Microbial biosensor for the analysis of 2,4-dichlorophenol

被引:11
|
作者
Jantra, J
Zilouei, H
Liu, J
Guieysse, B
Thavarungkul, P
Kanatharana, P
Mattiasson, B
机构
[1] Lund Univ, Dept Biotechnol, S-22100 Lund, Sweden
[2] Prince Songkla Univ, Biophys Res Unit Biosensors & Biocurrents, Hat Yai, Songkhla, Thailand
[3] Prince Songkla Univ, Dept Chem, Fac Sci, Hat Yai, Songkhla, Thailand
[4] Prince Songkla Univ, Dept Phys, Fac Sci, Hat Yai, Songkhla, Thailand
关键词
biosensor; chlorophenol; DCP; environmental pollution;
D O I
10.1081/AL-200057192
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection cell-based biosensor was constructed for 2,4-dichlorophenol (DCP) analysis by using a Clark-type oxygen electrode as a transducer. A mixed bacterial culture capable to biodegrade DCP was immobilized between a Teflon membrane and a dialysis membrane and attached to the oxygen electrode. Optimization of the flow rate, the injection volume, the carrier buffer concentration, and pH was carried out. Under optimum conditions (100 mM phosphate buffer, pH 7.50; flow rate 0.10 mL min(-1); sample volume 100 mL), the sensor response was linear between 0.01 and 0.30 mM DCP. The detection limit was 0.02 mM DCP, and the sensor was quite stable during 5 days of operation.
引用
收藏
页码:1071 / 1083
页数:13
相关论文
共 50 条
  • [1] Bacillus cereus is a microbial decomposer of 2,4-dichlorophenol
    G. G. Matafonova
    G. S. Shirapova
    C. Zimmer
    G. -W. Kohring
    F. Giffhorn
    V. B. Batoev
    V. J. Tsyrenov
    Biology Bulletin, 2007, 34 : 442 - 445
  • [2] Bacillus cereus is a microbial decomposer of 2,4-dichlorophenol
    Matafonova, G. G.
    Shirapova, G. S.
    Zimmer, C.
    Kohring, G.-W.
    Giffhorn, F.
    Batoev, V. B.
    Tsyrenov, V. J.
    BIOLOGY BULLETIN, 2007, 34 (05) : 442 - 445
  • [4] Modelling the cathodic reduction of 2,4-dichlorophenol in a microbial fuel cell
    Luis Fernando Leon-Fernandez
    Francisco Jesús Fernandez-Morales
    José Villaseñor Camacho
    Bioprocess and Biosystems Engineering, 2022, 45 : 771 - 782
  • [5] Sensitive mediator-free tyrosinase biosensor for the determination of 2,4-dichlorophenol
    Lingmi Kong
    Shasheng Huang
    Zenglian Yue
    Bin Peng
    Mengyao Li
    Jing Zhang
    Microchimica Acta, 2009, 165 : 203 - 209
  • [6] Modelling the cathodic reduction of 2,4-dichlorophenol in a microbial fuel cell
    Fernando Leon-Fernandez, Luis
    Jesus Fernandez-Morales, Francisco
    Villasenor Camacho, Jose
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2022, 45 (04) : 771 - 782
  • [7] Sensitive mediator-free tyrosinase biosensor for the determination of 2,4-dichlorophenol
    Kong, Lingmi
    Huang, Shasheng
    Yue, Zenglian
    Peng, Bin
    Li, Mengyao
    Zhang, Jing
    MICROCHIMICA ACTA, 2009, 165 (1-2) : 203 - 209
  • [8] INHIBITION OF CATALASE BY 2,4-DICHLOROPHENOL
    VANREEN, R
    ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1954, 50 (01) : 219 - 221
  • [9] DISAPPEARANCE KINETICS OF 2,4-DICHLOROPHENOL AND 3,4-DICHLOROPHENOL IN A FLUVIAL SYSTEM
    CAREY, JH
    FOX, ME
    BROWNLEE, BG
    METCALFE, JL
    PLATFORD, RF
    CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1984, 62 (08) : 971 - 975
  • [10] Biosensor based on horseradish peroxidase modified carbon nanotubes for determination of 2,4-dichlorophenol
    Shasheng Huang
    Yongxia Qu
    Ruina Li
    Jian Shen
    Liwei Zhu
    Microchimica Acta, 2008, 162 : 261 - 268