Investigating sources of inaccuracy in wearable optical heart rate sensors

被引:387
作者
Bent, Brinnae [1 ]
Goldstein, Benjamin A. [2 ]
Kibbe, Warren A. [2 ]
Dunn, Jessilyn P. [1 ,2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[2] Duke Univ, Dept Bioinformat & Biostat, Durham, NC 27708 USA
关键词
SKIN COLOR; ACCURACY; HEALTH;
D O I
10.1038/s41746-020-0226-6
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
As wearable technologies are being increasingly used for clinical research and healthcare, it is critical to understand their accuracy and determine how measurement errors may affect research conclusions and impact healthcare decision-making. Accuracy of wearable technologies has been a hotly debated topic in both the research and popular science literature. Currently, wearable technology companies are responsible for assessing and reporting the accuracy of their products, but little information about the evaluation method is made publicly available. Heart rate measurements from wearables are derived from photoplethysmography (PPG), an optical method for measuring changes in blood volume under the skin. Potential inaccuracies in PPG stem from three major areas, includes (1) diverse skin types, (2) motion artifacts, and (3) signal crossover. To date, no study has systematically explored the accuracy of wearables across the full range of skin tones. Here, we explored heart rate and PPG data from consumer- and research-grade wearables under multiple circumstances to test whether and to what extent these inaccuracies exist. We saw no statistically significant difference in accuracy across skin tones, but we saw significant differences between devices, and between activity types, notably, that absolute error during activity was, on average, 30% higher than during rest. Our conclusions indicate that different wearables are all reasonably accurate at resting and prolonged elevated heart rate, but that differences exist between devices in responding to changes in activity. This has implications for researchers, clinicians, and consumers in drawing study conclusions, combining study results, and making health-related decisions using these devices.
引用
收藏
页数:9
相关论文
共 59 条
[41]   Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise? [J].
Reis, Victor M. ;
Vianna, Jeferson M. ;
Barbosa, Tiago M. ;
Garrido, Nuno ;
Vilaca Alves, Jose ;
Carneiro, Andre L. ;
Aidar, Felipe J. ;
Novaes, Jefferson .
PLOS ONE, 2019, 14 (08)
[42]   SKIN COLOR AND EAR OXIMETRY [J].
RIES, AL ;
PREWITT, LM ;
JOHNSON, JJ .
CHEST, 1989, 96 (02) :287-290
[43]   Fitzpatrick skin typing: Applications in dermatology [J].
Sachdeva, Silonie .
INDIAN JOURNAL OF DERMATOLOGY VENEREOLOGY & LEPROLOGY, 2009, 75 (01) :93-96
[44]   Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients [J].
Sartor, Francesco ;
Gelissen, Jos ;
Van Dinther, Ralph ;
Roovers, David ;
Papini, Gabriele B. ;
Coppola, Giuseppe .
BMC SPORTS SCIENCE MEDICINE AND REHABILITATION, 2018, 10
[45]   An Overview of Heart Rate variability Metrics and Norms [J].
Shaffer, Fred ;
Ginsberg, J. P. .
FRONTIERS IN PUBLIC HEALTH, 2017, 5
[46]   Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort [J].
Shcherbina, Anna ;
Mattsson, C. Mikael ;
Waggott, Daryl ;
Salisbury, Heidi ;
Christle, Jeffrey W. ;
Hastie, Trevor ;
Wheeler, Matthew T. ;
Ashley, Euan A. .
JOURNAL OF PERSONALIZED MEDICINE, 2017, 7 (02)
[47]   Wearable Photoplethysmographic Sensors-Past and Present [J].
Tamura, Toshiyo ;
Maeda, Yuka ;
Sekine, Masaki ;
Yoshida, Masaki .
ELECTRONICS, 2014, 3 (02) :282-302
[48]  
Tautan AM, 2015, IEEE ENG MED BIO, P6146, DOI 10.1109/EMBC.2015.7319795
[49]   Correlation Between Skin Color Evaluation by Skin Color Scale Chart and Narrowband Reflectance Spectrophotometer [J].
Treesirichod, Arucha ;
Chansakulporn, Somboon ;
Wattanapan, Pattra .
INDIAN JOURNAL OF DERMATOLOGY, 2014, 59 (04) :339-342
[50]   In vivo determination of skin near-infrared optical properties using diffuse optical spectroscopy [J].
Tseng, Sheng-Hao ;
Grant, Alexander ;
Durkin, Anthony J. .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (01)