Comparing Laser Peripheral Iridotomy to Cataract Extraction in Narrow Angle Eyes Using Anterior Segment Optical Coherence Tomography

被引:21
|
作者
Melese, Ephrem [1 ]
Peterson, Jeffrey R. [1 ,2 ]
Feldman, Robert M. [1 ,2 ]
Baker, Laura A. [1 ]
Bell, Nicholas P. [1 ,2 ]
Chuang, Alice Z. [2 ]
Blieden, Lauren S. [1 ,2 ]
机构
[1] Robert Cizik Eye Clin, Houston, TX 77030 USA
[2] Univ Texas Hlth Sci Ctr Houston UTHlth, McGovern Med Sch, Ruiz Dept Ophthalmol & Visual Sci, Houston, TX 77030 USA
来源
PLOS ONE | 2016年 / 11卷 / 09期
关键词
PROSPECTIVE CASE SERIES; CLOSURE GLAUCOMA PACG; CLINICAL-OUTCOMES; CHAMBER ANGLE; COEXISTING CATARACT; LENS IMPLANTATION; PHACOEMULSIFICATION; CONFIGURATION; POPULATION; PREVALENCE;
D O I
10.1371/journal.pone.0162283
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To evaluate the changes in anterior chamber angle (ACA) parameters in primary angle closure (PAC) spectrum eyes before and after cataract extraction (CE) and compare to the changes after laser peripheral iridotomy (LPI) using anterior segment optical coherence tomography (ASOCT). Methods Twenty-eight PAC spectrum eyes of 18 participants who underwent CE and 34 PAC spectrum eyes of 21 participants who underwent LPI were included. ASOCT images with 3-dimensional mode angle analysis scans were taken with the CASIA SS-1000 (Tomey Corp., Nagoya, Japan) before and after CE or LPI. Mixed-effect model analysis was used to 1) compare best-corrected visual acuity, intraocular pressure, and ACA parameters before and after CE; 2) identify and estimate the effects of potential contributing factors affecting changes in ACA parameters; and 3) compare CE and LPI treatment groups. Results The increase in average angle parameters (TISA750 and TICV750) was significantly greater after CE than LPI. TICV750 increased by 102% (2.114 [+/- 1.203] mu L) after LPI and by 174% (4.546 [+/- 1.582] mu L) after CE (P < 0.001). Change of TICV750 in the CE group was significantly affected by age (P = 0.002), race (P = 0.006), and intraocular lens power (P = 0.037). Conclusions CE results in greater anatomic changes in the ACA than LPI in PAC spectrum eyes. ASOCT may be used to follow anatomic changes in the angle after intervention.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Evaluation of changes of anterior segment parameters in patients with pseudoexfoliation syndrome after cataract surgery using anterior segment optical coherence tomography
    Wlaz, Aleksandra
    Kustra, Agnieszka
    Aung, Tin
    Zarnowski, Tomasz
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [22] A Hierarchical Cluster Analysis of Primary Angle Closure Classification Using Anterior Segment Optical Coherence Tomography Parameters
    Baek, Seunghee
    Sung, Kyung Rim
    Sun, Jae Hong
    Lee, Jong Rak
    Lee, Kyoung Sub
    Kim, Chan Yun
    Shon, Kilhwan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (01) : 848 - 853
  • [23] Comparative study of the effects of laser peripheral iridotomy and cataract surgery on anterior chamber angle parameters in primary angle closure suspect patients
    Parajuli, Sanket
    Sharma, Sadhana
    Adhikary, Rabindra
    Malla, Deekshya
    Shrestha, Ruchi
    Shakya, Prasansa
    Parajuli, Sashank
    BMJ OPEN OPHTHALMOLOGY, 2023, 8 (01):
  • [24] Acute angle closure: qualitative and quantitative evaluation of the anterior segment using anterior segment optical coherence tomography
    Moghimi, Sasan
    Zandvakil, Narges
    Vahedian, Zakieh
    Mohammadi, Massood
    Fakhraie, Ghasem
    Coleman, Anne L.
    Lin, Shan C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (07): : 615 - 622
  • [25] Anterior Segment Optical Coherence Tomography Assessment After Laser Capsulotomy in Pseudophakic Eyes With Pseudoexfoliation
    Eliacik, Mustafa
    Erdur, Sevil Karaman
    Gulkilik, Gokhan
    Ozsutcu, Mustafa
    Aras, Cengiz
    Bayramlar, Huseyin
    Aslan, Cemile Anil
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2016, 42 (05): : 318 - 321
  • [26] Modeling of gonioscopic anterior chamber angle grades based on anterior segment optical coherence tomography
    Dai, Yingying
    Zhang, Shaodan
    Shen, Meixiao
    Zhou, Yuheng
    Wang, Mengyi
    Ye, Jie
    Zhu, Dexi
    EYE AND VISION, 2020, 7 (01)
  • [27] Comparison of anterior segment morphology following prophylactic laser peripheral iridotomy in Caucasian and Chinese eyes
    Lee, Roland Y.
    Kasuga, Toshimitsu
    Cui, Qi N.
    Huang, Guofu
    He, Mingguang
    Lin, Shan C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (05): : 417 - 426
  • [28] Measurement of early changes in anterior chamber morphology after cataract extraction measured by anterior segment optical coherence tomography
    Kozue Kasai
    Genichiro Takahashi
    Koichi Kumegawa
    Murat Dogru
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2015, 253 : 1751 - 1756
  • [29] Quantitative Evaluation of Gonioscopic and EyeCam Assessments of Angle Dimensions Using Anterior Segment Optical Coherence Tomography
    Xu, Benjamin Y.
    Pardeshi, Anmol A.
    Burkemper, Bruce
    Richter, Grace M.
    Lin, Shan C.
    McKean-Cowdin, Roberta
    Varma, Rohit
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (06):
  • [30] Subclassification of Primary Angle Closure Using Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopic Parameters
    Kwon, Junki
    Sung, Kyung Rim
    Han, Seungbong
    Moon, Ye Ji
    Shin, Joong Won
    OPHTHALMOLOGY, 2017, 124 (07) : 1039 - 1047