Sutureless human sclera donor patch graft for Ahmed glaucoma valve

被引:23
|
作者
Zeppa, Lucio [1 ]
Romano, Mario R. [2 ]
Capasso, Luigi [3 ]
Tortori, Achille [3 ]
Majorana, Mara A. [1 ]
Costagliola, Ciro [2 ]
机构
[1] Presidio Osped Giuseppe Moscati, Unite Operat Oculist, Avellino, Italy
[2] Univ Molise, Dipartimento Sci Salute, Campobasso, Italy
[3] Presidio Osped Pellegrini, Unite Operat Oculist, Naples, Italy
关键词
Ahmed glaucoma valve; Patch graft; Refractory glaucoma; Sclera donor; CONJUNCTIVAL CLOSURE; PEDIATRIC GLAUCOMA; STRABISMUS SURGERY; FIBRIN GLUE; IMPLANT; INSERTION; OUTCOMES; VICRYL;
D O I
10.1177/112067211002000302
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To report the safety and effectiveness of a sutureless human sclera donor patch graft covering the subconjunctival portion of glaucoma drainage implant tube to prevent its erosion throughout the overlying conjunctiva. Methods. This was a prospective pilot study. Fifteen eyes of 15 consecutive patients not responsive to medical and to not-implant surgical glaucoma treatment underwent Ahmed glaucoma valve (AGV) implant surgery with sutureless human sclera donor patch graft. The surgical procedure included AVG implant placed 8 mm behind the corneal limbus and fixed to the sclera with two 9-0 black nylon sutures. The tube was passed through the scleral tunnel, parallel to the corneal limbus, and shortened at the desired length. The anterior part of the tube was covered with human donor scleral graft and kept in place with fibrin glue (Tissue Coll (R)) under the conjunctiva. Examinations were scheduled at baseline and then at 1 week and 1, 3, 6, and 12 months after surgery. Results. At 12-month follow-up, the best-corrected visual acuity did not significantly improve from baseline 0.78+/-1.2 logMAR, whereas mean intraocular pressure significantly decreased from preoperative values of 29.8 (SD 8.4) mmHg. In all cases, the scleral patch was found in place at each check during the follow-up period. No conjunctival erosion over the AGV tube nor sign of endophthalmitis was recorded at any time during the follow-up period. Conclusions. AVG implant surgery with sutureless human sclera donor patch graft represents an effective and relatively safe surgical procedure for complicated glaucomas, avoiding conjunctival erosions over the AGV tube. (Eur J Ophthalmol 2010; 20: 546-51)
引用
收藏
页码:546 / 551
页数:6
相关论文
共 50 条
  • [1] Outcomes of using a sutureless bovine pericardial patch graft for Ahmed glaucoma valve implantation
    Quaranta, Luciano
    Riva, Ivano
    Floriani, Irene C.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (05) : 738 - 742
  • [2] Long -term success of ahmed glaucoma valve in refractory glaucoma
    Kaya, Mahmut
    Ozbek, Zeynep
    Yaman, Aylin
    Durak, Ismet
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2012, 5 (01) : 108 - 112
  • [3] Outcomes of Sutureless Ahmed Glaucoma Valve Surgery: A Retrospective Study
    Nicholas E. Tan
    Shannon X. Chen
    Alexander H. Fang
    Nathan M. Radcliffe
    Ophthalmology and Therapy, 2022, 11 : 2083 - 2100
  • [4] Outcomes of Sutureless Ahmed Glaucoma Valve Surgery: A Retrospective Study
    Tan, Nicholas E.
    Chen, Shannon X.
    Fang, Alexander H.
    Radcliffe, Nathan M.
    OPHTHALMOLOGY AND THERAPY, 2022, 11 (06) : 2083 - 2100
  • [5] Use of Autologous Scleral Graft in Ahmed Glaucoma Valve Surgery
    Wolf, Alvit
    Hod, Yair
    Buckman, Gila
    Stein, Nili
    Geyer, Orna
    JOURNAL OF GLAUCOMA, 2016, 25 (04) : 365 - 370
  • [6] Evaluation of pericardium patch graft thickness in patients with Ahmed glaucoma valve implantation: an anterior segment OCT study
    Akbas, Yusuf Berk
    Alagoz, Nese
    Sari, Cem
    Altan, Cigdem
    Yasar, Tekin
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2024, 68 (03) : 192 - 199
  • [7] Lamellar Donor Cornea in Ahmed Glaucoma Valve Surgery
    Kurnaz, Ekrern
    Kubaloglu, Anil
    Koytak, Nihal Asif
    Asik, Nihal
    Ozdemir, Burak
    Erol, Kazim
    Ozerturk, Yusuf
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2009, 39 (02): : 103 - 110
  • [8] Safety and efficacy of ahmed valve on intractable glaucoma in Saudi population
    Osman, Essam A.
    Alkheraiji, Norah F.
    Abouammoh, Mohammad A.
    Mousa, Ahmed
    Al-Obeidan, Saleh
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2020, 27 (01) : 40 - 46
  • [9] Evaluation of pericardium patch graft thickness in patients with Ahmed glaucoma valve implantation: an anterior segment OCT study
    Yusuf Berk Akbas
    Nese Alagoz
    Cem Sari
    Cigdem Altan
    Tekin Yasar
    Japanese Journal of Ophthalmology, 2024, 68 : 192 - 199
  • [10] Ahmed Glaucoma Valve Revision Versus Visco-Trabeculotomy After Failed Ahmed Glaucoma Valve in Refractory Pediatric Glaucoma
    Elwehidy, Ahmed S.
    Badawi, Amani E.
    Hagras, Sherein M.
    Bayoumi, Nader H. L.
    JOURNAL OF GLAUCOMA, 2019, 28 (04) : 307 - 312