摘要
Several methods have been proposed over the past few decades as a solution to the brain sources localization problem using EEG signals. In this paper the performances of different brain source localization techniques, including the Minimum Norm Estimates (MNE), Low Resolution Electrical Tomography (LORETA) and Multiple Sparse Priors (MSP), are assessed and compared. Due to the lack of the baseline, the evaluation is conducted using simulated dipolar source distributions constrained to the cortical surface. We corroborate in the superiority of MSP over LORETA and MNE in accurately estimating the locations of the simulated sources, however we found that MNE and LORETA may account as a better measure for asymmetric activations.
引用
收藏
页码:942 / 947
页数:6
相关论文
共 50 条
  • [41] EEG/MEG Source Localization Using Source Deflated Matching Pursuit
    Wu, Shun Chi
    Swindlehurst, A. Lee
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 6572 - 6575
  • [42] EEG Source Localization Using the Inverse Problem Methods
    Khemakhem, Rafik
    Zouch, Wassim
    Ben Hamida, Ahmed
    Taleb-Ahmed, Abdelmalik
    Feki, Imed
    INTERNATIONAL JOURNAL OF COMPUTER SCIENCE AND NETWORK SECURITY, 2009, 9 (04): : 408 - 415
  • [43] Robust EEG Source Localization Using Subspace Principal Vector Projection Technique
    Giri, Amita
    Kumar, Lalan
    Gandhi, Tapan
    28TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO 2020), 2021, : 1075 - 1079
  • [44] Evaluation of spatial resolution and noise sensitivity of sLORETA method for EEG source localization using low-density headsets
    Saha, Sajib
    Nesterets, Ya I.
    Tahtali, M.
    Gureyev, T. E.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (04):
  • [45] EEG source localization sensitivity due to brain lesions modeling errors
    Vatta, F
    Bruno, P
    Inchingolo, P
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 913 - 916
  • [46] Calibration of Low Density EEG Sensor Arrays for Brain Source Localization
    Zarghami, Tahereh
    Mir, Hasan S.
    Al-Nashash, Hasan
    NEURAL INFORMATION PROCESSING, ICONIP 2012, PT I, 2012, 7663 : 331 - 338
  • [47] EEG DATA-COMPRESSION WITH SOURCE-CODING TECHNIQUES
    HINRICHS, H
    JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (05): : 417 - 423
  • [48] Source localization of sensory gating: A combined EEG and fMRI study in healthy volunteers
    Bak, Nikolaj
    Glenthoj, Birte Y.
    Rostrup, Egill
    Larsson, Henrik B.
    Oranje, Bob
    NEUROIMAGE, 2011, 54 (04) : 2711 - 2718
  • [49] BRAIN SOURCE LOCALIZATION USING A PHYSICS-DRIVEN STRUCTURED COS PARSE REPRESENTATION OF EEG SIGNALS
    Albera, L.
    Kitic, S.
    Bertin, N.
    Puy, G.
    Gribonval, Remi
    2014 IEEE INTERNATIONAL WORKSHOP ON MACHINE LEARNING FOR SIGNAL PROCESSING (MLSP), 2014,
  • [50] Localization of Epileptic Foci Using EEG Brain Mapping
    Snajdarova, Michaela
    Babusiak, Branko
    INFORMATION TECHNOLOGIES IN MEDICINE, ITIB 2016, VOL 1, 2016, 471 : 303 - 310