Magnetic Equivalent Circuit Model Considering Overhang Structure of a Surface-Mounted Permanent-Magnet Motor

被引:59
作者
Yeo, Han-Kyeol [1 ]
Lim, Dong-Kuk [1 ]
Woo, Dong-Kyun [2 ]
Ro, Jong-Suk [1 ]
Jung, Hyun-Kyo [1 ]
机构
[1] Seoul Natl Univ, Creat Res Engn Dev, Brain Korea Plus 21, Seoul 151742, South Korea
[2] Yeungnam Univ, Dept Elect Engn, Gyeongbuk 712749, South Korea
关键词
Analytical method; magnetic equivalent circuit (MEC) model; overhang structure; surface-mounted permanent-magnet (SPM) motor; AIR-GAP; FLUX; MACHINES; LEAKAGE;
D O I
10.1109/TMAG.2014.2345558
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An overhang structure is used to enhance the air-gap flux density and increase the torque density of a motor. In the preliminary design stage, consideration of the overhang effect is important for a precise prediction of the performance of a motor with overhang and for the selection of the proper overhang length. The 3-D finite-element method (FEM) is essential when analyzing a motor with an overhang structure due to the asymmetry in the axial direction caused by overhang. However, it is computationally expensive and time-consuming, especially during the initial design stage. In this paper, we propose a magnetic equivalent circuit model, which considers the overhang structure of a surface-mounted permanent-magnet motor. With the proposed analytical method, the computational time is significantly reduced in the preliminary design stage. The proposed analytical model is verified with a 3-D FEM analysis.
引用
收藏
页数:4
相关论文
共 13 条
[1]   Induction Machine Modeling Approach Based on 3-D Magnetic Equivalent Circuit Framework [J].
Amrhein, Marco ;
Krein, Philip T. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (02) :339-347
[2]  
[Anonymous], BRUSHLESS PERMANENT
[3]   Magnetic equivalent circuit modelling of brushless doubly-fed induction generator [J].
Gorginpour, Hamed ;
Jandaghi, Behzad ;
Oraee, Hashem ;
Abdi, Ehsan .
IET RENEWABLE POWER GENERATION, 2014, 8 (03) :334-346
[4]   A Generalized Magnetic Circuit Modeling Approach for Design of Surface Permanent-Magnet Machines [J].
Hsieh, Min-Fu ;
Hsu, You-Chiuan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (02) :779-792
[5]   Simple nonlinear magnetic analysis for permanent-magnet motors [J].
Kano, Y ;
Kosaka, T ;
Matsui, N .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) :1205-1214
[6]   Analytical method for predicting the air-gap flux of interior-type permanent-magnet machines [J].
Mi, CT ;
Filippa, M ;
Liu, WG ;
Ma, RQ .
IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (01) :50-58
[7]   An improved magnetic equivalent circuit method for predicting the characteristics of highly saturated electromagnetic devices [J].
Moallem, M ;
Dawson, GE .
IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (05) :3632-3635
[8]   Analysis and modeling of air-gap and zigzag leakage fluxes in a surface-mounted permanent-magnet machine [J].
Qu, RH ;
Lipo, TA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (01) :121-127
[9]   An Improved Magnetic Equivalent Circuit Model for Iron-Core Linear Permanent-Magnet Synchronous Motors [J].
Sheikh-Ghalavand, B. ;
Vaez-Zadeh, S. ;
Isfahani, A. Hassanpour .
IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (01) :112-120
[10]   Analysis of flux leakage in a brushless permanent-magnet motor with embedded magnets [J].
Tsai, WB ;
Chang, TY .
IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (01) :543-547