chromatography; size exclusion; gel permeation; macromolecules; separation; detection; characterization; PERFORMANCE LIQUID-CHROMATOGRAPHY; LIGHT-SCATTERING DETECTION; MOLECULAR-WEIGHT DETERMINATION; GEL-PERMEATION CHROMATOGRAPHY; TIME-OF-FLIGHT; MASS-SPECTROMETRY; CAPILLARY ELECTROPHORESIS; COAL DERIVATIVES; POLYMERS; MATRIX;
D O I
10.1016/S0165-022X(03)00053-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present state of the chromatographic techniques based on differentiation of solutes according to their molecular sizes is briefly surveyed. Attention is centred on high-performance techniques applied to purification and characterization of natural macromolecules, and on discussion of the chromatographic approaches to the determination of the molecular masses and molecular mass distributions of both natural and synthetic polymers. The basic requirements on the selection of the separation system and the experimental conditions are summarized, demonstrated on a few examples and critically evaluated. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 40 条
[1]   ERRORS CAUSED BY FLOWRATE VARIATION IN HIGH-PERFORMANCE SIZE EXCLUSION CHROMATOGRAPHY (GPC) [J].
BLY, DD ;
STOKLOSA, HJ ;
KIRKLAND, JJ ;
YAU, WW .
ANALYTICAL CHEMISTRY, 1975, 47 (11) :1810-1813
[2]  
BRAUN M, 2001, THESIS CHARLES U PRA
[3]  
DETERMANN H, 1969, GEL CHROMATOGRAPHY
[4]   PRACTICAL ONLINE DETERMINATION OF BIOPOLYMER MOLECULAR-WEIGHTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CLASSICAL LIGHT-SCATTERING DETECTION [J].
DOLLINGER, G ;
CUNICO, B ;
KUNITANI, M ;
JOHNSON, D ;
JONES, R .
JOURNAL OF CHROMATOGRAPHY, 1992, 592 (1-2) :215-228
[5]  
Dubin P.L., 1988, Aqueous size-exclusion chromatography
[6]  
FISHER L, 1980, GEL FILTRATION CHROM
[7]  
Hunt B.J., 1989, Size Exclusion Chromatography
[8]   Absolute calibration of size exclusion chromatography for coal derivatives through MALDI-ms [J].
Johnson, BR ;
Bartle, KD ;
Domin, M ;
Herod, AA ;
Kandiyoti, R .
FUEL, 1998, 77 (9-10) :933-945
[9]   N-methyl-2-pyrrolidinone as a mobile phase in the size-exclusion chromatography of coal derivatives [J].
Johnson, BR ;
Bartle, KD ;
Herod, AA ;
Kandiyoti, R .
JOURNAL OF CHROMATOGRAPHY A, 1997, 758 (01) :65-74
[10]   MOLECULAR-MASS DETERMINATION OF LOW-MOLECULAR-MASS HEPARINS - APPLICATION OF WIDE COLLECTION ANGLE MEASUREMENTS OF LIGHT-SCATTERING USING A HIGH-PERFORMANCE GEL-PERMEATION CHROMATOGRAPHIC SYSTEM EQUIPPED WITH A LOW-ANGLE LASER LIGHT-SCATTERING PHOTOMETER [J].
KOMATSU, H ;
YOSHII, K ;
ISHIMITSU, S ;
OKADA, S ;
TAKAHATA, T .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01) :17-24