An X-ray beam position monitor based on the photoluminescence of helium gas

被引:12
作者
Revesz, P [1 ]
White, JA [1 ]
机构
[1] Cornell Univ, Cornell High Energy Synchrotron Source, Ithaca, NY 14850 USA
基金
美国国家科学基金会;
关键词
beam position monitor; synchrotron X-rays; helium gas photo luminescence;
D O I
10.1016/j.nima.2004.11.040
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method for white beam position monitoring for both bend magnet and wiggler synchrotron X-ray radiation has been developed. This method utilizes visible light luminescence generated as a result of ionization by the intense X-ray flux. In video beam position monitors (VBPMs), the luminescence of helium gas at atmospheric pressure is observed through a view port using a CCD camera next to the beam line. The beam position, profile, integrated intensity and FWHM are calculated from the distribution of luminescence intensity in each captured image by custom software. Misalignment of upstream apertures changes the image profile making VBPMs helpful for initial alignment of upstream beam line components. VBPMs can thus provide more information about the X-ray beam than most beam position monitors (BPMs). A beam position calibration procedure, employing a tilted plane-parallel glass plate placed in front of the camera lens, has also been developed. The accuracy of the VBPM system was measured during a bench-top experiment to be better than 1 mu m. The He-luminescence-based VBPM system has been operative on three CHESS beam lines (F hard-bend and wiggler, A-line wiggler and G-line wiggler) for about a year. The beam positions are converted to analog voltages and used as feedback signals for beam stabilization. In our paper we discuss details of VBPM construction and describe further results of its performance. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:470 / 479
页数:10
相关论文
共 15 条
  • [1] ARTEMIEV AN, EPAC98
  • [2] Ausset P., 2002, P 8 EUR PART ACC C E, P1840
  • [3] CAMAS J, 1999, P 4 EUR WORKSH DIAGN, P103
  • [4] A FRAME GRABBER RELATED ERROR IN SUBPIXEL TARGET LOCATION
    CLARKE, TA
    [J]. PHOTOGRAMMETRIC RECORD, 1995, 15 (86) : 315 - 322
  • [5] GUSTAFSSON A, LITHISYR2004 DEP EL
  • [6] HOLLDACK K, 1992, REV SCI INSTRM, V66, P1889
  • [7] Synchrotron radiation parameters registration using beam cross-section image detector: The first experiments
    Ioudin, L
    Mikhailov, V
    Rezvov, V
    Sklyarenko, V
    Artemev, A
    Peredkov, S
    Rakhimbabev, T
    Lemonnier, M
    Megtert, S
    Roulliay, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 405 (2-3) : 265 - 268
  • [8] COMPACT HIGH-FLUX PHOTON-BEAM POSITION MONITOR
    JOHNSON, ED
    OVERSLUIZEN, T
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) : 1947 - 1950
  • [9] MITSHUHASHI T, 1992, REV SCI INSTRUM, V63, P543
  • [10] SCHULZEBRIESE C, 2000, PSI SCI REPORT 2000, V7