Sputum rheology changes in cystic fibrosis lung disease following two different types of physiotherapy - Flutter vs autogenic drainage

被引:123
作者
App, EM
Kieselmann, R
Reinhardt, D
Lindemann, H
Dasgupta, B
King, M
Brand, P
机构
[1] Univ Freiburg, Dept Internal Med, Div Pneumol, Cyst Fibrosis Outpatient Clin, D-79106 Freiburg, Germany
[2] GSF, Res Ctr Environm & Hlth, Inst Inhalat Biol, Munich, Germany
[3] Univ Munich, Cyst Fibrosis Physiotherapy Ctr, Munich, Germany
[4] Univ Munich, Div Pediat Pneumol, Munich, Germany
[5] Univ Giessen, Div Pediat Pneumol, Giessen, Germany
[6] Univ Alberta, Pulm Res Grp, Edmonton, AB, Canada
关键词
autogenic drainage; cystic fibrosis; Flutter; mucus clearance; mucus viscoelasticity; physiotherapy; pulmonary function;
D O I
10.1378/chest.114.1.171
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The aim of the present study was to investigate the efficacy of two frequently used physiotherapies (PTs) for the removal of bronchial secretions in cystic fibrosis (CF) lung disease: autogenic drainage (AD) and the Flutter (Desitin iri Germany). AD is believed to improve mucus clearance from peripheral to central airways due to airway caliber changes in combination with a special breathing technique, The Flutter is an easy-to-use physiotherapy device based on oscillations of a steel ball during expiration through a pipe-type device. Materials and methods: To evaluate the acute and chronic physiotherapy effects of these two techniques, 14 CF patients underwent either twice daily AD or Flutter treatment for 4 consecutive weeks in a randomized crossover design. Prior to each therapy interval, for a 1-week wash-out period, no PT was administered, but patients continued regular medication, At the beginning and end of each 4-week interval, pulmonary function was measured before and after an acute 30-min therapy. At the end of the PT session, sputum was collected, weighed, and deep frozen until analyzed. The viscoelasticity of the sputum was evaluated using a magnetic microrheometer. Results: No significant changes were noted for FVC, FEV1, or sputum volume throughout the study. Sputum viscoelasticity (rigidity index), however, was significantly lower (p<0.01) after therapy with the Flutter in comparison with AD, predicting improvements in mucociliary and cough clearability of the secretions, In a companion in vitro experiment, oscillations generated by passing humidified air over CF sputum lining an acrylic tube connected to a Flutter device were found to decrease sputum elasticity, as measured by a filancemeter.These findings suggest that applied oscillations are capable of decreasing mucus viscoelasticity within the airways at frequencies and amplitudes achievable with the Flutter device, and provide direct evidence that PT can I educe the viscoelasticity of sputum.
引用
收藏
页码:171 / 177
页数:7
相关论文
共 21 条
  • [1] [Anonymous], 1991, RESP CARE
  • [2] App E. M., 1994, Atemwegs- und Lungenkrankheiten, V20, P363
  • [3] APP EM, 1990, BIORHEOLOGY, V27, P515
  • [4] ACUTE AND LONG-TERM AMILORIDE INHALATION IN CYSTIC-FIBROSIS LUNG-DISEASE - A RATIONAL APPROACH TO CYSTIC-FIBROSIS THERAPY
    APP, EM
    KING, M
    HELFESRIEDER, R
    KOHLER, D
    MATTHYS, H
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1990, 141 (03): : 605 - 612
  • [5] APP EM, 1993, EUR RESPIR J, V6, P67
  • [6] EFFECTS OF COMBINED TREATMENT WITH RHDNASE AND AIR-FLOW OSCILLATIONS ON SPINNABILITY OF CYSTIC-FIBROSIS SPUTUM IN-VITRO
    DASGUPTA, B
    TOMKIEWICZ, RP
    BOYD, WA
    BROWN, NE
    KING, M
    [J]. PEDIATRIC PULMONOLOGY, 1995, 20 (02) : 78 - 82
  • [7] KIESELMANN R, 1994, PHYSIOTHERAPIE MUKOV
  • [8] KING M, 1987, BIORHEOLOGY, V24, P589
  • [9] CLEARANCE OF MUCUS BY SIMULATED COUGH
    KING, M
    BROCK, G
    LUNDELL, C
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (06) : 1776 - 1782
  • [10] KING M, 1979, BIORHEOLOGY, V16, P57