Robust, coordinated control of SSO in wind-integrated power system

被引:7
|
作者
Wang, Tong [1 ]
Yang, Jing [1 ]
Padhee, Malhar [2 ]
Bi, Jingtian [3 ]
Pal, Anamitra [2 ]
Wang, Zengping [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing, Peoples R China
[2] Arizona State Univ, Sch Elect Comp & Energy Engn, Tempe, AZ USA
[3] China Elect Power Res Inst, Power Syst Dept, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
oscillations; asynchronous generators; linear matrix inequalities; rotors; control system synthesis; damping; power generation control; robust control; wind power plants; power system stability; power convertors; H-2; control; H-infinity control; centralised control; multiple wind farms; damping control strategy; regional pole placement; convex polytopic theory; centralised controller; coordinated controller; damping signal; active power; reactive power modulation; doubly fed induction generators; wind-integrated power system; robust control methodology; sub-synchronous oscillations; SSOs; mixed H2-H infinity control; rotor-side converter; FED INDUCTION GENERATOR; SMALL-SIGNAL STABILITY; DAMPING CONTROL; RENEWABLE ENERGY; DESIGN; DFIG; OSCILLATION; FARM;
D O I
10.1049/iet-rpg.2019.0410
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study presents a robust, coordinated control methodology for damping sub-synchronous oscillations (SSOs) while considering power output variations from multiple wind farms. The proposed damping control strategy utilises the mixed H-2/H-infinity control with regional pole placement to suppress the oscillations. For ensuring applicability over a wider operating range, the convex polytopic theory is utilised by using different operating points as the vertices of a convex polytope. The centralised, coordinated controller for damping SSOs is designed using linear matrix inequalities. Furthermore, unmeasurable state variables, if present, are represented by corresponding output variables. The damping signal is implemented as active power and reactive power modulation of the rotor-side converter of the doubly fed induction generators. A 4-machine, 2-area system and a 39-machine New England system are used to demonstrate the performance of the proposed control. The simulation results show that the polytopic controller can not only provide requisite damping to the SSO modes of interest, but also has good control performance when the wind power outputs change over a wide range.
引用
收藏
页码:1031 / 1043
页数:13
相关论文
共 50 条
  • [21] Robust coordinated control for damping low frequency oscillations in high wind penetration power system
    Gupta, Abhilash Kumar
    Verma, Kusum
    Niazi, Khaleequr Rehman
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (05)
  • [22] Defining SSO Power and Characterizing SSO Propagation in Power System With Wind Farms Integration
    Yang, Na
    Ma, Wenda
    Wang, Xitian
    Xie, Da
    Gu, Chenghong
    Zhao, Dawei
    Zhang, Yu
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (04) : 3531 - 3540
  • [23] A Comprehensive Review on Voltage Stability in Wind-Integrated Power Systems
    Malik, Farhan Hameed
    Khan, Muhammad Waleed
    Rahman, Tauheed Ur
    Ehtisham, Muhammad
    Faheem, Muhammad
    Haider, Zunaib Maqsood
    Lehtonen, Matti
    ENERGIES, 2024, 17 (03)
  • [24] Time-Scale Modeling of Wind-Integrated Power Systems
    Chandra, Souvik
    Gayme, Dennice F.
    Chakrabortty, Aranya
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (06) : 4712 - 4721
  • [25] Efficient Stochastic Scheduling for Simulation of Wind-Integrated Power Systems
    Sturt, Alexander
    Strbac, Goran
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2012, 27 (01) : 323 - 334
  • [26] Security constrained economic dispatch of wind-integrated power system considering optimal system state selection
    Ma, Yanfeng
    Hao, Yi
    Zhao, Shuqiang
    Bi, Huijing
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (01) : 27 - 36
  • [27] Optimal Transmission Entry Capacity in Wind-Integrated Power Systems
    Uzuncan, Ezgi
    Hesamzadeh, Mohammad R.
    2014 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON 2014), 2014, : 1467 - 1473
  • [28] A Robust Coordinated Control Method for BESS to Smooth Wind Power Generation
    Li, Zhonghao
    Jain, Harshit
    Zhang, Peichao
    Luo, Xu
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [29] Decentralized approach for security enhancement of wind-integrated energy systems coordinated with energy storages
    Ebrahimi, Hossein
    Abapour, Mehdi
    Mohammadi-Ivatloo, Behnam
    Golshannavaz, Sajjad
    Yazdaninejadi, Amin
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (04) : 5006 - 5027
  • [30] An improved neuro-adaptive-optimal control for oscillation damping in wind-integrated power systems
    Jamsheed, Faisal
    Iqbal, Sheikh Javed
    OPTIMAL CONTROL APPLICATIONS & METHODS, 2023, 44 (02): : 885 - 904