Changes in blood volume and hematocrit during acute preoperative volume loading with 5% albumin or 6% hetastarch solutions in patients before radical hysterectomy

被引:168
作者
Rehm, M [1 ]
Haller, M [1 ]
Orth, V [1 ]
Kreimeier, U [1 ]
Jacob, M [1 ]
Dressel, H [1 ]
Mayer, S [1 ]
Brechtelsbauer, H [1 ]
Finsterer, U [1 ]
机构
[1] Univ Munich, Klinikum Grosshadern, Anasthesiol Klin, D-81377 Munich, Germany
关键词
D O I
10.1097/00000542-200110000-00011
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The impact of acute preoperative volume loading with colloids on blood volume has not been investigated sufficiently. Methods: Before surgery, in 20 patients undergoing major gynecologic procedures, volume loading was performed during anesthesia by infusing approximately 20 ml/kg of colloid at a rate of 90 ml/min (group I: 5% albumin solution; group II: 6% hetastarch solution; n = 10 each). Plasma volume (indocyanine green dilution technique), erythrocyte volume (labeling erythrocytes with fluorescein), hematocrit, total protein, and hetastarch plasma concentrations (group II) were measured before and 30 min after the end of infusion. Results: More than 1,350 ml of colloid (approximately 50% of the baseline plasma volume) were infused within 15 min. Thirty minutes after the infusion had been completed, blood volume was only 524 +/- 328 ml (group I) and 603 +/- 314 ml (group II) higher than before volume loading. The large vessel hematocrit (measured by centrifugation) dropped more than the whole body hematocrit, which was derived from double-label measurements of blood volume. Conclusions. The double-label measurements of blood volume performed showed that 30 min after the infusion of approximately 20 ml/kg of 5% albumin or 6% hetastarch solution (within 15 min), only mean 38 +/- 21% and 43 +/- 26%, respectively, of the volume applied remained in the intravascular space. Different, i.e., earlier or later, measuring points, different infusion volumes, infusion rates, plasma substitutes, or possibly different tracers for plasma volume measurement might lead to different results concerning the kinetics of fluid or colloid extravasation.
引用
收藏
页码:849 / 856
页数:8
相关论文
共 33 条
[1]  
[Anonymous], 1928, KLIN WOCHENSCHR
[2]  
BAKER KJ, 1966, P SOC EXP BIOL MED, V122, P957
[3]   PREDICTION OF BLOOD FLOW IN TUBES WITH DIAMETERS AS SMALL AS 29-MU [J].
BARBEE, JH ;
COKELET, GR .
MICROVASCULAR RESEARCH, 1971, 3 (01) :17-&
[4]  
BOLLINGER A, 1991, CIRCULATION, V83, P516
[5]  
BRULISAUER M, 1991, INT J MICROCIRC, V10, P21
[6]   CORRECTION FOR PLASMA TRAPPED IN THE RED CELL COLUMN OF THE HEMATOCRIT [J].
CHAPLIN, H ;
MOLLISON, PL .
BLOOD, 1952, 7 (12) :1227-1238
[7]   HEPARINASE TREATMENT SUGGESTS A ROLE FOR THE ENDOTHELIAL-CELL GLYCOCALYX IN REGULATION OF CAPILLARY HEMATOCRIT [J].
DESJARDINS, C ;
DULING, BR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (03) :H647-H654
[8]   MICROVESSEL HEMATOCRIT - MEASUREMENT AND IMPLICATIONS FOR CAPILLARY OXYGEN-TRANSPORT [J].
DESJARDINS, C ;
DULING, BR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (03) :H494-H503
[9]   REASSESSMENT OF RELIABILITY OF HEMATOCRIT [J].
ENGLAND, JM ;
WALFORD, DM ;
WATERS, DAW .
BRITISH JOURNAL OF HAEMATOLOGY, 1972, 23 (02) :247-&
[10]   CRITICAL EVALUATION OF METHODS FOR DETERMINATION OF BLOOD-VOLUME IN DOG [J].
FINSTERER, U ;
PRUCKSUNAND, P ;
BRECHTELSBAUER, H .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1973, 341 (01) :63-72