Template-based automation of treatment planning in advanced radiotherapy: a comprehensive dosimetric and clinical evaluation

被引:63
作者
Cilla, Savino [1 ]
Ianiro, Anna [1 ]
Romano, Carmela [1 ]
Deodato, Francesco [2 ]
Macchia, Gabriella [2 ]
Buwenge, Milly [3 ]
Dinapoli, Nicola [4 ]
Boldrini, Luca [4 ]
Morganti, Alessio G. [3 ]
Valentini, Vincenzo [2 ,4 ]
机构
[1] Univ Cattolica Sacro Cuore, Fdn Ric & Cura Giovanni Paolo II, Med Phys Unit, Campobasso, Italy
[2] Univ Cattolica Sacro Cuore, Fdn Ric & Cura Giovanni Paolo II, Radiat Oncol Unit, Campobasso, Italy
[3] DIMES Univ Bologna, Osped S Orsola Malpighi, Radiat Oncol Dept, Bologna, Italy
[4] Fdn Policlin Univ A Gemelli, IRCCS, UOC Radioterapia Oncolog, Dipartimento Diagnost Immagini Radioterapia Oncol, Rome, Italy
关键词
VOLUMETRIC-MODULATED ARC; MULTICRITERIA OPTIMIZATION; THERAPY; PROSTATE; QUALITY; CANCER; HEAD; NECK; SYSTEM; IMRT;
D O I
10.1038/s41598-019-56966-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Despite the recent advanced developments in radiation therapy planning, treatment planning for head-neck and pelvic cancers remains challenging due to large concave target volumes, multiple dose prescriptions and numerous organs at risk close to targets. Inter-institutional studies highlighted that plan quality strongly depends on planner experience and skills. Automated optimization of planning procedure may improve plan quality and best practice. We performed a comprehensive dosimetric and clinical evaluation of the Pinnacle(3) AutoPlanning engine, comparing automatically generated plans (AP) with the historically clinically accepted manually-generated ones (MP). Thirty-six patients (12 for each of the following anatomical sites: head-neck, high-risk prostate and endometrial cancer) were re-planned with the AutoPlanning engine. Planning and optimization workflow was developed to automatically generate "dual-arc" VMAT plans with simultaneously integrated boost. Various dose and dose-volume parameters were used to build three metrics able to supply a global Plan Quality Index evaluation in terms of dose conformity indexes, targets coverage and sparing of critical organs. All plans were scored in a blinded clinical evaluation by two senior radiation oncologists. Dose accuracy was validated using the PTW Octavius-4D phantom together with the 1500 2D-array. Autoplanning was able to produce high-quality clinically acceptable plans in all cases. The main benefit of Autoplanning strategy was the improvement of overall treatment quality due to significant increased dose conformity and reduction of integral dose by 6-10%, keeping similar targets coverage. Overall planning time was reduced to 60-80 minutes, about a third of time needed for manual planning. In 94% of clinical evaluations, the AP plans scored equal or better to MP plans. Despite the increased fluence modulation, dose measurements reported an optimal agreement with dose calculations with a gamma-pass-rate greater than 95% for 3%(global)-2 mm criteria. Autoplanning engine is an effective device enabling the generation of VMAT high quality treatment plans according to institutional specific planning protocols.
引用
收藏
页数:13
相关论文
共 38 条
[1]   QUANTITATIVE ANALYSES OF NORMAL TISSUE EFFECTS IN THE CLINIC (QUANTEC): AN INTRODUCTION TO THE SCIENTIFIC ISSUES [J].
Bentzen, Soren M. ;
Constine, Louis S. ;
Deasy, Joseph O. ;
Eisbruch, Avi ;
Jackson, Andrew ;
Marks, Lawrence B. ;
Ten Haken, Randall K. ;
Yorke, Ellen D. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03) :S3-S9
[2]   Guidelines for primary radiotherapy of patients with prostate cancer [J].
Boehmer, Dirk ;
Maingon, Philippe ;
Poortmans, Philip ;
Baron, Marie-Helene ;
Miralbell, Raymond ;
Remouchamps, Vincent ;
Scrase, Christopher ;
Bossi, Alberto ;
Bolla, Michel .
RADIOTHERAPY AND ONCOLOGY, 2006, 79 (03) :259-269
[3]  
Buschmann M, 2018, STRAHLENTHER ONKOL, V194, P333, DOI 10.1007/s00066-017-1246-2
[4]   Advanced optimization methods for whole pelvic and local prostate external beam therapy [J].
Buschmann, Martin ;
Seppenwoolde, Yvette ;
Wiezorek, Tilo ;
Weibert, Kirsten ;
Georg, Dietmar .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (03) :465-473
[5]   Comparison of Planning Quality and Efficiency Between Conventional and Knowledge-based Algorithms in Nasopharyngeal Cancer Patients Using Intensity Modulated Radiation Therapy [J].
Chang, Amy T. Y. ;
Hung, Albert W. M. ;
Cheung, Fion W. K. ;
Lee, Michael C. H. ;
Chan, Oscar S. H. ;
Philips, Helen ;
Cheng, Yung-Tang ;
Ng, Wai-Tong .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (03) :981-990
[6]   Assessing the feasibility of volumetric-modulated arc therapy using simultaneous integrated boost (SIB-VMAT): An analysis for complex head-neck, high-risk prostate and rectal cancer cases [J].
Cilia, Savino ;
Deodato, Francesco ;
Digesu, Cinzia ;
Macchia, Gabriella ;
Picardi, Vincenzo ;
Ferro, Marica ;
Sallustio, Giuseppina ;
De Spirito, Marco ;
Piermattei, Angelo ;
Morganti, Alessio G. .
MEDICAL DOSIMETRY, 2014, 39 (01) :108-116
[7]   Improved planning time and plan quality through multicriteria optimization for intensity-modulated radiotherapy [J].
Craft, David L. ;
Hong, Theodore S. ;
Shih, Helen A. ;
Bortfeld, Thomas R. .
International Journal of Radiation Oncology Biology Physics, 2012, 82 (01)
[8]  
Della Gala G, 2017, STRAHLENTHER ONKOL, V193, P402, DOI 10.1007/s00066-017-1121-1
[9]   Conformity index:: A review [J].
Feuvret, L ;
Noël, G ;
Mazeron, JJ ;
Bey, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :333-342
[10]   Evaluation of a commercial automatic treatment planning system for liver stereotactic body radiation therapy treatments [J].
Gallio, Elena ;
Giglioli, Francesca Romana ;
Girardi, Andrea ;
Guarneri, Alessia ;
Ricardi, Umberto ;
Ropolo, Roberto ;
Ragona, Riccardo ;
Fiandra, Christian .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 46 :153-159