Sutureless human sclera donor patch graft for Ahmed glaucoma valve

被引:23
|
作者
Zeppa, Lucio [1 ]
Romano, Mario R. [2 ]
Capasso, Luigi [3 ]
Tortori, Achille [3 ]
Majorana, Mara A. [1 ]
Costagliola, Ciro [2 ]
机构
[1] Presidio Osped Giuseppe Moscati, Unite Operat Oculist, Avellino, Italy
[2] Univ Molise, Dipartimento Sci Salute, Campobasso, Italy
[3] Presidio Osped Pellegrini, Unite Operat Oculist, Naples, Italy
关键词
Ahmed glaucoma valve; Patch graft; Refractory glaucoma; Sclera donor; CONJUNCTIVAL CLOSURE; PEDIATRIC GLAUCOMA; STRABISMUS SURGERY; FIBRIN GLUE; IMPLANT; INSERTION; OUTCOMES; VICRYL;
D O I
10.1177/112067211002000302
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To report the safety and effectiveness of a sutureless human sclera donor patch graft covering the subconjunctival portion of glaucoma drainage implant tube to prevent its erosion throughout the overlying conjunctiva. Methods. This was a prospective pilot study. Fifteen eyes of 15 consecutive patients not responsive to medical and to not-implant surgical glaucoma treatment underwent Ahmed glaucoma valve (AGV) implant surgery with sutureless human sclera donor patch graft. The surgical procedure included AVG implant placed 8 mm behind the corneal limbus and fixed to the sclera with two 9-0 black nylon sutures. The tube was passed through the scleral tunnel, parallel to the corneal limbus, and shortened at the desired length. The anterior part of the tube was covered with human donor scleral graft and kept in place with fibrin glue (Tissue Coll (R)) under the conjunctiva. Examinations were scheduled at baseline and then at 1 week and 1, 3, 6, and 12 months after surgery. Results. At 12-month follow-up, the best-corrected visual acuity did not significantly improve from baseline 0.78+/-1.2 logMAR, whereas mean intraocular pressure significantly decreased from preoperative values of 29.8 (SD 8.4) mmHg. In all cases, the scleral patch was found in place at each check during the follow-up period. No conjunctival erosion over the AGV tube nor sign of endophthalmitis was recorded at any time during the follow-up period. Conclusions. AVG implant surgery with sutureless human sclera donor patch graft represents an effective and relatively safe surgical procedure for complicated glaucomas, avoiding conjunctival erosions over the AGV tube. (Eur J Ophthalmol 2010; 20: 546-51)
引用
收藏
页码:546 / 551
页数:6
相关论文
共 50 条
  • [21] Graft survival and glaucoma outcome after simultaneous penetrating keratoplasty and Ahmed glaucoma valve implant
    Al-Torbak, A
    CORNEA, 2003, 22 (03) : 194 - 197
  • [22] Short-term Results of Using Lamellar Corneo-scleral Patch Graft for the Ahmed Glaucoma Valve Implant Surgery
    Dennis S.C.Lam
    Wah Cheuk
    Jimmy S.M.Lai
    眼科学报, 1997, (03) : 109 - 112
  • [23] Ahmed glaucoma valve in various etiologies of refractory glaucoma: Surgical outcomes and success factors
    Sahyoun, M. A.
    Farhat, R. G.
    Nehme, J. C. B.
    Jalkh, A. E.
    Azar, G. G.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2017, 40 (09): : 770 - 776
  • [24] Evaluation of the tightness of contact between limbal sclera tunnel and tube following Ahmed glaucoma valve implantation
    Hollo, Gabor
    Naghizadeh, Farzaneh
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (06) : 905 - 908
  • [25] Effect of a Pericardium Graft Inserted Adjacent to the Endplate in the Ahmed Glaucoma Valve Implantation
    Oh, Si Eun
    Jung, Kyoung In
    Shin, Hee Jong
    Ryu, Hee Kyung
    Kim, Seong Ah
    Park, Hae-Young Lopilly
    Park, Chan Kee
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (19)
  • [26] Outcomes of Silicone Ahmed Glaucoma Valve Implantation in Refractory Pediatric Glaucoma
    Senthil, Sirisha
    Turaga, Kiranmaye
    Mohammed, Hasnat A.
    Krishnamurthy, Rashmi
    Badakere, Swathi
    Dikshit, Siddharth
    Choudhari, Nikhil
    Mandal, Anil K.
    Garudadri, Chandra S.
    JOURNAL OF GLAUCOMA, 2018, 27 (09) : 769 - 775
  • [27] Long-term success of ahmed glaucoma valve in refractory glaucoma
    Mahmut Kaya
    Zeynep Ozbek
    Aylin Yaman
    Ismet Durak
    International Journal of Ophthalmology, 2012, (01) : 108 - 112
  • [28] Is Ahmed Glaucoma Valve Consistent in Performance?
    Choudhari, Nikhil S.
    Badakere, Swathi Vallabh
    Richhariya, Ashutosh
    Chittajallu, Sai Naga Sri Harsha
    Senthil, Sirisha
    Garudadri, Chandra Sekhar
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (03):
  • [29] The use of Ahmed glaucoma valve in the management of pediatric glaucoma
    Balekudaru, Shantha
    Vadalkar, Juhie
    George, Ronnie
    Vijaya, Lingam
    JOURNAL OF AAPOS, 2014, 18 (04): : 351 - 356
  • [30] Ahmed Glaucoma Valve in Refractory Glaucoma: A Retrospective Study
    Kumar, Suresh
    Thakur, Sahil
    Sharma, Madhu
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (04) : NC8 - NC11