Life Cycle Greenhouse Gas Emissions of Crystalline Silicon Photovoltaic Electricity Generation

被引:209
作者
Hsu, David D. [1 ]
O'Donoughue, Patrick [1 ]
Fthenakis, Vasilis [2 ,3 ]
Heath, Garvin A. [1 ]
Kim, Hyung Chul [2 ,3 ]
Sawyer, Pamala [1 ]
Choi, Jun-Ki [2 ]
Turney, Damon E. [2 ]
机构
[1] Natl Renewable Energy Lab, Golden, CO 80401 USA
[2] Brookhaven Natl Lab, Upton, NY 11973 USA
[3] Columbia Univ, New York, NY USA
关键词
global warming; industrial ecology; renewable energy; life cycle assessment (LCA); meta-analysis; solar; ENERGY PAYBACK; CO2; EMISSIONS; PERFORMANCE; SYSTEM; TECHNOLOGIES; INVENTORY; TIME; COST;
D O I
10.1111/j.1530-9290.2011.00439.x
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Published scientific literature contains many studies estimating life cycle greenhouse gas (GHG) emissions of residential and utility-scale solar photovoltaics (PVs). Despite the volume of published work, variability in results hinders generalized conclusions. Most variance between studies can be attributed to differences in methods and assumptions. To clarify the published results for use in decision making and other analyses, we conduct a meta-analysis of existing studies, harmonizing key performance characteristics to produce more comparable and consistently derived results. Screening 397 life cycle assessments (LCAs) relevant to PVs yielded 13 studies on crystalline silicon (c-Si) that met minimum standards of quality, transparency, and relevance. Prior to harmonization, the median of 42 estimates of life cycle GHG emissions from those 13 LCAs was 57 grams carbon dioxide equivalent per kilowatt-hour (g CO2-eq/kWh), with an interquartile range (IQR) of 44 to 73. After harmonizing key performance characteristics (irradiation of 1,700 kilowatt-hours per square meter per year (kWh/m2/yr); system lifetime of 30 years; module efficiency of 13.2% or 14.0%, depending on module type; and a performance ratio of 0.75 or 0.80, depending on installation, the median estimate decreased to 45 and the IQR tightened to 39 to 49. The median estimate and variability were reduced compared to published estimates mainly because of higher average assumptions for irradiation and system lifetime. For the sample of studies evaluated, harmonization effectively reduced variability, providing a clearer synopsis of the life cycle GHG emissions from c-Si PVs. The literature used in this harmonization neither covers all possible c-Si installations nor represents the distribution of deployed or manufactured c-Si PVs.
引用
收藏
页码:S122 / S135
页数:14
相关论文
共 50 条
[1]  
Alsema E., 2009, IEAPVPST12012009
[2]  
Alsema EA, 2000, PROG PHOTOVOLTAICS, V8, P17, DOI 10.1002/(SICI)1099-159X(200001/02)8:1<17::AID-PIP295>3.0.CO
[3]  
2-C
[4]  
[Anonymous], 2007, ENV LIFE CYCLE INVEN
[5]  
[Anonymous], HDB PHOTOVOLTAIC SCI
[6]  
[Anonymous], 13 CIRP INT C LIF CY
[7]  
[Anonymous], 2006, ISO 14040 2006 ENV M, DOI DOI 10.1002/JTR
[8]  
Burkhardt J., 2012, J IND ECOL, DOI [10.1111/j.1530-9290.2011.00474.x, DOI 10.1111/J.1530-9290.2011.00474.X]
[9]   Quantifying Avoided Fuel Use and Emissions from Solar Photovoltaic Generation in the Western United States [J].
Denholm, Paul ;
Margolis, Robert M. ;
Milford, James M. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (01) :226-232
[10]   Life cycle inventory for electricity generation in China [J].
Di, Xianghua ;
Nie, Zuoren ;
Yuan, Baorong ;
Zuo, Tieyong .
INTERNATIONAL JOURNAL OF LIFE CYCLE ASSESSMENT, 2007, 12 (04) :217-224