Micro-CT as a novel technique for 3D reconstruction of molluscan anatomy

被引:0
|
作者
Golding, Rosemary E. [1 ]
Jones, Allan S.
机构
[1] Univ Sydney, Dept Anat & Histol, Sydney, NSW 2006, Australia
[2] Univ Sydney, Electron Microscope Unit, Sydney, NSW 2006, Australia
关键词
x-ray microscopy; computed tomography; morphology; micromolluscs; soft tissue anatomy; alimentary system; buccal mass;
D O I
暂无
中图分类号
Q17 [水生生物学];
学科分类号
071004 ;
摘要
X-ray micro-CT is demonstrated to be a novel technique to examine soft-tissue anatomy and is used here to reconstruct images of molluscan soft-tissue for the first time. Two micromolluscs (> 1.8 mm diameter) were imaged using micro-CT, and then reconstructed to form 3D models of the tissues. Discrete organs of the alimentary system of large gastropods were also imaged. Osmium tetroxide and phosphomolybdic acid were identified as useful stains and a specimen preparation protocol is presented. Micro-CT is a rapid, non-destructive technique which complements and may in some circumstances replace traditional 3D reconstruction of molluscan specimens from histological sections. Micro-CT is faster and more spatially accurate than reconstruction from histological sections, but organs of a similar density are difficult to distinguish due to a lack of cellular detail.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 50 条
  • [1] Micro-CT for nondestructive 3D reconstruction of MEMS and sensors
    Sasov, A
    MEMS DESIGN, FABRICATION, CHARACTERIZATION, AND PACKAGING, 2001, 4407 : 388 - 394
  • [2] Micro-CT Guided 3D Reconstruction of Histological Images
    Nagara, Kai
    Roth, Holger R.
    Nakamura, Shota
    Oda, Hirohisa
    Moriya, Takayasu
    Oda, Masahiro
    Mori, Kensaku
    PATCH-BASED TECHNIQUES IN MEDICAL IMAGING (PATCH-MI 2017), 2017, 10530 : 93 - 101
  • [3] A novel 3D mouse embryo atlas based on micro-CT
    Wong, Michael D.
    Dorr, Adrienne E.
    Walls, Johnathon R.
    Lerch, Jason P.
    Henkelman, R. Mark
    DEVELOPMENT, 2012, 139 (17): : 3248 - 3256
  • [4] Reconstruction of the 3D Geometry of the Ossicular Chain Based on Micro-CT Imaging
    Kwacz, Monika
    Wysocki, Jaroslaw
    Krakowian, Piotr
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2012, 32 (01) : 27 - 40
  • [5] 3D micro-CT for functional genomics
    Johnson, RH
    Molthen, RM
    Hanger, CC
    Karau, KL
    Haworth, ST
    Dawson, CA
    RADIOLOGY, 1999, 213P : 194 - 194
  • [6] The Role of Micro-CT in 3D Histology Imaging
    Senter-Zapata, Michael
    Patel, Kunal
    Bautista, Pinky A.
    Griffin, Molly
    Michaelson, James
    Yagi, Yukako
    PATHOBIOLOGY, 2016, 83 (2-3) : 140 - 147
  • [7] 3D micro-CT imaging of the postmortem brain
    de Crespigny, Alex
    Bou-Reslan, Hani
    Nishimura, Merry C.
    Phillips, Heidi
    Carano, Richard A. D.
    D'Arceuil, Helen E.
    JOURNAL OF NEUROSCIENCE METHODS, 2008, 171 (02) : 207 - 213
  • [8] 3D Reconstruction of Peripheral Nerves Based on Calcium Chloride Enhanced Micro-CT Images
    Zhong, Yingchun
    Luo, Peng
    Gao, Junli
    Qi, Jian
    Li, Fang
    Yan, Liwei
    Wang, Liping
    ANALYTICAL AND QUANTITATIVE CYTOPATHOLOGY AND HISTOPATHOLOGY, 2019, 41 (05): : 159 - 168
  • [9] Novel application and validation of in vivo micro-CT to study bone modelling in 3D
    Oz, Ulas
    Ruellas, Antonio Carlos
    Westgate, Philip M.
    Cevidanes, Lucia H.
    Huja, Sarandeep S.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2019, 22 : 90 - 95
  • [10] Modeling and Reconstruction of Micro-structured 3D Chitosan/Gelatin Porous Scaffolds Using Micro-CT
    Gong Haibo
    Li Dichen
    He Jiankang
    Liu Yaxiong
    Lian Qin
    Zhao Jinna
    NUMERICAL ANALYSIS AND APPLIED MATHEMATICS, 2008, 1048 : 244 - 248