A Potentiometric Sensor for Ketoprofen Based on a β-Cyclodextrin Derivative

被引:4
作者
Lenik, Joanna [1 ]
Lyszczek, Renata [2 ]
机构
[1] Maria Curie Sklodowska Univ Lublin, Dept Analyt Chem, Inst Chem Sci, Fac Chem, Lublin, Poland
[2] Maria Curie Sklodowska Univ Lublin, Inst Chem Sci, Dept Gen Coordinat & Crystallog Chem, Fac Chem, Lublin, Poland
关键词
beta-cyclodextrins; glassy carbon electrode; inclusion complexes; ketoprofen selective electrode; IR spectroscopy; thermal analysis; ION-SELECTIVE ELECTRODES; PHARMACEUTICAL FORMULATIONS; INJECTION; HYDROCHLORIDE; DICLOFENAC; IBUPROFEN; IONOPHORE;
D O I
10.1134/S1061934822020058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thepreparation of Ag/AgCl inner electrode in the polymer layer (coated wire electrode) and glassy carbon electrodes for ketoprofen (3-benzoyl-alpha-methylbenzeneacetic acid) was described. The polymer membranes for both electrodes are based on beta-cyclodextrin derivatives. Inclusion complexes of ketoprofen with selected cyclodextrins were studied using IR spectroscopy and thermal analysis. The optimal membrane with heptakis-(2,3,6-tri-O-benzoyl)-beta-cyclodextrin was characterized by the Nernstian slope of 59.1 mV/decade over the linear range of 5 x 10(-5)-1.0 x 10(-2) M, detection limit of 1.2 x 10(-5) M, and response time of 10 s. It can be used in the pH range of 5.0-9.0 for 24 months without any considerable deterioration. Incorporation of beta-cyclodextrins improved the electrode s7ensitivity, limit of detection, and selectivity toward ketoprofen ions from several inorganic and organic interfering ions due to non-covalent interactions (host molecule-guest molecule). The attractive qualities of the ketoprofen sensor are low cost, comfortable application for 3-benzoyl-alpha-methylbenzeneacetic acid determination in pharmaceuticals with good precision and accuracy.
引用
收藏
页码:246 / 256
页数:11
相关论文
共 47 条
[1]   Ionophore-based potentiometric PVC membrane sensors for determination of phenobarbitone in pharmaceutical formulations [J].
Alrabiah, Haitham ;
Al-Majed, Abdulrahman ;
Abounassif, Mohammed ;
Mostafa, Gamal A. E. .
ACTA PHARMACEUTICA, 2016, 66 (04) :503-514
[2]  
[Anonymous], 2006, MERCK INDEX, Vfourteenth
[3]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[4]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[5]   The safety of ketoprofen in different ages [J].
Carbone, Claudia ;
Rende, Pierandrea ;
Comberiati, Pasquale ;
Carnovale, Domenico ;
Mammi, Maria ;
De Sarro, Giovambattista .
JOURNAL OF PHARMACOLOGY & PHARMACOTHERAPEUTICS, 2013, 4 (05) :S99-S103
[6]   Cyclodextrins in drug delivery: An updated review [J].
Challa, R ;
Ahuja, A ;
Ali, J ;
Khar, RK .
AAPS PHARMSCITECH, 2005, 6 (02)
[7]  
Choi S.-H., 2001, Anal. Sci./Suppl., V17, P785
[8]  
de Boer T, 2000, ELECTROPHORESIS, V21, P3220, DOI 10.1002/1522-2683(20000901)21:15<3220::AID-ELPS3220>3.0.CO
[9]  
2-X
[10]   Ag/AgCl ion-selective electrodes in neutral and alkaline environments containing interfering ions [J].
Femenias, Yurena Segui ;
Angst, Ueli ;
Caruso, Francesco ;
Elsener, Bernhard .
MATERIALS AND STRUCTURES, 2016, 49 (07) :2637-2651