Implementation of the Monte Carlo Library Least-Squares (MCLLS) approach for quantification of the chlorine impurity in an on-line crude oil monitoring system

被引:9
作者
Chang, Hao Ping [1 ]
Meric, Ilker [1 ,2 ,3 ]
Sudac, Davorin [3 ]
Nad, Karlo [3 ]
Obhodas, Jasmina [3 ]
Hou, Guojing [1 ]
Zhang, Yan [1 ]
Gardner, Robin P. [1 ]
机构
[1] North Carolina State Univ, CEAR, Raleigh, NC 27695 USA
[2] Western Norway Univ Appl Sci, Dept Elect Engn, Inndalsveien 28, Bergen, Norway
[3] Rudjer Boskovic Inst, Bijenicka C 54, Zagreb 10000, Croatia
关键词
DT neutron generator; PGNAA; CEARCPG; MCLLS/MCLLSX; Crude oil; Chlorine;
D O I
10.1016/j.radphyschem.2018.05.012
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Prompt gamma-ray neutron activation analysis (PGNAA) has been widely used for elemental analysis of bulk samples as it provides an on-line, rapid and non-destructive means of performing such analysis. The Monte Carlo Library Least-Squares (MCLLS) approach is one of the methods for quantitative analysis providing elemental weight fractions via an assumption that the total prompt gamma-ray spectrum is a linear combination of the contributions from the individual prompt gamma-ray spectra of the sample constituents. For the generation of prompt gamma-ray libraries of each constituent, a specific purpose Monte Carlo code system called Center for Engineering Applications of Radioisotopes Coincidence Prompt Gamma-Ray (CEARCPG) is utilized. In this work, the focus was on detecting and measuring chlorine impurity in crude oil samples, i.e. trace amounts of chlorine. A preliminary study investigating the feasibility of PGNAA method in conjunction with the MCLLS approach for measuring trace amounts of chlorine in oil samples was performed. For this purpose, an extended version of the MCLLS approach, the so-called MCLLSX approach, was proposed and applied for the quantitative analysis. The results presented in this paper prove the feasibility of the proposed approach.
引用
收藏
页码:197 / 201
页数:5
相关论文
共 12 条
[1]   Status of the Monte Carlo library least-squares (MCLLS) approach for non-linear radiation analyzer problems [J].
Gardner, Robin P. ;
Xu, Libai .
RADIATION PHYSICS AND CHEMISTRY, 2009, 78 (10) :843-851
[2]   Single peak versus library least-squares analysis methods for the PGNAA analysis of vitrified waste [J].
Gardner, RP ;
Sood, A ;
Wang, YY ;
Liu, L ;
Guo, P ;
Gehrke, RJ .
APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) :1331-1335
[3]   NaI detector nonlinearity for PGNAA applications [J].
Gardner, RP ;
Mayo, CW .
APPLIED RADIATION AND ISOTOPES, 1999, 51 (02) :189-195
[4]  
Han X., 2006, Transactions of the American Nuclear Society, V95, P521
[5]   The Monte Carlo code CEARCPG for coincidence prompt gamma-ray neutron activation analysis [J].
Han, Xiaogang ;
Gardner, Robin P. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01) :320-325
[6]  
Han XG, 2006, NUCL SCI ENG, V155, P143
[7]   Design and geometry optimization of a conductivity probe with a vertical multiple electrode array for measuring volume fraction and axial velocity of two-phase flow [J].
Jin, N. D. ;
Xin, Z. ;
Wang, J. ;
Wang, Z. Y. ;
Jia, X. H. ;
Chen, W. P. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (04)
[8]   On the treatment of ill-conditioned cases in the Monte Carlo library least-squares approach for inverse radiation analyzers [J].
Meric, Ilker ;
Johansen, Geir A. ;
Holstad, Marie B. ;
Mattingly, John ;
Gardner, Robin P. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (05)
[9]   Produced water characterization by prompt gamma-ray neutron activation analysis [J].
Meric, Ilker ;
Johansen, Geir A. ;
Holstad, Marie B. ;
Wang, Jiaxin ;
Gardner, Robin P. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (12)
[10]   An analytical approach for treating background in spectral analysis measurements [J].
Miller, Ian ;
Holmes, Thomas W. ;
Gardner, Robin P. .
RADIATION PHYSICS AND CHEMISTRY, 2015, 116 :87-91