Non-destructive quantification of pharmaceutical tablet coatings using terahertz pulsed imaging and optical coherence tomography

被引:110
作者
Zhong, Shuncong [1 ]
Shen, Yao-Chun [1 ]
Ho, Louise [2 ,3 ]
May, Robert K. [4 ]
Zeitler, J. Axel [4 ]
Evans, Mike [3 ]
Taday, Philip F. [3 ]
Pepper, Michael [3 ]
Rades, Thomas [2 ]
Gordon, Keith C. [5 ]
Mueller, Ronny [6 ]
Kleinebudde, Peter [6 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
[2] Univ Otago, Sch Pharm, Dunedin, New Zealand
[3] TeraView Ltd, Cambridge CB4 0WS, England
[4] Univ Cambridge, Dept Chem Engn & Biotechnol, Cambridge CB2 3RA, England
[5] Univ Otago, Dept Chem, MacDiarmid Inst Adv Mat & Nanotechnol, Dunedin, New Zealand
[6] Univ Dusseldorf, Inst Pharmaceut & Biopharmaceut, D-40225 Dusseldorf, Germany
基金
中国国家自然科学基金;
关键词
Non-destructive testing; Optical coherence tomography; Terahertz pulsed imaging; Tablet coating thickness; INSPECTION;
D O I
10.1016/j.optlaseng.2010.11.003
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT) and terahertz pulsed imaging (TPI) are two powerful techniques allowing high quality cross-sectional images from within scattering media to be obtained non-destructively. In this paper, we report experimental results of using OCT and TPI for quantitatively characterizing pharmaceutical tablet coatings in the thickness range of 10-140 mu m. We found that the spectral OCT system developed in-house has an axial resolution of 0.9 mu m, and is capable of quantifying very thin coatings in the range of 10-60 mu m. The upper limit of 60 mu m within the tablet coating and core is owed to the strong scattering of OCT light, which has relatively short wavelengths in the range of 0.5-1.0 mu m. On the other hand, TPI utilizes terahertz radiation that has substantially long wavelengths in the range of hundreds of microns, and thus is less prone to the scattering problem. Consequently TPI has been demonstrated to be able to quantify thicker coatings in the range of 40-140 mu m and beyond. We concluded that OCT and TPI are two complementary analytical techniques for non-destructive and quantitative characterization of pharmaceutical tablet coatings. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:361 / 365
页数:5
相关论文
共 16 条
  • [1] Comparative study of non-destructive methods to quantify thickness of tablet coatings
    Cahyadi, C.
    Karande, A. D.
    Chan, L. W.
    Heng, P. W. S.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2010, 398 (1-2) : 39 - 49
  • [2] Nondestructive analysis of tablet coating thicknesses usign terahertz pulsed imaging
    Fitzgerald, AJ
    Cole, BE
    Taday, PF
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2005, 94 (01) : 177 - 183
  • [3] Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance
    Ho, Louise
    Mueller, Ronny
    Gordon, Keith C.
    Kleinebudde, Peter
    Pepper, Michael
    Rades, Thomas
    Shen, Yaochun
    Taday, Philip F.
    Zeitler, J. Axel
    [J]. JOURNAL OF CONTROLLED RELEASE, 2008, 127 (01) : 79 - 87
  • [4] Terahertz pulsed imaging as an analytical tool for sustained-release tablet film coating
    Ho, Louise
    Mueller, Ronny
    Gordon, Keith C.
    Kleinebudde, Peter
    Pepper, Michael
    Rades, Thomas
    Shen, Yaochun
    Taday, Philip F.
    Zeitler, J. Axel
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2009, 71 (01) : 117 - 123
  • [5] Jantzen Gwen M., 2002, VVolume 121, P501
  • [6] Optical and terahertz measurement techniques for flat-faced pharmaceutical tablets: a case study of gloss, surface roughness and bulk properties of starch acetate tablets
    Juuti, M.
    Tuononen, H.
    Prykari, T.
    Kontturi, V.
    Kuosmanen, M.
    Alarousu, E.
    Ketolainen, J.
    Myllyla, R.
    Peiponen, K-E
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (01)
  • [7] Performance of fourier domain vs. time domain optical coherence tomography
    Leitgeb, R
    Hitzenberger, CK
    Fercher, AF
    [J]. OPTICS EXPRESS, 2003, 11 (08): : 889 - 894
  • [8] Ma ZH, 2005, CHINESE PHYS LETT, V22, P1909, DOI 10.1088/0256-307X/22/8/024
  • [9] Terahertz pulsed imaging and near infrared imaging to monitor the coating process of pharmaceutical tablets
    Maurer, Lene
    Leuenberger, Hans
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2009, 370 (1-2) : 8 - 16
  • [10] Imaging Pharmaceutical Tablets with Optical Coherence Tomography
    Mauritz, Jakob M. A.
    Morrisby, Richard S.
    Hutton, Roger S.
    Legge, Coulton H.
    Kaminski, Clemens F.
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 99 (01) : 385 - 391