Accuracy of navigated surgery of the pelvis after surface matching with an a-mode ultrasound probe

被引:15
作者
Oszwald, M. [1 ]
Citak, M. [1 ]
Kendoff, D. [1 ]
Kowal, J. [3 ]
Amstutz, C. [3 ]
Kirchhoff, T. [2 ]
Nolte, L. P. [3 ]
Krettek, C. [1 ]
Huefner, T. [1 ]
机构
[1] Hannover Med Sch, Trauma Dept, D-30625 Hannover, Germany
[2] Hannover Med Sch, Dept Radiol, D-30625 Hannover, Germany
[3] MEM Inst Surg Technol & Biomech, CH-3014 Bern, Switzerland
关键词
computer-assisted surgery; navigation; surface-matching; a-mode ultrasound; pelvis;
D O I
10.1002/jor.20551
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computer-aided surgery (CAS) allows for real-time intraoperative feedback resulting in increased accuracy, while reducing intraoperative radiation. CAS is especially useful for the treatment of certain pelvic ring fractures, which necessitate the precise placement of screws. Flouroscopy-based CAS modules have been developed for many orthopedic applications. The integration of the isocentric flouroscope even enables navigation using intraoperatively acquired three-dimensional (3D) data, though the scan volume and imaging quality are limited. Complicated and comprehensive pathologies in regions like the pelvis can necessitate a CT-based navigation system because of its larger field of view. To be accurate, the patient's anatomy must be registered and matched with the virtual object (CT data). The actual precision within the region of interest depends on the area of the bone where surface matching is performed. Conventional surface matching with a solid pointer requires extensive soft tissue dissection. This contradicts the primary purpose of CAS as a minimally invasive alternative to conventional surgical techniques. We therefore integrated an a-mode ultrasound pointer into the process of surface matching for pelvic surgery and compared it to the conventional method. Accuracy measurements were made in two pelvic models: a foam model submerged in water and one with attached porcine muscle tissue. Three different tissue depths were selected based on CT scans of 30 human pelves. The ultrasound pointer allowed for registration of virtually any point on the pelvis. This method of surface matching could be successfully integrated into CAS of the pelvis. (C) 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:860 / 864
页数:5
相关论文
共 15 条
  • [1] AMIN DV, 2001, COMPUT AIDED SURG, V6, P48
  • [2] A-mode ultrasound-based registration in computer-aided surgery of the skull
    Amstutz, C
    Caversaccio, M
    Kowal, J
    Bächler, R
    Nolte, LP
    Häusler, R
    Styner, M
    [J]. ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2003, 129 (12) : 1310 - 1316
  • [3] BAECHLER R, 2000, PHILOSPHLISCH NATURW, P114
  • [4] BAECHLER R, 2001, COMPUT AIDED SURG, V6, P143, DOI DOI 10.3109/10929080109146000
  • [5] BERLEMANN U, 2002, UNFALLCHIRURGISCHE K, P93
  • [6] Heger S, 2002, Biomed Tech (Berl), V47 Suppl 1 Pt 1, P61, DOI 10.1515/bmte.2002.47.s1a.61
  • [7] User-interactive registration of bone with A-mode ultrasound
    Heger, S
    Portheine, F
    Ohnsorge, JAK
    Schkommodau, E
    Radermacher, K
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2005, 24 (02): : 85 - 95
  • [8] HUFNER T, 2001, UNFALLCHIRURGISCHE K, P145
  • [9] Lavallee S, 1996, COMPUTER INTEGRATED, P77
  • [10] Sadowsky Ofri, 2002, Comput Aided Surg, V7, P223, DOI 10.1002/igs.10048