Is a simplified Finite Element model of the gluteus region able to capture the mechanical response of the internal soft tissues under compression?
被引:13
|作者:
Macron, Aurelien
[1
,3
]
Pillet, Helene
[1
]
Doridam, Jennifer
[1
]
Rivals, Isabelle
[4
,5
]
Sadeghinia, Mohammad Javad
[1
,6
]
Verney, Alexandre
[2
]
Rohan, Pierre-Yves
[1
]
机构:
[1] Arts & Metiers ParisTech, Inst Biomecan Humaine Georges Charpak, 151 Bd Hop, F-75013 Paris, France
[2] CEA, LIST, Interact Robot Lab, F-91191 Gif Sur Yvette, France
[3] Univ Grenoble Alpes, CLINATEC, LETI, CEA, MINATEC Campus, F-38000 Grenoble, France
[4] Sorbonne Univ, UMRS Neurophysiol Respiratoire Expt & Clin 1158, INSERM, Paris, France
[5] PSL Res Univ, ESPCI Paris, Equipe Stat Appl, Paris, France
[6] Univ Tehran, Coll Engn, Sch Mech Engn, Tehran, Iran
关键词:
Deep Tissue Injury;
Pressure Ulcer;
Subject specific;
Buttock;
Sitting;
Finite Element analysis;
PROPHYLACTIC SACRAL DRESSINGS;
SHEAR-WAVE ELASTOGRAPHY;
SUB-DERMAL TISSUES;
MUSCLE-TISSUE;
PRESSURE ULCERS;
DEEP;
DEFORMATION;
INJURY;
DAMAGE;
ULTRASOUND;
D O I:
10.1016/j.clinbiomech.2019.10.005
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
Background: Internal soft tissue strains have been shown to be one of the main factors responsible for the onset of Pressure Ulcers and to be representative of its risk of development. However, the estimation of this parameter using Finite Element (FE) analysis in clinical setups is currently hindered by costly acquisition, reconstruction and computation times. Ultrasound (US) imaging is a promising candidate for the clinical assessment of both morphological and material parameters. Method: The aim of this study was to investigate the ability of a local FE model of the region beneath the ischium with a limited number of parameters to capture the internal response of the gluteus region predicted by a complete 3D FE model. 26 local FE models were developed, and their predictions were compared to those of the patient-specific reference FE models in sitting position. Findings: A high correlation was observed (R = 0.90, p-value < 0.01). A sensitivity analysis showed that the most influent parameters were the mechanical behaviour of the muscle tissues, the ischium morphology and the external mechanical loading. Interpretation: Given the progress of US for capturing both morphological and material parameters, these results are promising because they open up the possibility to use personalised simplified FE models for risk estimation in daily clinical routine.
引用
收藏
页码:92 / 100
页数:9