Switching transient analysis for low voltage distribution cable

被引:0
作者
Mishra, Sanhita [1 ]
Swain, Sarat Chandra [1 ]
Dash, Ritesh [2 ]
机构
[1] KIIT Deemed Univ, Sch Elect Engn, Bhubaneswar, India
[2] REVA Univ, Sch EEE, Bengaluru, India
关键词
experimental setup; low voltage underground cable; switching transient; DWT analysis; POWER TRANSMISSION; DANISH EXPERIENCE; PARAMETERS; SYSTEMS; CLASSIFICATION; SIMULATION;
D O I
10.1515/eng-2022-0004
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Low voltage cable is primarily connected from the transmission system to several household applications. It is quite common that switching transient in the power system during the energization of the high voltage and low voltage cables have a very crippling effect on the cable as well as the power system components. Hence, an experiment has been performed in the laboratory with a low voltage cable-connected motor system. The experimental results have been validated in the simulation platform, and they are capable of predicting the transient behavior during power cable energization. The effect of transients on power cables during the energization of devices has been investigated in this study in the form of voltage, current, and frequency. Discrete wavelet transform is implemented for the decomposition of the transient current. The generated approximation signal is used to quantify the severity during switching transient condition.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 38 条
[1]  
Agrawal MS., 1998, SWITCHING TRANSIENTS, P446
[2]   Effects of cable insulations' physical and geometrical parameters on sheath transients and insulation losses [J].
Alatawneh, Natheer .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 110 :95-106
[3]   Modeling and simulation of a HV shielded underground three-phase cable in both normal and default states: Application to the 150 kV connection between Taparoura, Sidimansour and Tyna substations in Sfax-Tunisia [J].
Aloui, Thameur ;
Ben Amar, Fathi ;
Abdallah, Hsan Hadj .
ELECTRIC POWER SYSTEMS RESEARCH, 2016, 141 :91-99
[4]  
Ametani A., 1992, Electrical Engineering in Japan, V112, P117, DOI 10.1002/eej.4391120213
[5]   High voltage AC underground cable systems for power transmission - A review of the Danish experience, part 1 [J].
Bak, Claus Leth ;
da Silva, F. Faria .
ELECTRIC POWER SYSTEMS RESEARCH, 2016, 140 :984-994
[6]   High Voltage AC underground cable systems for power transmission - A review of the Danish experience: Part 2 [J].
Bak, Claus Leth ;
da Silva, F. Faria .
ELECTRIC POWER SYSTEMS RESEARCH, 2016, 140 :995-1004
[7]   Categorization and analysis of power system transients [J].
Bollen, MHJ ;
Styvaktakis, E ;
Gu, IYH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) :2298-2306
[8]  
Chakraborty Ananya, 2017, 2017 International Conference on Energy, Communication, Data Analytics and Soft Computing (ICECDS), P346, DOI 10.1109/ICECDS.2017.8390084
[9]   A sparse representation based approach for recognition of power system transients [J].
Chakraborty, Soumi ;
Chatterjee, Amitava ;
Goswami, Swapan Kumar .
ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2014, 30 :137-144
[10]  
Da Silva FF., 2013, Electromagnetic Transients in Power Cables, DOI [10.1007/978-1-4471-5236-1, DOI 10.1007/978-1-4471-5236-1]