Thermomechanical characteristics of 500-m HTS power cable

被引:12
作者
Ichikawa, M [1 ]
Kanegami, M
Okamoto, T
Akita, S
Yagi, M
Kimura, A
机构
[1] Cent Res Inst Elect Power Ind, Yokosuka, Kanagawa 2400196, Japan
[2] Furukawa Elect Corp Ltd, Chiba 2908555, Japan
[3] Engn Res Assoc Superconduct Generat Equipment & M, Osaka 5300047, Japan
关键词
offset; superconducting cable; thermal contraction;
D O I
10.1109/TASC.2005.849284
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 500-m single-core high temperature superconducting (HTS) cable system has been constructed and tested in Yokosuka area, CRIEPI, by CRIEPI, The Furukawa Electric and Super-GM. In the actual power grid, the HTS cable distance extends sometimes several km. And has to be cooled down from about room temperature to liquid nitrogen temperature. As, the HTS cable is contracted and suffers mechanical stress. In the case of the long distance HTS cable, it remains a major development issue. The HTS cable constructed in this test system has an offset section for absorbing the thermal contraction. In this paper, we describe the validity of that offset section and the thermomechanical characteristics on the cooldown and warm-up test. The offset functioned successfully as designed.
引用
收藏
页码:1771 / 1774
页数:4
相关论文
共 6 条
[1]  
CHIFUKU K, 1976, FURUKAWA ELECT REV
[2]   Electric properties of a 66 kV 3-core superconducting power cable system [J].
Honjo, S ;
Shimodate, M ;
Takahashi, Y ;
Masuda, T ;
Yumura, H ;
Suzawa, C ;
Isojima, S ;
Suzuki, H .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) :1952-1955
[3]  
Moore T, 1999, EPRI J, V24, P8
[4]   Test results of a 30 m high-Tc superconducting power cable [J].
Mukoyama, S ;
Hirano, H ;
Yagi, M ;
Kimura, H ;
Kikuchi, A .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) :1926-1929
[5]   The current test results for two models of HTS cables on CASAT project [J].
Sytnikov, VE ;
Dolgosheev, PI ;
Soloviev, MG ;
Belij, DI ;
Nieto, L ;
Perez, A ;
Gonzalez, A ;
Maya, M ;
Ortiz, F ;
Falcony, C ;
Jergel, M ;
Morales, A .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) :1964-1967
[6]   Thermo-mechanical properties of a 66 kV superconducting power cable system [J].
Watanabe, M ;
Masuda, T ;
Ashibe, Y ;
Hirose, M ;
Isojima, S ;
Honjo, S ;
Uchiyama, T ;
Shimodate, M ;
Takahashi, Y ;
Suzuki, H .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) :1956-1959