Use of a DVH overlay technique for quality assurance of deformable image registration-based dose accumulation

被引:11
作者
Kainz, Kristofer [1 ]
Garcia Alvarez, Juan [1 ]
Zhong, Hualiang [1 ]
Lim, Sara [1 ]
Ahunbay, Ergun [1 ]
Tai, An [1 ]
Erickson, Beth [1 ]
Lawton, Colleen [1 ]
Li, X. Allen [1 ]
机构
[1] Med Coll Wisconsin, Dept Radiat Oncol, 8701 Watertown Plank Rd, Milwaukee, WI 53226 USA
关键词
adaptive radiation therapy; deformable image registration; dose accumulation; inverse consistency error; megavoltage-computed tomography; RADIATION-THERAPY; CONSISTENCY; FRAMEWORK; DELIVERY; HEAD;
D O I
10.1002/mp.15375
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose We present a DVH overlay technique as a quality assurance (QA) metric for deformable image registration-based dose accumulation (DIR-DA). We use the technique to estimate the uncertainty in a DIR-DA for a revised treatment plan, and to compare two different DIR algorithms. Materials and methods The required inputs to the DVH overlay workflow are deformably registered primary and secondary images, primary regions-of-interest (ROIs), and secondary dose distribution. The primary ROIs were forward warped to the secondary image, the secondary dose was inversely warped to the primary image, and the DVHs for each image were compiled. Congruent DVHs imply minimal inverse consistency error (ICE) within an ROI. For a pancreas case re-planned after 21 fractions of a 29-fraction course, the workflow was used to quantify dose accumulation error attributable to ICE, based on a hybrid contour-and-intensity-based DIR. The usefulness of the workflow was further demonstrated by assessing the performance of two DIR algorithms (one free-form intensity-based, FFIB, the other using normalized correlation coefficients, NCC, over small neighborhood patches) as applied toward kilovoltage computed tomography (kVCT)-to-megavoltage computed tomography (MVCT) registration and five-fraction dose accumulation of ten male pelvis cases. Results For the re-planned pancreas case, when applying the DVH-overlay-based uncertainties the resulting accumulated dose remained compliant with all but two of the original plan objectives. Among the male pelvis cases, FFIB and NCC DIR showed good invertibility within the planning target volume (PTV), according to the DVH overlay QA results. NCC DIR exhibited better invertibility for the bladder and rectum compared with FFIB. However, compared with FFIB, NCC DIR exhibited less regional deformation for the bladder and a tendency for increased local contraction of the rectum ROI. For the five-fraction summations, ICE for the PTV V-100%Rx is comparable for both algorithms (FFIB 0.8 +/- 0.7%, NCC 0.7 +/- 0.3%). For the bladder and rectum V-70%Rx, ICE is greater for FFIB (1.8 +/- 0.7% for bladder, 1.7 +/- 0.6% for rectum) than for NCC (1.0 +/- 0.3% for bladder, 1.0 +/- 0.4% for rectum). Conclusions The DVH overlay technique identified instances in which a DIR exhibits favorable invertibility, implying low ICE in a DIR-based dose accumulation. Differences in the overlaid DVHs can also estimate dose accumulation errors attributable to ICE for given ROIs.
引用
收藏
页码:611 / 623
页数:13
相关论文
共 18 条
[1]  
Archambault Y, 2020, MED PHYS INT J, V8, P77
[2]   On the dosimetric effect and reduction of inverse consistency and transitivity errors in deformable image registration for dose accumulation [J].
Bender, Edward T. ;
Hardcastle, Nicholas ;
Tome, Wolfgang A. .
MEDICAL PHYSICS, 2012, 39 (01) :272-280
[3]   The utilization of consistency metrics for error analysis in deformable image registration [J].
Bender, Edward T. ;
Tome, Wolfgang A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (18) :5561-5577
[4]   Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task [J].
Brock, Kristy K. ;
Mutic, Sasa ;
McNutt, Todd R. ;
Li, Hua ;
Kessler, Marc L. .
MEDICAL PHYSICS, 2017, 44 (07) :E43-E76
[5]   A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets [J].
Castillo, Richard ;
Castillo, Edward ;
Guerra, Rudy ;
Johnson, Valen E. ;
McPhail, Travis ;
Garg, Amit K. ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) :1849-1870
[6]   Deformable Registration for Dose Accumulation [J].
Chetty, Indrin J. ;
Rosu-Bubulac, Mihaela .
SEMINARS IN RADIATION ONCOLOGY, 2019, 29 (03) :198-208
[7]  
Gupta V., 2014, MED PHYS, V41, P205, DOI [10.1118/1.4888261, DOI 10.1118/1.4888261]
[8]  
Jordan P., 2017, WHITE PAP ACCURAY SO, P1
[9]  
Kainz K., 2017, MKTTXPLG09170052 ACC, P18
[10]   Clinical experience with planning, quality assurance, and delivery of burst-mode modulated arc therapy [J].
Kainz, Kristofer ;
Prah, Douglas ;
Ahunbay, Ergun ;
Li, X. Allen .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05) :47-59