-BIOPSY; PNEUMOTHORAX; RISK;
D O I
10.5455/JPMA.272057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was conducted to determine the diagnostic accuracy of CT-guided core needle biopsy (CNB) using coaxial technique of pulmonary lesions, its complications and factors affecting them. A total of 122 patients with suspected lung malignancy underwent CT-guided CNB. Final diagnosis was confirmed by histopathology. There were 84 ( 89.4%) true positive while 26 ( 92.9%) true negative cases. Diagnostic accuracy, sensitivity, specificity, PPV, NPV, and overall diagnostic accuracy were 97.67%, 72.22%, 89.36%, 92.86% and 90.16% respectively. Pneumothorax was the only complication observed in 10 (8.2%) patients. The odds of pneumothorax was found to be 10.72 times higher among patients with. 2.5cm of size of lesions (AOR 10.72, 95% CI 1.49-76.77) while 86% lower among patients having prone position (AOR 0.14, 95% CI 0.021-0.96). Results indicate that percutaneous CT guided biopsy of pulmonary lesions using coaxial technique is a safe procedure with a high diagnostic accuracy and lesser risk of major complications.
引用
收藏
页码:1711 / 1713
页数:3
相关论文
共 10 条
[1]   CT-guided lung biopsy: Factors influencing diagnostic yield and complication rate [J].
Anderson, JM ;
Murchison, J ;
Patel, D .
CLINICAL RADIOLOGY, 2003, 58 (10) :791-797
[2]   Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions [J].
de Lima, Cristiano Dias ;
Nunes, Rodolfo Acatauassu ;
Saito, Eduardo Haruo ;
Higa, Claudio ;
Fernando Cardona, Zanier Jose ;
dos Santos, Denise Barbosa .
JORNAL BRASILEIRO DE PNEUMOLOGIA, 2011, 37 (02) :209-216
[3]  
Feragalli Beatrice, 2003, Radiol Med, V105, P266
[4]   Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy [J].
Khan, M. F. ;
Straub, R. ;
Moghaddam, S. R. ;
Maataoui, A. ;
Gurung, J. ;
Wagner, T. O. F. ;
Ackermann, H. ;
Thalhammer, A. ;
Vogl, T. J. ;
Jacobi, V. .
EUROPEAN RADIOLOGY, 2008, 18 (07) :1356-1363
[5]   Analysis of factors influencing accuracy and complications in CT-guided lung biopsy [J].
Nakatani, Miyuki ;
Tanigawa, Noboru ;
Kariya, Shuji ;
Komemushi, Atsushi ;
Yagi, Rie ;
Sawada, Satoshi .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2012, 21 (06) :415-422
[6]   The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy - The angle of the needle trajectory is a novel predictor [J].
Saji, H ;
Nakamura, H ;
Tsuchida, T ;
Tsuboi, M ;
Kawate, N ;
Konaka, C ;
Kato, H .
CHEST, 2002, 121 (05) :1521-1526
[7]   Accuracy of transthoracic sonography in detection of pneumothorax after sonographically guided lung biopsy: Prospective comparison with chest radiography [J].
Sartori, Sergio ;
Tombesi, Paola ;
Trevisani, Lucio ;
Nielsen, Ingrid ;
Tassinari, Davide ;
Abbasciano, Vincenzo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) :37-41
[8]   Complications of CT-Guided Percutaneous Needle Biopsy of the Chest: Prevention and Management [J].
Wu, Carol C. ;
Maher, Michael M. ;
Shepard, Jo-Anne O. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :W678-W682
[9]   Risk factors of pneumothorax and bleeding - Multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies [J].
Yeow, KM ;
Su, IH ;
Pan, KT ;
Tsay, PK ;
Lui, KW ;
Cheung, YC ;
Chou, ASB .
CHEST, 2004, 126 (03) :748-754
[10]   Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: Retrospective analysis of 631 procedures [J].
Yeow, KM ;
Tsay, PK ;
Cheung, YC ;
Lui, KW ;
Pan, KT ;
Chou, ASB .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (05) :581-588