A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging

被引:13
作者
Deng, Luzhen [1 ,2 ]
Wei, Biao [1 ]
He, Peng [1 ,3 ]
Zhang, Yi [4 ]
Feng, Peng [1 ,3 ]
机构
[1] Chongqing Univ, Key Lab Optoelect Technol & Syst, Minist Educ, Room 1311,Main Bldg,Shapingba St, Chongqing 400044, Peoples R China
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[3] Chongqing Univ, Engn Res Ctr Ind Computed Tomog Nondestruct Testi, Minist Educ, Chongqing 400044, Peoples R China
[4] Sichuan Univ, Coll Comp Sci, Chengdu 610065, Sichuan, Peoples R China
来源
INTERNATIONAL JOURNAL OF NANOMEDICINE | 2018年 / 13卷
基金
中国国家自然科学基金;
关键词
Geant4; Monte Carlo simulation; multi-pinhole; X-ray fluorescence computed tomography; gold nanoparticles; bioimaging modality; NANOPARTICLE-LOADED OBJECTS; EMISSION;
D O I
10.2147/IJN.S179875
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Background: X-ray fluorescence (XRF) computed tomography (XFCT) has shown promise for molecular imaging of metal nanoparticles such as gold nanoparticles (GNPs) and benchtop XFCT is under active development due to its easy access, low-cost instrumentation and operation. Purpose: To validate the performance of a Geant4-based Monte Carlo (MC) model of a benchtop multi-pinhole XFCT system for quantitative imaging of GNPs. Methods: The MC mode consisted of a fan-beam x-ray source (125 kVp), which was used to stimulate the emission of XRF from the GNPs, a phantom (3 cm in diameter) which included six or nine inserts (3 mm in diameter), each of which contained the same (1 wt. %) or various (0.08-1 wt. %) concentrations of GNPs, a multi-pinhole collimator which could acquire multiple projections simultaneously and a one-sided or two-sided two-dimensional (2D) detector. Various pinhole diameters (3.7, 2, 1, 0.5 and 0.25 mm) and various particle numbers (20, 40, 80 and 100 billion) were simulated and the results for single pinhole and multi-pinhole (9 pinholes) imaging were compared. Results: The image resolution for a 1 mm multi-pinhole was between 0.88 and 1.38 mm. The detection limit for multi-pinhole operation was about 0.09 wt. %, while that for the single pinhole was about 0.13 wt. %. For a fixed number of pinholes, noise increased with decreasing number of photons. Conclusion: The MC mode could acquire 2D slice images of the object without rotation and demonstrated that a multi-pinhole XFCT imaging system could be a potential bioimaging modality for nanomedical applications.
引用
收藏
页码:7207 / 7216
页数:10
相关论文
共 23 条
  • [1] Ahmed MF, IEEE T MED IMAGING
  • [2] A NEW TOMOGRAPHIC DEVICE BASED ON THE DETECTION OF FLUORESCENT X-RAYS
    CESAREO, R
    MASCARENHAS, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3) : 669 - 672
  • [3] TRACE-ELEMENT ANALYSIS IN BIOLOGICAL SAMPLES BY USING XRF SPECTROMETRY WITH SECONDARY RADIATION
    CESAREO, R
    VIEZZOLI, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (11) : 1209 - 1218
  • [4] X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays
    Cheong, Seong-Kyun
    Jones, Bernard L.
    Siddiqi, Arsalan K.
    Liu, Fang
    Manohar, Nivedh
    Cho, Sang Hyun
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03) : 647 - 662
  • [6] Dickerscheid D, 2013, EJNMMI RES, V3, DOI 10.1186/2191-219X-3-21
  • [7] Analytic Comparison Between X-Ray Fluorescence CT and K-Edge CT
    Feng, Peng
    Cong, Wenxiang
    Wei, Biao
    Wang, Ge
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (03) : 975 - 985
  • [8] Experimental demonstration of novel imaging geometries for x-ray fluorescence computed tomography
    Fu, Geng
    Meng, Ling-Jian
    Eng, Peter
    Newville, Matt
    Vargas, Phillip
    La Riviere, Patrick
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Jiang S., 2017, P 14 INT M FULLY 3 D, P348
  • [10] Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beams
    Jones, Bernard L.
    Manohar, Nivedh
    Reynoso, Francisco
    Karellas, Andrew
    Cho, Sang Hyun
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (23) : N457 - N467