Boron isotopic ratio by electrospray mass spectra of tetrafluoroborate - Part 1. Instrumental conditions, data acquisition, memory effect, and ion stability

被引:10
作者
Moraes, MCB [1 ]
Neto, JGAB [1 ]
do Lago, CL [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, BR-05508900 Sao Paulo, Brazil
关键词
D O I
10.1039/b103089m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of electrospray mass spectrometry (ES-MS) of tetrafluoroborate solutions is proposed for the determination of the boron isotopic ratio (B-10/B-11). When a mixture of methanol and water is used as the solvent and a neutral to alkaline medium is kept, spectra obtained at mild electrospray conditions show free-of-interference peaks with base-line resolution in the region of m/z 86 and 87, which corresponds to (BF4-)-B-10 and (BF4-)-B-11. The study was carried out on a quadrupolar mass spectrometer Platform II (Micromass, UK). To minimize the memory effect in the ion source, the original pepper pot counter electrode was substituted by a cross-flow counter electrode. This geometry reduces the memory effect, but a cleaning process based on mannitol injection assures a suitable background level. Occasional corona discharge corrupts the numerical results, thus median and median of absolute deviations were used as central tendency and dispersion estimators, respectively, because spikes and outliers do not affect them. The influences of the source and detector voltages and the gas flows over the isotopic ratio were investigated. No systematic effect was observed, but there are mass discrimination and drift that were corrected by successive injections of a solution of boric acid NIST 951 converted to sodium tetrafluoroborate. Common ions such as K+, Na+, Mg2+, Ca2+, SO42-, Br- and Cl- do not cause significant isobaric interference and isotopic fractionation. The isotopic ratio precision obtained for 5 min injection of 100 mu mol L-1 boron solution at 10 muL min(-1) was typically 0.4 parts per thousand, which is comparable to those from inductively coupled plasma (ICP-MS) and thermal ionization mass spectrometry (TIMS).
引用
收藏
页码:1259 / 1265
页数:7
相关论文
共 21 条
[1]   BORON ISOTOPE ANALYSIS - A REVIEW [J].
AGGARWAL, JK ;
PALMER, MR .
ANALYST, 1995, 120 (05) :1301-1307
[2]   Elimination of boron memory effect in inductively coupled plasma-mass spectrometry by addition of ammonia [J].
Al-Ammar, A ;
Gupta, RK ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (07) :1077-1084
[3]   Improving boron isotope ratio measurement precision with quadrupole inductively coupled plasma-mass spectrometry [J].
Al-Ammar, A ;
Reitznerová, E ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (12) :1861-1867
[4]   Elimination of boron memory effect in inductively coupled plasma-mass spectrometry by ammonia gas injection into the spray chamber during analysis [J].
Al-Ammar, AS ;
Gupta, RK ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (06) :629-635
[5]   Boron isotopic analysis of natural fresh and saline waters by negative thermal ionization mass spectrometry [J].
Barth, S .
CHEMICAL GEOLOGY, 1997, 143 (3-4) :255-261
[6]   IDENTIFICATION OF GROUNDWATER SOLUTE SOURCES USING BORON ISOTOPIC COMPOSITION [J].
BASSETT, RL ;
BUSZKA, PM ;
DAVIDSON, GR ;
CHONGDIAZ, D .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (12) :2915-2922
[7]   Boron isotope ratio measurements with a double-focusing magnetic sector ICP mass spectrometer for tracing anthropogenic input into surface and ground water [J].
Gäbler, HE ;
Bahr, A .
CHEMICAL GEOLOGY, 1999, 156 (1-4) :323-330
[9]  
Heumann K.G., 1998, INORGANIC MASS SPECT, P301
[10]   MASS SPECTROMETRIC ANALYSIS OF BORON TRIFLUORIDE [J].
HORTON, JC .
ANALYTICAL CHEMISTRY, 1966, 38 (02) :198-&