Improved focal liver lesion detection: Comparison of single-shot spin-echo echo-planar and superparamagnetic iron oxide (SPIO)-enhanced MRI

被引:26
作者
Coenegrachts, Kenneth [1 ]
Orlent, Hans [2 ]
ter Beek, Leon [3 ]
Haspeslagh, Marc [4 ]
Bipat, Shandra [5 ]
Stoker, Jaap [5 ]
Rigauts, Hans [1 ]
机构
[1] Dept Radiol, B-8000 Brugge, Belgium
[2] Dept Internal Med, B-8000 Brugge, Belgium
[3] Philips Med Syst, Best, Netherlands
[4] Hosp Adm & Stat, Brugge, Belgium
[5] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
关键词
liver; lesion; MRI; SSSE-EPI; SPIO-enhanced imaging;
D O I
10.1002/jmri.21247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively compare single-shot spin-echo echo-planar imaging (SSSE-EPI) using b = 0, 10, 150, and 400 seconds/mm(2) with standard MRI techniques after intravenous super paramagnetic iron oxide (SPIO) in the detection and characterization of focal liver lesions with focus on small (< 10 mm) focal liver lesions. Materials and Methods: A total of 25 patients suspected for colorectal liver metastases were included. Number of detected lesions was evaluated. Image quality was compared between SSSE-EPI sequence and post-SPIO (fat-suppressed T1-weighted [T1w] gradient echo [GE], T2-weighted [T2w] turbo spin echo [TSE] and T2* GE) sequences using rank order statistic (RIDIT). Lesion characterization was performed for SSSE-EPI and for all remaining sequences pre- and post-SPIO. Reference standard comprised surgery, biopsy, and/or follow-up. Results: Reference standard demonstrated 25 hemangiomas and 70 metastases. Best lesion detection respectively best image quality (P < 0.05) was achieved with SSSE-EPI (b = 10 seconds/mm(2)) post-SPIO T1w GE and T2w turbo spin echo. Lesion characterization using all sequences pre-and post-SPIO performed best for lesion characterization compared with SSSE-EPI. Conclusion: This preliminary study shows the potential of SSSE-EPI as a stand-alone sequence for the detection of liver hemangiomas and metastases when compared with SPIO-enhanced imaging. Sequences pre- and post-SPIO are needed for qualitative lesion characterization.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 20 条
[1]   Colorectal liver metastases: CT, MR imaging, and PET for diagnosis - Meta-analysis [J].
Bipat, S ;
van Leeuwen, MS ;
Comans, EFI ;
Pijl, MEJ ;
Bossuyt, PMM ;
Zwinderman, AH ;
Stoker, J .
RADIOLOGY, 2005, 237 (01) :123-131
[2]   HOW TO USE RIDIT ANALYSIS [J].
BROSS, IDJ .
BIOMETRICS, 1958, 14 (01) :18-38
[3]   Improved focal liver lesion detection:: comparison of single-shot diffusion-weighted echoplanar and single-shot T2 weighted turbo spin echo techniques [J].
Coenegrachts, K. ;
Delanote, J. ;
Ter Beek, L. ;
Haspeslagh, M. ;
Bipat, S. ;
Stoker, J. ;
Van Kerkhove, F. ;
Steyaert, L. ;
Rigauts, H. ;
Casselman, J. W. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (955) :524-531
[4]   HEPATIC TUMORS - DETECTION AND CHARACTERIZATION AT 1-T MR-IMAGING ENHANCED WITH AMI-25 [J].
DENYS, A ;
ARRIVE, L ;
SERVOIS, V ;
DUBRAY, B ;
NAJMARK, D ;
SIBERT, A ;
MENU, Y .
RADIOLOGY, 1994, 193 (03) :665-669
[5]   ENHANCEMENT OF LIVER HEMANGIOMAS ON T1-WEIGHTED MR SE IMAGES BY SUPERPARAMAGNETIC IRON-OXIDE PARTICLES [J].
GRANGIER, C ;
TOURNIAIRE, J ;
MENTHA, G ;
SCHIAU, R ;
HOWARTH, N ;
CHACHUAT, A ;
GROSSHOLZ, M ;
TERRIER, F .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (06) :888-896
[6]   Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study [J].
Hussain, SM ;
De Becker, J ;
Hop, WCJ ;
Dwarkasing, S ;
Wielopolski, PA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) :219-229
[7]   Diagnostic efficacy and safety of MRI of the liver with superparamagnetic iron oxide particles (SH U 555 A) [J].
Kehagias, DT ;
Gouliamos, AD ;
Smyrniotis, V ;
Vlahos, LJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :595-601
[8]   Characterization of focal hepatic lesions with ferumoxides-enhanced MR imaging: Utility of T1-weighted spoiled gradient recalled echo images using different echo times [J].
Kim, JH ;
Kim, MJ ;
Suh, SH ;
Chung, JJ ;
Yoo, HS ;
Lee, JT .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (05) :573-583
[9]   Detection and characterization of liver metastases: 16-slice multidetector computed tomography versus superparamagnetic iron oxide-enhanced magnetic resonance imaging [J].
Kim, Young Kon ;
Ko, Seog Wan ;
Hwang, Seung Bae ;
Kim, Chong Soo ;
Yu, Hee Chul .
EUROPEAN RADIOLOGY, 2006, 16 (06) :1337-1345
[10]  
Morana Giovanni, 2002, Top Magn Reson Imaging, V13, P117, DOI 10.1097/00002142-200206000-00002