Estimating the global order of the fMRI noise model

被引:11
作者
Gautama, T [1 ]
Van Hulle, MM [1 ]
机构
[1] Katholieke Univ Leuven, Lab Neuro Psychofysiol, B-3000 Louvain, Belgium
关键词
prewhitening; autocorrelation; autoregressive; model order selection;
D O I
10.1016/j.neuroimage.2005.03.015
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
One of the major issues in GLM-based fMRI analysis techniques is the presence of temporal autocorrelations in the residual signal after regression. A possible correction method is that of prewhitening, which fits an autoregressive (or other) model to the residual and uses the expected temporal autocorrelations of the model to transform the data and design matrix such that the residual becomes white noise. In this article. a method is introduced to estimate the global autoregressive model order of a data set, based on the residuals after regression. The proposed global standardized partial autocorrelation (SPAC) method tests whether the spatial profile of partial autocorrelations at a certain lag is random, and uses random field theory to account for the spatial correlations typical for fMRI data. It is tested both on synthetic and fMRI data, and is compared to two traditional techniques for model order estimation. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:1211 / 1217
页数:7
相关论文
共 22 条
[1]  
Box G. E. P, 1970, TIME SERIES ANAL FOR
[2]   Autoregressive model order selection by a finite sample estimator for the Kullback-Leibler discrepancy [J].
Broersen, PMT ;
Wensink, HE .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1998, 46 (07) :2058-2061
[3]   Statistical methods of estimation and inference for functional MR image analysis [J].
Bullmore, E ;
Brammer, M ;
Williams, SCR ;
Rabehesketh, S ;
Janot, N ;
David, A ;
Mellers, J ;
Howard, R ;
Sham, P .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) :261-277
[4]  
Bullmore ET, 2001, HUM BRAIN MAPP, V12, P61, DOI 10.1002/1097-0193(200102)12:2<61::AID-HBM1004>3.0.CO
[5]  
2-W
[6]   IMPROVED ASSESSMENT OF SIGNIFICANT ACTIVATION IN FUNCTIONAL MAGNETIC-RESONANCE-IMAGING (FMRI) - USE OF A CLUSTER-SIZE THRESHOLD [J].
FORMAN, SD ;
COHEN, JD ;
FITZGERALD, M ;
EDDY, WF ;
MINTUN, MA ;
NOLL, DC .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :636-647
[7]   To smooth or not to smooth? Bias and efficiency in fMRI time-series analysis [J].
Friston, KJ ;
Josephs, O ;
Zarahn, E ;
Holmes, AP ;
Rouquette, S ;
Poline, JB .
NEUROIMAGE, 2000, 12 (02) :196-208
[8]   Optimal spatial regularisation of autocorrelation estimates in fMRI analysis [J].
Gautama, T ;
Van Hulle, MM .
NEUROIMAGE, 2004, 23 (03) :1203-1216
[9]  
Locascio JJ, 1997, HUM BRAIN MAPP, V5, P168, DOI 10.1002/(SICI)1097-0193(1997)5:3<168::AID-HBM3>3.0.CO
[10]  
2-1