Stochastic Morphometric Model of the Balb/c Mouse Lung

被引:15
作者
Madl, Pierre [1 ]
Hofmann, Werner [1 ]
Oldham, Michael J. [2 ]
Asgharian, Rahman [3 ]
机构
[1] Salzburg Univ, Dept Mat Res & Phys, Div Phys & Biophys, A-5020 Salzburg, Austria
[2] Altria Client Serv, Richmond, VA USA
[3] Appl Res Associates, Raleigh, NC USA
来源
ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY | 2010年 / 293卷 / 10期
基金
美国国家环境保护局;
关键词
Balb/c mouse; lung morphometry; lung model; tracheobronchial airways; acinar airways; PARTICLE DEPOSITION PATTERNS; AEROSOL DEPOSITION; RAT LUNG; PREDICTIONS; INHALATION; DOSIMETRY; ACINUS;
D O I
10.1002/ar.21208
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The laboratory mouse is often used as a human surrogate in aerosol inhalation studies. Morphometric data on the tracheobronchial geometry of three in situ lung casts of the Balb/c mouse lung produced by the Air Pollution Health Effects Laboratory were analyzed in terms of probability density functions and correlations among the different airway parameters. The results of this statistical analysis reveal significant differences in diameters and branching angles between major and minor progeny branching off from the same parent airway at a given airway bifurcation. Number of bronchial airways generations along a given path, expressed by the termination probability, branching angles, and daughter-to-parent diameter ratios indicate that the location of an airway with defined linear airway dimensions within the lung is more appropriately identified by its diameter (or its parent diameter) than by an assigned generation number. We, therefore, recommend classifying the mouse lung airways by their diameters and not by generation numbers, consistent with our previous analysis of the rather monopodial structure of the rat lung (Koblinger et al., J Aerosol Med 1995;8:7-19; Koblinger and Hofmann, J Aerosol Med 1995;8:21-32). Because of lack of corresponding information on respiratory airways, a partly stochastic symmetric acinar airway model was attached to the tracheobronchial model, in which the number of acinar airways along a given path was randomly selected from a measured acinar volume distribution. The computed distributions of the geometric airway parameters and their correlations will be used for random pathway selection of inhaled particles in subsequent Monte Carlo deposition calculations. Anat Rec, 293:1766-1775, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1766 / 1775
页数:10
相关论文
共 25 条
[1]  
BUSTAD LK, 1975, NATURALLY OCCURING A
[2]  
Chameaud J., 1984, Radiation Protection Dosimetry, V7, P385
[3]  
Cross F. T., 1984, Radiation Protection Dosimetry, V7, P381
[4]   MORPHOMETRY OF THE HUMAN PULMONARY ACINUS [J].
HAEFELIBLEUER, B ;
WEIBEL, ER .
ANATOMICAL RECORD, 1988, 220 (04) :401-414
[5]   STRUCTURAL DIFFERENCES BETWEEN HUMAN AND RAT LUNGS - IMPLICATIONS FOR MONTE-CARLO MODELING OF AEROSOL DEPOSITION [J].
HOFMANN, W ;
KOBLINGER, L ;
MARTONEN, TB .
HEALTH PHYSICS, 1989, 57 :41-47
[6]  
Hofmann W, 1998, INHAL TOXICOL, V10, P557
[7]   Characterization of local particle deposition patterns in human and rat lungs by different morphometric parameters [J].
Hofmann, W ;
Bergmann, R ;
Koblinger, L .
JOURNAL OF AEROSOL SCIENCE, 1999, 30 (05) :651-667
[8]   THE EFFECT OF AGE ON LUNG STRUCTURE IN MALE BALB/CNNIA INBRED MICE [J].
KAWAKAMI, M ;
PAUL, JL ;
THURLBECK, WM .
AMERICAN JOURNAL OF ANATOMY, 1984, 170 (01) :1-21
[9]  
KLIMENT V, 1973, Folia Morphologica (Prague), V21, P59
[10]   ANALYSIS OF HUMAN-LUNG MORPHOMETRIC DATA FOR STOCHASTIC AEROSOL DEPOSITION CALCULATIONS [J].
KOBLINGER, L ;
HOFMANN, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (06) :541-556